Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO)
INTRODUCTION: Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications. CASE DESCRIPTION: We report on a 10-month-old infant, body weight of 6.4 kg, with a larg...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5670092/ https://www.ncbi.nlm.nih.gov/pubmed/29101573 http://dx.doi.org/10.1186/s40348-017-0077-7 |
_version_ | 1783275947054596096 |
---|---|
author | Scheidmann, Roman Paul, Thomas Sigler, Matthias |
author_facet | Scheidmann, Roman Paul, Thomas Sigler, Matthias |
author_sort | Scheidmann, Roman |
collection | PubMed |
description | INTRODUCTION: Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications. CASE DESCRIPTION: We report on a 10-month-old infant, body weight of 6.4 kg, with a large ASD who was referred for failure to thrive and dyspnea on exertion. Echocardiography showed two neighboring ASDs centrally located within an atrial septum with a length of 27 mm resulting in significant left-to-right shunting. During cardiac catheterization, hemodynamic significance of the defect as well as normal pulmonary vascular resistance was demonstrated. Balloon sizing of the central ASD showed a stretched defect diameter of 12 × 11 mm. A 20-mm GORE CARDIOFORM septal occluder (GCSO; Goremedical, W. L. Gore & Associates, Inc., Newark, DE, USA) was implanted without any complications. Initial trivial residual shunting resolved during 4 months of follow-up. Right ventricular dimensions declined significantly, and the boy gained body weight properly. DISCUSSION, EVALUATION AND CONCLUSION: As demonstrated in our report, even large ASDs can be closed safely by catheter intervention in small infants. Selection of implant device and optimal sizing is of paramount importance. The size of the delivery sheath (11 French in our patient) is a potential limitation for the GCSO in smaller infants. |
format | Online Article Text |
id | pubmed-5670092 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-56700922017-11-20 Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) Scheidmann, Roman Paul, Thomas Sigler, Matthias Mol Cell Pediatr Case Study INTRODUCTION: Transcatheter closure has become the treatment of choice for secundum atrial septal defects (ASD II), but particularly in small children, there is concern regarding procedure-related complications. CASE DESCRIPTION: We report on a 10-month-old infant, body weight of 6.4 kg, with a large ASD who was referred for failure to thrive and dyspnea on exertion. Echocardiography showed two neighboring ASDs centrally located within an atrial septum with a length of 27 mm resulting in significant left-to-right shunting. During cardiac catheterization, hemodynamic significance of the defect as well as normal pulmonary vascular resistance was demonstrated. Balloon sizing of the central ASD showed a stretched defect diameter of 12 × 11 mm. A 20-mm GORE CARDIOFORM septal occluder (GCSO; Goremedical, W. L. Gore & Associates, Inc., Newark, DE, USA) was implanted without any complications. Initial trivial residual shunting resolved during 4 months of follow-up. Right ventricular dimensions declined significantly, and the boy gained body weight properly. DISCUSSION, EVALUATION AND CONCLUSION: As demonstrated in our report, even large ASDs can be closed safely by catheter intervention in small infants. Selection of implant device and optimal sizing is of paramount importance. The size of the delivery sheath (11 French in our patient) is a potential limitation for the GCSO in smaller infants. Springer Berlin Heidelberg 2017-11-03 /pmc/articles/PMC5670092/ /pubmed/29101573 http://dx.doi.org/10.1186/s40348-017-0077-7 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Case Study Scheidmann, Roman Paul, Thomas Sigler, Matthias Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title | Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title_full | Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title_fullStr | Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title_full_unstemmed | Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title_short | Transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the GORE CARDIOFORM septal occluder (GCSO) |
title_sort | transcatheter atrial septal defect closure in an infant (body weight 6.4 kg) using the gore cardioform septal occluder (gcso) |
topic | Case Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5670092/ https://www.ncbi.nlm.nih.gov/pubmed/29101573 http://dx.doi.org/10.1186/s40348-017-0077-7 |
work_keys_str_mv | AT scheidmannroman transcatheteratrialseptaldefectclosureinaninfantbodyweight64kgusingthegorecardioformseptaloccludergcso AT paulthomas transcatheteratrialseptaldefectclosureinaninfantbodyweight64kgusingthegorecardioformseptaloccludergcso AT siglermatthias transcatheteratrialseptaldefectclosureinaninfantbodyweight64kgusingthegorecardioformseptaloccludergcso |