Cargando…

Clinical evaluation of final impressions from three-dimensional printed custom trays

This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocura...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Yuchun, Chen, Hu, Li, Hong, Deng, Kehui, Zhao, Tian, Wang, Yong, Zhou, Yongsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668249/
https://www.ncbi.nlm.nih.gov/pubmed/29097699
http://dx.doi.org/10.1038/s41598-017-14005-8
_version_ 1783275632135766016
author Sun, Yuchun
Chen, Hu
Li, Hong
Deng, Kehui
Zhao, Tian
Wang, Yong
Zhou, Yongsheng
author_facet Sun, Yuchun
Chen, Hu
Li, Hong
Deng, Kehui
Zhao, Tian
Wang, Yong
Zhou, Yongsheng
author_sort Sun, Yuchun
collection PubMed
description This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocurable materials were produced as controls. Both 3D printed custom trays and manually made ones were used to take impressions from edentulous patients. After 3D scanning of the final impression, the impression materials were removed, thus the underneath tray surfaces were able to be scanned, allowing the thickness of the impression materials to be measured. Final impressions obtained by pre-border-molded 3D printed trays were scanned as references, to which the flange extension deviations and morphology deviations of the impressions taken by both 3D printed trays and manually made ones were calculated. The results showed that (1) impressions from 3D printed custom trays had better thickness distribution than that of manually made ones; (2) impression morphology deviations in non-marginal area were neither statistic different between 3D printed trays and manually made trays, nor between trays with and without tissue stops; and (3) final impressions taken by custom trays without pre-border-molding were tended to have insufficient flange extensions.
format Online
Article
Text
id pubmed-5668249
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-56682492017-11-08 Clinical evaluation of final impressions from three-dimensional printed custom trays Sun, Yuchun Chen, Hu Li, Hong Deng, Kehui Zhao, Tian Wang, Yong Zhou, Yongsheng Sci Rep Article This study aimed to evaluate the quality of the final impressions taken by three-dimensional printed custom trays for edentulous patients. Custom trays were designed with or without saddle-shaped tissue stops and fabricated by three-dimensional printing techniques. Manually made trays with photocurable materials were produced as controls. Both 3D printed custom trays and manually made ones were used to take impressions from edentulous patients. After 3D scanning of the final impression, the impression materials were removed, thus the underneath tray surfaces were able to be scanned, allowing the thickness of the impression materials to be measured. Final impressions obtained by pre-border-molded 3D printed trays were scanned as references, to which the flange extension deviations and morphology deviations of the impressions taken by both 3D printed trays and manually made ones were calculated. The results showed that (1) impressions from 3D printed custom trays had better thickness distribution than that of manually made ones; (2) impression morphology deviations in non-marginal area were neither statistic different between 3D printed trays and manually made trays, nor between trays with and without tissue stops; and (3) final impressions taken by custom trays without pre-border-molding were tended to have insufficient flange extensions. Nature Publishing Group UK 2017-11-02 /pmc/articles/PMC5668249/ /pubmed/29097699 http://dx.doi.org/10.1038/s41598-017-14005-8 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Sun, Yuchun
Chen, Hu
Li, Hong
Deng, Kehui
Zhao, Tian
Wang, Yong
Zhou, Yongsheng
Clinical evaluation of final impressions from three-dimensional printed custom trays
title Clinical evaluation of final impressions from three-dimensional printed custom trays
title_full Clinical evaluation of final impressions from three-dimensional printed custom trays
title_fullStr Clinical evaluation of final impressions from three-dimensional printed custom trays
title_full_unstemmed Clinical evaluation of final impressions from three-dimensional printed custom trays
title_short Clinical evaluation of final impressions from three-dimensional printed custom trays
title_sort clinical evaluation of final impressions from three-dimensional printed custom trays
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668249/
https://www.ncbi.nlm.nih.gov/pubmed/29097699
http://dx.doi.org/10.1038/s41598-017-14005-8
work_keys_str_mv AT sunyuchun clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT chenhu clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT lihong clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT dengkehui clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT zhaotian clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT wangyong clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays
AT zhouyongsheng clinicalevaluationoffinalimpressionsfromthreedimensionalprintedcustomtrays