Cargando…

Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation

BACKGROUND/AIMS: To identify the usefulness of endoscopic ultrasonography with a mini-probe (EUM) and to create a predictive model for esophageal variceal (EV) recurrence and bleeding following esophageal variceal ligation (EVL). METHODS: A total of 144 patients who received EUM prior to prophylacti...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Soung Won, Kim, Hye Soo, Kim, Sang Gyune, Yoo, Jeong-Ju, Jang, Jae Young, Lee, Sae Hwan, Kim, Hong Soo, Lee, Ji Sung, Kim, Young Seok, Kim, Boo Sung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial Office of Gut and Liver 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5669601/
https://www.ncbi.nlm.nih.gov/pubmed/28651302
http://dx.doi.org/10.5009/gnl16458
_version_ 1783275869940219904
author Jeong, Soung Won
Kim, Hye Soo
Kim, Sang Gyune
Yoo, Jeong-Ju
Jang, Jae Young
Lee, Sae Hwan
Kim, Hong Soo
Lee, Ji Sung
Kim, Young Seok
Kim, Boo Sung
author_facet Jeong, Soung Won
Kim, Hye Soo
Kim, Sang Gyune
Yoo, Jeong-Ju
Jang, Jae Young
Lee, Sae Hwan
Kim, Hong Soo
Lee, Ji Sung
Kim, Young Seok
Kim, Boo Sung
author_sort Jeong, Soung Won
collection PubMed
description BACKGROUND/AIMS: To identify the usefulness of endoscopic ultrasonography with a mini-probe (EUM) and to create a predictive model for esophageal variceal (EV) recurrence and bleeding following esophageal variceal ligation (EVL). METHODS: A total of 144 patients who received EUM prior to prophylactic EVL and met the inclusion criteria were enrolled. EUM findings, EV diameter, paraesophageal vein diameter, and the number of perforating veins were assessed. RESULTS: EV recurrence was observed in 42 patients (29.2%), 10 of whom experienced EV bleeding. Larger diameter of the paraesophageal vein (odds ratio [OR], 1.51; 95% confidence interval [CI], 1.17 to 1.96; p=0.002) and perforating vein (OR, 3.27; 95% CI, 1.11 to 9.65; p=0.032) were significant predictive factors for EV recurrence. However, the diameter of the paraesophageal vein was the only significant risk factor for EV bleeding (adjusted OR, 1.51; 95% CI, 1.06 to 2.16; p=0.022). The areas under the curves of the predictive model for EV recurrence and bleeding were 0.872 (95% CI, 0.811 to 0.934) and 0.811 (95% CI, 0.630 to 0.992), respectively. CONCLUSIONS: The diameter of the paraesophageal vein was a significant predictive factor for EV recurrence and bleeding. The predictive model constructed based on the significant EUM findings exhibited good performance.
format Online
Article
Text
id pubmed-5669601
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Editorial Office of Gut and Liver
record_format MEDLINE/PubMed
spelling pubmed-56696012017-11-07 Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation Jeong, Soung Won Kim, Hye Soo Kim, Sang Gyune Yoo, Jeong-Ju Jang, Jae Young Lee, Sae Hwan Kim, Hong Soo Lee, Ji Sung Kim, Young Seok Kim, Boo Sung Gut Liver Original Article BACKGROUND/AIMS: To identify the usefulness of endoscopic ultrasonography with a mini-probe (EUM) and to create a predictive model for esophageal variceal (EV) recurrence and bleeding following esophageal variceal ligation (EVL). METHODS: A total of 144 patients who received EUM prior to prophylactic EVL and met the inclusion criteria were enrolled. EUM findings, EV diameter, paraesophageal vein diameter, and the number of perforating veins were assessed. RESULTS: EV recurrence was observed in 42 patients (29.2%), 10 of whom experienced EV bleeding. Larger diameter of the paraesophageal vein (odds ratio [OR], 1.51; 95% confidence interval [CI], 1.17 to 1.96; p=0.002) and perforating vein (OR, 3.27; 95% CI, 1.11 to 9.65; p=0.032) were significant predictive factors for EV recurrence. However, the diameter of the paraesophageal vein was the only significant risk factor for EV bleeding (adjusted OR, 1.51; 95% CI, 1.06 to 2.16; p=0.022). The areas under the curves of the predictive model for EV recurrence and bleeding were 0.872 (95% CI, 0.811 to 0.934) and 0.811 (95% CI, 0.630 to 0.992), respectively. CONCLUSIONS: The diameter of the paraesophageal vein was a significant predictive factor for EV recurrence and bleeding. The predictive model constructed based on the significant EUM findings exhibited good performance. Editorial Office of Gut and Liver 2017-11 2017-06-27 /pmc/articles/PMC5669601/ /pubmed/28651302 http://dx.doi.org/10.5009/gnl16458 Text en Copyright © 2017 by The Korean Society of Gastroenterology, the Korean Society of Gastrointestinal Endoscopy, the Korean Society of Neurogastroenterology and Motility, Korean College of Helicobacter and Upper Gastrointestinal Research, Korean Association the Study of Intestinal Diseases, the Korean Association for the Study of the Liver, Korean Pancreatobiliary Association, and Korean Society of Gastrointestinal Cancer. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Soung Won
Kim, Hye Soo
Kim, Sang Gyune
Yoo, Jeong-Ju
Jang, Jae Young
Lee, Sae Hwan
Kim, Hong Soo
Lee, Ji Sung
Kim, Young Seok
Kim, Boo Sung
Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title_full Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title_fullStr Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title_full_unstemmed Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title_short Useful Endoscopic Ultrasonography Parameters and a Predictive Model for the Recurrence of Esophageal Varices and Bleeding after Variceal Ligation
title_sort useful endoscopic ultrasonography parameters and a predictive model for the recurrence of esophageal varices and bleeding after variceal ligation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5669601/
https://www.ncbi.nlm.nih.gov/pubmed/28651302
http://dx.doi.org/10.5009/gnl16458
work_keys_str_mv AT jeongsoungwon usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT kimhyesoo usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT kimsanggyune usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT yoojeongju usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT jangjaeyoung usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT leesaehwan usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT kimhongsoo usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT leejisung usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT kimyoungseok usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation
AT kimboosung usefulendoscopicultrasonographyparametersandapredictivemodelfortherecurrenceofesophagealvaricesandbleedingaftervaricealligation