Cargando…

Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens

PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis...

Descripción completa

Detalles Bibliográficos
Autores principales: de Medeiros, André Lins, de Araújo Rolim, André Gustavo, Motta, Antonio Francisco Pimenta, Ventura, Bruna Vieira, Vilar, César, Chaves, Mário Augusto Pereira Dias, Carricondo, Pedro Carlos, Hida, Wilson Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667791/
https://www.ncbi.nlm.nih.gov/pubmed/29138533
http://dx.doi.org/10.2147/OPTH.S145945
_version_ 1783275552079085568
author de Medeiros, André Lins
de Araújo Rolim, André Gustavo
Motta, Antonio Francisco Pimenta
Ventura, Bruna Vieira
Vilar, César
Chaves, Mário Augusto Pereira Dias
Carricondo, Pedro Carlos
Hida, Wilson Takashi
author_facet de Medeiros, André Lins
de Araújo Rolim, André Gustavo
Motta, Antonio Francisco Pimenta
Ventura, Bruna Vieira
Vilar, César
Chaves, Mário Augusto Pereira Dias
Carricondo, Pedro Carlos
Hida, Wilson Takashi
author_sort de Medeiros, André Lins
collection PubMed
description PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony(®) ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis(®) ZMB00 (group B). METHODS: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. RESULTS: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. CONCLUSION: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm.
format Online
Article
Text
id pubmed-5667791
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-56677912017-11-14 Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens de Medeiros, André Lins de Araújo Rolim, André Gustavo Motta, Antonio Francisco Pimenta Ventura, Bruna Vieira Vilar, César Chaves, Mário Augusto Pereira Dias Carricondo, Pedro Carlos Hida, Wilson Takashi Clin Ophthalmol Original Research PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony(®) ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis(®) ZMB00 (group B). METHODS: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. RESULTS: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. CONCLUSION: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. Dove Medical Press 2017-10-26 /pmc/articles/PMC5667791/ /pubmed/29138533 http://dx.doi.org/10.2147/OPTH.S145945 Text en © 2017 de Medeiros et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
de Medeiros, André Lins
de Araújo Rolim, André Gustavo
Motta, Antonio Francisco Pimenta
Ventura, Bruna Vieira
Vilar, César
Chaves, Mário Augusto Pereira Dias
Carricondo, Pedro Carlos
Hida, Wilson Takashi
Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_full Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_fullStr Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_full_unstemmed Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_short Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
title_sort comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667791/
https://www.ncbi.nlm.nih.gov/pubmed/29138533
http://dx.doi.org/10.2147/OPTH.S145945
work_keys_str_mv AT demedeirosandrelins comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT dearaujorolimandregustavo comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT mottaantoniofranciscopimenta comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT venturabrunavieira comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT vilarcesar comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT chavesmarioaugustopereiradias comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT carricondopedrocarlos comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens
AT hidawilsontakashi comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens