In vivo measurement of regional corneal tangent modulus
Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corne...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668273/ https://www.ncbi.nlm.nih.gov/pubmed/29097675 http://dx.doi.org/10.1038/s41598-017-14750-w |
_version_ | 1783275637657567232 |
---|---|
author | Hon, Ying Chen, Guo-Zhen Lu, Shu-Hao Lam, David CC Lam, Andrew KC |
author_facet | Hon, Ying Chen, Guo-Zhen Lu, Shu-Hao Lam, David CC Lam, Andrew KC |
author_sort | Hon, Ying |
collection | PubMed |
description | Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corneal tangent modulus (E) of 25 healthy subjects was calculated from these data. After confirming normality, repeated measures analysis of variance (RMANOVA) revealed significant difference in S (F(2, 48) = 21.36, p < 0.001) at different corneal regions and direction of fixations. E also varied significantly at different corneal regions and direction of fixations (RMANOVA: F(2, 48) = 23.06, p < 0.001). A higher S and a lower E were observed at the temporal region compared with the corneal centre. Nasal fixation further increased S and E values compared with primary fixation. Due to the specific arrangement of corneal collagen fibrils, heterogeneity of corneal biomechanical properties is expected. In future clinical practice, localized corneal biomechanical alternation and measurement might assist corneal disease detection and post-surgery management. In addition, practitioners should be aware of the fixation effect on corneal biomechanical measurement. |
format | Online Article Text |
id | pubmed-5668273 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-56682732017-11-08 In vivo measurement of regional corneal tangent modulus Hon, Ying Chen, Guo-Zhen Lu, Shu-Hao Lam, David CC Lam, Andrew KC Sci Rep Article Currently available clinical devices are unable to measure corneal biomechanics other than at the central region. Corneal stiffness (S), thickness, and radius of curvature was measured at the central cornea (primary fixation) and 3 mm from the temporal limbus (primary and nasal fixations). The corneal tangent modulus (E) of 25 healthy subjects was calculated from these data. After confirming normality, repeated measures analysis of variance (RMANOVA) revealed significant difference in S (F(2, 48) = 21.36, p < 0.001) at different corneal regions and direction of fixations. E also varied significantly at different corneal regions and direction of fixations (RMANOVA: F(2, 48) = 23.06, p < 0.001). A higher S and a lower E were observed at the temporal region compared with the corneal centre. Nasal fixation further increased S and E values compared with primary fixation. Due to the specific arrangement of corneal collagen fibrils, heterogeneity of corneal biomechanical properties is expected. In future clinical practice, localized corneal biomechanical alternation and measurement might assist corneal disease detection and post-surgery management. In addition, practitioners should be aware of the fixation effect on corneal biomechanical measurement. Nature Publishing Group UK 2017-11-02 /pmc/articles/PMC5668273/ /pubmed/29097675 http://dx.doi.org/10.1038/s41598-017-14750-w Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Hon, Ying Chen, Guo-Zhen Lu, Shu-Hao Lam, David CC Lam, Andrew KC In vivo measurement of regional corneal tangent modulus |
title | In vivo measurement of regional corneal tangent modulus |
title_full | In vivo measurement of regional corneal tangent modulus |
title_fullStr | In vivo measurement of regional corneal tangent modulus |
title_full_unstemmed | In vivo measurement of regional corneal tangent modulus |
title_short | In vivo measurement of regional corneal tangent modulus |
title_sort | in vivo measurement of regional corneal tangent modulus |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668273/ https://www.ncbi.nlm.nih.gov/pubmed/29097675 http://dx.doi.org/10.1038/s41598-017-14750-w |
work_keys_str_mv | AT honying invivomeasurementofregionalcornealtangentmodulus AT chenguozhen invivomeasurementofregionalcornealtangentmodulus AT lushuhao invivomeasurementofregionalcornealtangentmodulus AT lamdavidcc invivomeasurementofregionalcornealtangentmodulus AT lamandrewkc invivomeasurementofregionalcornealtangentmodulus |