IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms
BACKGROUND: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer pr...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668221/ https://www.ncbi.nlm.nih.gov/pubmed/29098485 http://dx.doi.org/10.1186/s13550-017-0339-3 |
_version_ | 1783275625472065536 |
---|---|
author | Andersson, Martin Johansson, Lennart Eckerman, Keith Mattsson, Sören |
author_facet | Andersson, Martin Johansson, Lennart Eckerman, Keith Mattsson, Sören |
author_sort | Andersson, Martin |
collection | PubMed |
description | BACKGROUND: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. RESULTS: The absorbed doses and effective dose of (131)I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered (18)F-FDG and orally administered (99m)Tc-pertechnetate and (131)I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for (18)F-FDG, 0.014 mSv/MBq for (99m)Tc-pertechnetate, and 16 mSv/MBq for (131)I-iodide. CONCLUSIONS: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org. |
format | Online Article Text |
id | pubmed-5668221 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-56682212017-11-16 IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms Andersson, Martin Johansson, Lennart Eckerman, Keith Mattsson, Sören EJNMMI Res Original Research BACKGROUND: To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. RESULTS: The absorbed doses and effective dose of (131)I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered (18)F-FDG and orally administered (99m)Tc-pertechnetate and (131)I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for (18)F-FDG, 0.014 mSv/MBq for (99m)Tc-pertechnetate, and 16 mSv/MBq for (131)I-iodide. CONCLUSIONS: The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org. Springer Berlin Heidelberg 2017-11-03 /pmc/articles/PMC5668221/ /pubmed/29098485 http://dx.doi.org/10.1186/s13550-017-0339-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Andersson, Martin Johansson, Lennart Eckerman, Keith Mattsson, Sören IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title | IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title_full | IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title_fullStr | IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title_full_unstemmed | IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title_short | IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms |
title_sort | idac-dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the icrp adult reference voxel phantoms |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668221/ https://www.ncbi.nlm.nih.gov/pubmed/29098485 http://dx.doi.org/10.1186/s13550-017-0339-3 |
work_keys_str_mv | AT anderssonmartin idacdose21aninternaldosimetryprogramfordiagnosticnuclearmedicinebasedontheicrpadultreferencevoxelphantoms AT johanssonlennart idacdose21aninternaldosimetryprogramfordiagnosticnuclearmedicinebasedontheicrpadultreferencevoxelphantoms AT eckermankeith idacdose21aninternaldosimetryprogramfordiagnosticnuclearmedicinebasedontheicrpadultreferencevoxelphantoms AT mattssonsoren idacdose21aninternaldosimetryprogramfordiagnosticnuclearmedicinebasedontheicrpadultreferencevoxelphantoms |