Purpose: To perform a clinical assessment of quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) feasibility and repeatability in patients with liver metastasis, and to evaluate the extent of quantitative perfusion parameter sampling errors in 2D compared to 3D DCE-US i...

Descripción completa

Detalles Bibliográficos
Autores principales: El Kaffas, Ahmed, Sigrist, Rosa Maria Silveira, Fisher, George, Bachawal, Sunitha, Liau, Joy, Wang, Huaijun, Karanany, Alexander, Durot, Isabelle, Rosenberg, Jarrett, Hristov, Dimitre, Willmann, Jürgen K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667345/
https://www.ncbi.nlm.nih.gov/pubmed/29109773
http://dx.doi.org/10.7150/thno.20329
_version_ 1783275476081442816
author El Kaffas, Ahmed
Sigrist, Rosa Maria Silveira
Fisher, George
Bachawal, Sunitha
Liau, Joy
Wang, Huaijun
Karanany, Alexander
Durot, Isabelle
Rosenberg, Jarrett
Hristov, Dimitre
Willmann, Jürgen K.
author_facet El Kaffas, Ahmed
Sigrist, Rosa Maria Silveira
Fisher, George
Bachawal, Sunitha
Liau, Joy
Wang, Huaijun
Karanany, Alexander
Durot, Isabelle
Rosenberg, Jarrett
Hristov, Dimitre
Willmann, Jürgen K.
author_sort El Kaffas, Ahmed
collection PubMed
description Purpose: To perform a clinical assessment of quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) feasibility and repeatability in patients with liver metastasis, and to evaluate the extent of quantitative perfusion parameter sampling errors in 2D compared to 3D DCE-US imaging. Materials and Methods: Twenty consecutive 3D DCE-US scans of liver metastases were performed in 11 patients (45% women; mean age, 54.5 years; range, 48-60 years; 55% men; mean age, 57.6 years; range, 47-68 years). Pairs of repeated disruption-replenishment and bolus DCE-US images were acquired to determine repeatability of parameters. Disruption-replenishment was carried out by infusing 0.9 mL of microbubbles (Definity; Latheus Medical Imaging) diluted in 35.1 mL of saline over 8 min. Bolus consisted of intravenous injection of 0.2 mL microbubbles. Volumes-of-interest (VOI) and regions-or-interest (ROI) were segmented by two different readers in images to extract 3D and 2D perfusion parameters, respectively. Disruption-replenishment parameters were: relative blood volume (rBV), relative blood flow (rBF). Bolus parameters included: time-to-peak (TP), peak enhancement (PE), area-under-the-curve (AUC), and mean-transit-time (MTT). Results: Clinical feasibility and repeatability of 3D DCE-US using both the destruction-replenishment and bolus technique was demonstrated. The repeatability of 3D measurements between pairs of repeated acquisitions was assessed with the concordance correlation coefficient (CCC), and found to be excellent for all parameters (CCC > 0.80), except for the TP (0.74) and MTT (0.30) parameters. The CCC between readers was found to be excellent (CCC > 0.80) for all parameters except for TP (0.71) and MTT (0.52). There was a large Coefficient of Variation (COV) in intra-tumor measurements for 2D parameters (0.18-0.52). Same-tumor measurements made in 3D were significantly different (P = 0.001) than measurements made in 2D; a percent difference of up to 86% was observed between measurements made in 2D compared to 3D in the same tumor. Conclusions: 3D DCE-US imaging of liver metastases with a matrix array transducer is feasible and repeatable in the clinic. Results support 3D instead of 2D DCE US imaging to minimize sampling errors due to tumor heterogeneity.
format Online
Article
Text
id pubmed-5667345
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-56673452017-11-06 Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases El Kaffas, Ahmed Sigrist, Rosa Maria Silveira Fisher, George Bachawal, Sunitha Liau, Joy Wang, Huaijun Karanany, Alexander Durot, Isabelle Rosenberg, Jarrett Hristov, Dimitre Willmann, Jürgen K. Theranostics Research Paper Purpose: To perform a clinical assessment of quantitative three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) feasibility and repeatability in patients with liver metastasis, and to evaluate the extent of quantitative perfusion parameter sampling errors in 2D compared to 3D DCE-US imaging. Materials and Methods: Twenty consecutive 3D DCE-US scans of liver metastases were performed in 11 patients (45% women; mean age, 54.5 years; range, 48-60 years; 55% men; mean age, 57.6 years; range, 47-68 years). Pairs of repeated disruption-replenishment and bolus DCE-US images were acquired to determine repeatability of parameters. Disruption-replenishment was carried out by infusing 0.9 mL of microbubbles (Definity; Latheus Medical Imaging) diluted in 35.1 mL of saline over 8 min. Bolus consisted of intravenous injection of 0.2 mL microbubbles. Volumes-of-interest (VOI) and regions-or-interest (ROI) were segmented by two different readers in images to extract 3D and 2D perfusion parameters, respectively. Disruption-replenishment parameters were: relative blood volume (rBV), relative blood flow (rBF). Bolus parameters included: time-to-peak (TP), peak enhancement (PE), area-under-the-curve (AUC), and mean-transit-time (MTT). Results: Clinical feasibility and repeatability of 3D DCE-US using both the destruction-replenishment and bolus technique was demonstrated. The repeatability of 3D measurements between pairs of repeated acquisitions was assessed with the concordance correlation coefficient (CCC), and found to be excellent for all parameters (CCC > 0.80), except for the TP (0.74) and MTT (0.30) parameters. The CCC between readers was found to be excellent (CCC > 0.80) for all parameters except for TP (0.71) and MTT (0.52). There was a large Coefficient of Variation (COV) in intra-tumor measurements for 2D parameters (0.18-0.52). Same-tumor measurements made in 3D were significantly different (P = 0.001) than measurements made in 2D; a percent difference of up to 86% was observed between measurements made in 2D compared to 3D in the same tumor. Conclusions: 3D DCE-US imaging of liver metastases with a matrix array transducer is feasible and repeatable in the clinic. Results support 3D instead of 2D DCE US imaging to minimize sampling errors due to tumor heterogeneity. Ivyspring International Publisher 2017-08-23 /pmc/articles/PMC5667345/ /pubmed/29109773 http://dx.doi.org/10.7150/thno.20329 Text en © Ivyspring International Publisher This is an open access article distributed under the terms of the Creative Commons Attribution (CC BY-NC) license (https://creativecommons.org/licenses/by-nc/4.0/). See http://ivyspring.com/terms for full terms and conditions.
spellingShingle Research Paper
El Kaffas, Ahmed
Sigrist, Rosa Maria Silveira
Fisher, George
Bachawal, Sunitha
Liau, Joy
Wang, Huaijun
Karanany, Alexander
Durot, Isabelle
Rosenberg, Jarrett
Hristov, Dimitre
Willmann, Jürgen K.
Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title_full Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title_fullStr Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title_full_unstemmed Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title_short Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
title_sort quantitative three-dimensional dynamic contrast-enhanced ultrasound imaging: first-in-human pilot study in patients with liver metastases
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667345/
https://www.ncbi.nlm.nih.gov/pubmed/29109773
http://dx.doi.org/10.7150/thno.20329
work_keys_str_mv AT elkaffasahmed quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT sigristrosamariasilveira quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT fishergeorge quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT bachawalsunitha quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT liaujoy quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT wanghuaijun quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT karananyalexander quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT durotisabelle quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT rosenbergjarrett quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT hristovdimitre quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases
AT willmannjurgenk quantitativethreedimensionaldynamiccontrastenhancedultrasoundimagingfirstinhumanpilotstudyinpatientswithlivermetastases