Cargando…
Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667791/ https://www.ncbi.nlm.nih.gov/pubmed/29138533 http://dx.doi.org/10.2147/OPTH.S145945 |
_version_ | 1783275552079085568 |
---|---|
author | de Medeiros, André Lins de Araújo Rolim, André Gustavo Motta, Antonio Francisco Pimenta Ventura, Bruna Vieira Vilar, César Chaves, Mário Augusto Pereira Dias Carricondo, Pedro Carlos Hida, Wilson Takashi |
author_facet | de Medeiros, André Lins de Araújo Rolim, André Gustavo Motta, Antonio Francisco Pimenta Ventura, Bruna Vieira Vilar, César Chaves, Mário Augusto Pereira Dias Carricondo, Pedro Carlos Hida, Wilson Takashi |
author_sort | de Medeiros, André Lins |
collection | PubMed |
description | PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony(®) ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis(®) ZMB00 (group B). METHODS: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. RESULTS: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. CONCLUSION: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. |
format | Online Article Text |
id | pubmed-5667791 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-56677912017-11-14 Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens de Medeiros, André Lins de Araújo Rolim, André Gustavo Motta, Antonio Francisco Pimenta Ventura, Bruna Vieira Vilar, César Chaves, Mário Augusto Pereira Dias Carricondo, Pedro Carlos Hida, Wilson Takashi Clin Ophthalmol Original Research PURPOSE: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ(®) PanOptix(®) TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony(®) ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis(®) ZMB00 (group B). METHODS: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. RESULTS: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. CONCLUSION: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. Dove Medical Press 2017-10-26 /pmc/articles/PMC5667791/ /pubmed/29138533 http://dx.doi.org/10.2147/OPTH.S145945 Text en © 2017 de Medeiros et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research de Medeiros, André Lins de Araújo Rolim, André Gustavo Motta, Antonio Francisco Pimenta Ventura, Bruna Vieira Vilar, César Chaves, Mário Augusto Pereira Dias Carricondo, Pedro Carlos Hida, Wilson Takashi Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title | Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title_full | Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title_fullStr | Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title_full_unstemmed | Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title_short | Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
title_sort | comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5667791/ https://www.ncbi.nlm.nih.gov/pubmed/29138533 http://dx.doi.org/10.2147/OPTH.S145945 |
work_keys_str_mv | AT demedeirosandrelins comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT dearaujorolimandregustavo comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT mottaantoniofranciscopimenta comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT venturabrunavieira comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT vilarcesar comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT chavesmarioaugustopereiradias comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT carricondopedrocarlos comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens AT hidawilsontakashi comparisonofvisualoutcomesafterbilateralimplantationofadiffractivetrifocalintraocularlensandblendedimplantationofanextendeddepthoffocusintraocularlenswithadiffractivebifocalintraocularlens |