Cargando…

Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band

Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonator...

Descripción completa

Detalles Bibliográficos
Autores principales: Sidabras, Jason W., Reijerse, Edward J., Lubitz, Wolfgang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668368/
https://www.ncbi.nlm.nih.gov/pubmed/29151677
http://dx.doi.org/10.1007/s00723-017-0955-0
_version_ 1783275659935612928
author Sidabras, Jason W.
Reijerse, Edward J.
Lubitz, Wolfgang
author_facet Sidabras, Jason W.
Reijerse, Edward J.
Lubitz, Wolfgang
author_sort Sidabras, Jason W.
collection PubMed
description Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonators is introduced: the uniform field re-entrant cylindrical TE[Formula: see text] cavity. Here, a UF cylindrical TE[Formula: see text] cavity is designed with re-entrant fins to increase the overall resonator efficiency to match the resonator efficiency maximum of a typical cylindrical TE[Formula: see text] cavity. The new UF re-entrant cylindrical TE[Formula: see text] cavity is designed for Q-band (34 GHz) and is calculated to have the same electron paramagnetic resonance (EPR) signal intensity as a TE[Formula: see text] cavity, a 60% increase in average resonator efficiency [Formula: see text] over the sample, and has a [Formula: see text] profile that is 79.8% uniform over the entire sample volume (98% uniform over the region-of-interest). A new H-type T-junction waveguide coupler with inductive obstacles is introduced that increases the dynamic range of a movable short coupler while reducing the frequency shift by 43% during over-coupling. The resonator assembly is fabricated and tested both on the bench and with EPR experiments. This resonator provides a template to improve EPR spectroscopy for pulse experiments at high frequencies.
format Online
Article
Text
id pubmed-5668368
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-56683682017-11-16 Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band Sidabras, Jason W. Reijerse, Edward J. Lubitz, Wolfgang Appl Magn Reson Original Paper Uniform field (UF) resonators create a region-of-interest, where the sample volume receives a homogeneous microwave magnetic field ([Formula: see text] ) excitation. However, as the region-of-interest is increased, resonator efficiency is reduced. In this work, a new class of uniform field resonators is introduced: the uniform field re-entrant cylindrical TE[Formula: see text] cavity. Here, a UF cylindrical TE[Formula: see text] cavity is designed with re-entrant fins to increase the overall resonator efficiency to match the resonator efficiency maximum of a typical cylindrical TE[Formula: see text] cavity. The new UF re-entrant cylindrical TE[Formula: see text] cavity is designed for Q-band (34 GHz) and is calculated to have the same electron paramagnetic resonance (EPR) signal intensity as a TE[Formula: see text] cavity, a 60% increase in average resonator efficiency [Formula: see text] over the sample, and has a [Formula: see text] profile that is 79.8% uniform over the entire sample volume (98% uniform over the region-of-interest). A new H-type T-junction waveguide coupler with inductive obstacles is introduced that increases the dynamic range of a movable short coupler while reducing the frequency shift by 43% during over-coupling. The resonator assembly is fabricated and tested both on the bench and with EPR experiments. This resonator provides a template to improve EPR spectroscopy for pulse experiments at high frequencies. Springer Vienna 2017-09-30 2017 /pmc/articles/PMC5668368/ /pubmed/29151677 http://dx.doi.org/10.1007/s00723-017-0955-0 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Paper
Sidabras, Jason W.
Reijerse, Edward J.
Lubitz, Wolfgang
Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title_full Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title_fullStr Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title_full_unstemmed Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title_short Uniform Field Re-entrant Cylindrical TE[Formula: see text] Cavity for Pulse Electron Paramagnetic Resonance Spectroscopy at Q-band
title_sort uniform field re-entrant cylindrical te[formula: see text] cavity for pulse electron paramagnetic resonance spectroscopy at q-band
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5668368/
https://www.ncbi.nlm.nih.gov/pubmed/29151677
http://dx.doi.org/10.1007/s00723-017-0955-0
work_keys_str_mv AT sidabrasjasonw uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband
AT reijerseedwardj uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband
AT lubitzwolfgang uniformfieldreentrantcylindricalteformulaseetextcavityforpulseelectronparamagneticresonancespectroscopyatqband