Cargando…

A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure

Staphylococcus warneri, a coagulase negative staphylococcus, has been isolated in prosthetic device-related infections and has been reported as a rare cause of endocarditis. We report a case of prosthetic aortic valve S. warneri endocarditis, in which the patient lacked typical infectious signs and...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuvhenguhwa, Maita S., Belgrave, Kevin O., Shah, Sonia U., Bayer, Arnold S., Miller, Loren G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elmer Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667712/
https://www.ncbi.nlm.nih.gov/pubmed/29118887
http://dx.doi.org/10.14740/cr588w
_version_ 1783275536699621376
author Kuvhenguhwa, Maita S.
Belgrave, Kevin O.
Shah, Sonia U.
Bayer, Arnold S.
Miller, Loren G.
author_facet Kuvhenguhwa, Maita S.
Belgrave, Kevin O.
Shah, Sonia U.
Bayer, Arnold S.
Miller, Loren G.
author_sort Kuvhenguhwa, Maita S.
collection PubMed
description Staphylococcus warneri, a coagulase negative staphylococcus, has been isolated in prosthetic device-related infections and has been reported as a rare cause of endocarditis. We report a case of prosthetic aortic valve S. warneri endocarditis, in which the patient lacked typical infectious signs and symptoms, instead presenting with congestive heart failure due to perforation of the valve. Providers should consider endocarditis with a low virulence pathogen such as S. warneri when a patient with a prosthetic valve presents with heart failure, even in the absence of fever, leukocytosis and other infectious symptoms.
format Online
Article
Text
id pubmed-5667712
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elmer Press
record_format MEDLINE/PubMed
spelling pubmed-56677122017-11-08 A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure Kuvhenguhwa, Maita S. Belgrave, Kevin O. Shah, Sonia U. Bayer, Arnold S. Miller, Loren G. Cardiol Res Case Report Staphylococcus warneri, a coagulase negative staphylococcus, has been isolated in prosthetic device-related infections and has been reported as a rare cause of endocarditis. We report a case of prosthetic aortic valve S. warneri endocarditis, in which the patient lacked typical infectious signs and symptoms, instead presenting with congestive heart failure due to perforation of the valve. Providers should consider endocarditis with a low virulence pathogen such as S. warneri when a patient with a prosthetic valve presents with heart failure, even in the absence of fever, leukocytosis and other infectious symptoms. Elmer Press 2017-10 2017-10-27 /pmc/articles/PMC5667712/ /pubmed/29118887 http://dx.doi.org/10.14740/cr588w Text en Copyright 2017, Kuvhenguhwa et al. http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Kuvhenguhwa, Maita S.
Belgrave, Kevin O.
Shah, Sonia U.
Bayer, Arnold S.
Miller, Loren G.
A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title_full A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title_fullStr A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title_full_unstemmed A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title_short A Case of Early Prosthetic Valve Endocarditis Caused by Staphylococcus warneri in a Patient Presenting With Congestive Heart Failure
title_sort case of early prosthetic valve endocarditis caused by staphylococcus warneri in a patient presenting with congestive heart failure
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667712/
https://www.ncbi.nlm.nih.gov/pubmed/29118887
http://dx.doi.org/10.14740/cr588w
work_keys_str_mv AT kuvhenguhwamaitas acaseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT belgravekevino acaseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT shahsoniau acaseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT bayerarnolds acaseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT millerloreng acaseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT kuvhenguhwamaitas caseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT belgravekevino caseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT shahsoniau caseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT bayerarnolds caseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure
AT millerloreng caseofearlyprostheticvalveendocarditiscausedbystaphylococcuswarneriinapatientpresentingwithcongestiveheartfailure