Cargando…
Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonator...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668368/ https://www.ncbi.nlm.nih.gov/pubmed/29151677 http://dx.doi.org/10.1007/s00723-017-0955-0 |
_version_ | 1783275659935612928 |
---|---|
author | Sidabras, Jason W. Reijerse, Edward J. Lubitz, Wolfgang |
author_facet | Sidabras, Jason W. Reijerse, Edward J. Lubitz, Wolfgang |
author_sort | Sidabras, Jason W. |
collection | PubMed |
description | Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonators is introduced: the uniform field re-entrant cylindrical TE[Formula: see text] cavity. Here, a UF cylindrical TE[Formula: see text] cavity is designed with re-entrant fins to increase the overall resonator efficiency to match the resonator efficiency maximum of a typical cylindrical TE[Formula: see text] cavity. The new UF re-entrant cylindrical TE[Formula: see text] cavity is designed for Q-band (34 GHz) and is calculated to have the same electron paramagnetic resonance (EPR) signal intensity as a TE[Formula: see text] cavity, a 60% increase in average resonator efficiency [Formula: see text] over the sample, and has a [Formula: see text] profile that is 79.8% uniform over the entire sample volume (98% uniform over the region-of-interest). A new H-type T-junction waveguide coupler with inductive obstacles is introduced that increases the dynamic range of a movable short coupler while reducing the frequency shift by 43% during over-coupling. The resonator assembly is fabricated and tested both on the bench and with EPR experiments. This resonator provides a template to improve EPR spectroscopy for pulse experiments at high frequencies. |
format | Online Article Text |
id | pubmed-5668368 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-56683682017-11-16 Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band Sidabras, Jason W. Reijerse, Edward J. Lubitz, Wolfgang Appl Magn Reson Original Paper Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonators is introduced: the uniform field re-entrant cylindrical TE[Formula: see text] cavity. Here, a UF cylindrical TE[Formula: see text] cavity is designed with re-entrant fins to increase the overall resonator efficiency to match the resonator efficiency maximum of a typical cylindrical TE[Formula: see text] cavity. The new UF re-entrant cylindrical TE[Formula: see text] cavity is designed for Q-band (34 GHz) and is calculated to have the same electron paramagnetic resonance (EPR) signal intensity as a TE[Formula: see text] cavity, a 60% increase in average resonator efficiency [Formula: see text] over the sample, and has a [Formula: see text] profile that is 79.8% uniform over the entire sample volume (98% uniform over the region-of-interest). A new H-type T-junction waveguide coupler with inductive obstacles is introduced that increases the dynamic range of a movable short coupler while reducing the frequency shift by 43% during over-coupling. The resonator assembly is fabricated and tested both on the bench and with EPR experiments. This resonator provides a template to improve EPR spectroscopy for pulse experiments at high frequencies. Springer Vienna 2017-09-30 2017 /pmc/articles/PMC5668368/ /pubmed/29151677 http://dx.doi.org/10.1007/s00723-017-0955-0 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Paper Sidabras, Jason W. Reijerse, Edward J. Lubitz, Wolfgang Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title | Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title_full | Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title_fullStr | Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title_full_unstemmed | Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title_short | Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band |
title_sort | uniform field re-entrant cylindrical te[formula: see text] cavity for pulse electron paramagnetic resonance spectroscopy at q-band |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668368/ https://www.ncbi.nlm.nih.gov/pubmed/29151677 http://dx.doi.org/10.1007/s00723-017-0955-0 |
work_keys_str_mv | AT sidabrasjasonw uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband AT reijerseedwardj uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband AT lubitzwolfgang uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband |