Cargando…

In vivo measurement of regional corneal tangent modulus

Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corne...

Descripción completa

Detalles Bibliográficos
Autores principales: Hon, Ying, Chen, Guo-Zhen, Lu, Shu-Hao, Lam, David CC, Lam, Andrew KC
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668273/
https://www.ncbi.nlm.nih.gov/pubmed/29097675
http://dx.doi.org/10.1038/s41598-017-14750-w
_version_ 1783275637657567232
author Hon, Ying
Chen, Guo-Zhen
Lu, Shu-Hao
Lam, David CC
Lam, Andrew KC
author_facet Hon, Ying
Chen, Guo-Zhen
Lu, Shu-Hao
Lam, David CC
Lam, Andrew KC
author_sort Hon, Ying
collection PubMed
description Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corneal tangent modulus (E) of 25 healthy subjects was calculated from these data. After confirming normality, repeated measures analysis of variance (RMANOVA) revealed significant difference in S (F(2, 48) = 21.36, p < 0.001) at different corneal regions and direction of fixations. E also varied significantly at different corneal regions and direction of fixations (RMANOVA: F(2, 48) = 23.06, p < 0.001). A higher S and a lower E were observed at the temporal region compared with the corneal centre. Nasal fixation further increased S and E values compared with primary fixation. Due to the specific arrangement of corneal collagen fibrils, heterogeneity of corneal biomechanical properties is expected. In future clinical practice, localized corneal biomechanical alternation and measurement might assist corneal disease detection and post-surgery management. In addition, practitioners should be aware of the fixation effect on corneal biomechanical measurement.
format Online
Article
Text
id pubmed-5668273
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-56682732017-11-08 In vivo measurement of regional corneal tangent modulus Hon, Ying Chen, Guo-Zhen Lu, Shu-Hao Lam, David CC Lam, Andrew KC Sci Rep Article Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corneal tangent modulus (E) of 25 healthy subjects was calculated from these data. After confirming normality, repeated measures analysis of variance (RMANOVA) revealed significant difference in S (F(2, 48) = 21.36, p < 0.001) at different corneal regions and direction of fixations. E also varied significantly at different corneal regions and direction of fixations (RMANOVA: F(2, 48) = 23.06, p < 0.001). A higher S and a lower E were observed at the temporal region compared with the corneal centre. Nasal fixation further increased S and E values compared with primary fixation. Due to the specific arrangement of corneal collagen fibrils, heterogeneity of corneal biomechanical properties is expected. In future clinical practice, localized corneal biomechanical alternation and measurement might assist corneal disease detection and post-surgery management. In addition, practitioners should be aware of the fixation effect on corneal biomechanical measurement. Nature Publishing Group UK 2017-11-02 /pmc/articles/PMC5668273/ /pubmed/29097675 http://dx.doi.org/10.1038/s41598-017-14750-w Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Hon, Ying
Chen, Guo-Zhen
Lu, Shu-Hao
Lam, David CC
Lam, Andrew KC
In vivo measurement of regional corneal tangent modulus
title In vivo measurement of regional corneal tangent modulus
title_full In vivo measurement of regional corneal tangent modulus
title_fullStr In vivo measurement of regional corneal tangent modulus
title_full_unstemmed In vivo measurement of regional corneal tangent modulus
title_short In vivo measurement of regional corneal tangent modulus
title_sort in vivo measurement of regional corneal tangent modulus
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668273/
https://www.ncbi.nlm.nih.gov/pubmed/29097675
http://dx.doi.org/10.1038/s41598-017-14750-w
work_keys_str_mv AT honying invivomeasurementofregionalcornealtangentmodulus
AT chenguozhen invivomeasurementofregionalcornealtangentmodulus
AT lushuhao invivomeasurementofregionalcornealtangentmodulus
AT lamdavidcc invivomeasurementofregionalcornealtangentmodulus
AT lamandrewkc invivomeasurementofregionalcornealtangentmodulus