Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices

BACKGROUND: Continuous flow left ventricular assist device (CF-LVAD) patients have a high prevalence of gastrointestinal bleeding from the small bowel. Video capsule endoscopy (VCE) is often used for diagnosis in these patients, but efficacy has yet to be determined. In this study, we evaluated the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zikos, Thomas A., Pan, Jennifer, Limketkai, Berkeley, Banerjee, Dipanjan, Fernandez-Becker, Nielsen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667693/
https://www.ncbi.nlm.nih.gov/pubmed/29118868
http://dx.doi.org/10.14740/gr908w
_version_ 1783275529620684800
author Zikos, Thomas A.
Pan, Jennifer
Limketkai, Berkeley
Banerjee, Dipanjan
Fernandez-Becker, Nielsen
author_facet Zikos, Thomas A.
Pan, Jennifer
Limketkai, Berkeley
Banerjee, Dipanjan
Fernandez-Becker, Nielsen
author_sort Zikos, Thomas A.
collection PubMed
description BACKGROUND: Continuous flow left ventricular assist device (CF-LVAD) patients have a high prevalence of gastrointestinal bleeding from the small bowel. Video capsule endoscopy (VCE) is often used for diagnosis in these patients, but efficacy has yet to be determined. In this study, we evaluated the efficacy of VCE in the management of CF-LVAD patients with suspected small bowel bleeding by comparing to a non-VCE CF-LVAD control group. METHODS: We retrospectively reviewed the charts of all patients with CF-LVADs implanted at Stanford Hospital from January 2010 to October 2015. Patients were included in the study if there was a clinical suspicion of small bowel bleeding and either a negative upper endoscopy or colonoscopy. RESULTS: A total of 26 patients met inclusion criteria for a total of 15 encounters where VCE was done, and 25 where VCE was not done. There were no statistical differences when comparing these groups in terms of medical therapy use (thalidomide or octreotide), enteroscopy use (double-balloon or push), intervention on lesions, or any 30-day outcomes. There was no advantage to VCE with regard to the composite endpoint time to re-bleed or death related to re-bleeding (median 114 vs. 161 days, P = 0.15) after removing patients who did not get a VCE due to death or critical illness. CONCLUSIONS: We did not find VCE changed management or outcomes in CF-LVAD patients with suspected small bowel bleeding at our institution when compared to a non-VCE control group. Our experience is small and single center, and larger, multi-center studies could further elucidate the utility of VCE in this patient population.
format Online
Article
Text
id pubmed-5667693
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-56676932017-11-08 Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices Zikos, Thomas A. Pan, Jennifer Limketkai, Berkeley Banerjee, Dipanjan Fernandez-Becker, Nielsen Gastroenterology Res Original Article BACKGROUND: Continuous flow left ventricular assist device (CF-LVAD) patients have a high prevalence of gastrointestinal bleeding from the small bowel. Video capsule endoscopy (VCE) is often used for diagnosis in these patients, but efficacy has yet to be determined. In this study, we evaluated the efficacy of VCE in the management of CF-LVAD patients with suspected small bowel bleeding by comparing to a non-VCE CF-LVAD control group. METHODS: We retrospectively reviewed the charts of all patients with CF-LVADs implanted at Stanford Hospital from January 2010 to October 2015. Patients were included in the study if there was a clinical suspicion of small bowel bleeding and either a negative upper endoscopy or colonoscopy. RESULTS: A total of 26 patients met inclusion criteria for a total of 15 encounters where VCE was done, and 25 where VCE was not done. There were no statistical differences when comparing these groups in terms of medical therapy use (thalidomide or octreotide), enteroscopy use (double-balloon or push), intervention on lesions, or any 30-day outcomes. There was no advantage to VCE with regard to the composite endpoint time to re-bleed or death related to re-bleeding (median 114 vs. 161 days, P = 0.15) after removing patients who did not get a VCE due to death or critical illness. CONCLUSIONS: We did not find VCE changed management or outcomes in CF-LVAD patients with suspected small bowel bleeding at our institution when compared to a non-VCE control group. Our experience is small and single center, and larger, multi-center studies could further elucidate the utility of VCE in this patient population. Elmer Press 2017-10 2017-10-26 /pmc/articles/PMC5667693/ /pubmed/29118868 http://dx.doi.org/10.14740/gr908w Text en Copyright 2017, Zikos et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zikos, Thomas A.
Pan, Jennifer
Limketkai, Berkeley
Banerjee, Dipanjan
Fernandez-Becker, Nielsen
Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title_full Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title_fullStr Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title_full_unstemmed Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title_short Efficacy of Video Capsule Endoscopy in the Management of Suspected Small Bowel Bleeding in Patients With Continuous Flow Left Ventricular Assist Devices
title_sort efficacy of video capsule endoscopy in the management of suspected small bowel bleeding in patients with continuous flow left ventricular assist devices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667693/
https://www.ncbi.nlm.nih.gov/pubmed/29118868
http://dx.doi.org/10.14740/gr908w
work_keys_str_mv AT zikosthomasa efficacyofvideocapsuleendoscopyinthemanagementofsuspectedsmallbowelbleedinginpatientswithcontinuousflowleftventricularassistdevices
AT panjennifer efficacyofvideocapsuleendoscopyinthemanagementofsuspectedsmallbowelbleedinginpatientswithcontinuousflowleftventricularassistdevices
AT limketkaiberkeley efficacyofvideocapsuleendoscopyinthemanagementofsuspectedsmallbowelbleedinginpatientswithcontinuousflowleftventricularassistdevices
AT banerjeedipanjan efficacyofvideocapsuleendoscopyinthemanagementofsuspectedsmallbowelbleedinginpatientswithcontinuousflowleftventricularassistdevices
AT fernandezbeckernielsen efficacyofvideocapsuleendoscopyinthemanagementofsuspectedsmallbowelbleedinginpatientswithcontinuousflowleftventricularassistdevices