Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)

Introduction: After early successful experience with transcatheter aortic valve replacement (TAVR), concept of transcatheter implantation of a new valve within a failing bioprosthetic valve emerged. Valve-in-valve (ViV) implantation seems to be a simpler option for high risk surgical patients. Metho...

Descripción completa

Detalles Bibliográficos
Autores principales: Haji Zeinali, Ali Mohammad, Abbasi, Kyomars, Saheb Jam, Mohammad, Yazdani, Shahrooz, Mortazavi, Seyedeh Hamideh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5670337/
https://www.ncbi.nlm.nih.gov/pubmed/29118948
http://dx.doi.org/10.15171/jcvtr.2017.26
_version_ 1783276004093984768
author Haji Zeinali, Ali Mohammad
Abbasi, Kyomars
Saheb Jam, Mohammad
Yazdani, Shahrooz
Mortazavi, Seyedeh Hamideh
author_facet Haji Zeinali, Ali Mohammad
Abbasi, Kyomars
Saheb Jam, Mohammad
Yazdani, Shahrooz
Mortazavi, Seyedeh Hamideh
author_sort Haji Zeinali, Ali Mohammad
collection PubMed
description Introduction: After early successful experience with transcatheter aortic valve replacement (TAVR), concept of transcatheter implantation of a new valve within a failing bioprosthetic valve emerged. Valve-in-valve (ViV) implantation seems to be a simpler option for high risk surgical patients. Methods: We performed five ViV procedures in different valve positions. We included patients with failing bioprosthetic valves with high surgical risk due to concomitant comorbidities. We performed 2 transapical ViV procedures for failing mitral bioprosthetic valves, 1 transfemoral procedure for failing pulmonary valve and 2 transfemoral ViV implantation for failing tricuspid bioprosthetic valves. Results: The procedures were successfully completed in all 5 cases with initial excellent fluoroscopic and echocardiographic verification. There was no valve embolization or paravalvular leakage in any of the cases. Transcatheter valve function was appropriate with echocardiography. Post procedural clinical adverse events like pleural effusion and transient ischemic attack were managed successfully. In midterm follow up all cases remained in appropriate functional class except from the transcatheter pulmonary valve which became moderately stenotic and regurgitant. Conclusion: As the first Iranian all-comers case series with midterm follow up for ViV implantation, we had no mortality. Interestingly none of our patients had neurologic sequelae after the procedure. Midterm follow up for our patients was acceptable with good functional class and appropriate echocardiographic findings. Due to high surgical risk of the redo procedure after failing of a bioprosthetic valve especially in elderly patients with comorbidities, ViV implantation would be a good alternative to surgery for this high risk group.
format Online
Article
Text
id pubmed-5670337
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-56703372017-11-08 Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up) Haji Zeinali, Ali Mohammad Abbasi, Kyomars Saheb Jam, Mohammad Yazdani, Shahrooz Mortazavi, Seyedeh Hamideh J Cardiovasc Thorac Res Original Article Introduction: After early successful experience with transcatheter aortic valve replacement (TAVR), concept of transcatheter implantation of a new valve within a failing bioprosthetic valve emerged. Valve-in-valve (ViV) implantation seems to be a simpler option for high risk surgical patients. Methods: We performed five ViV procedures in different valve positions. We included patients with failing bioprosthetic valves with high surgical risk due to concomitant comorbidities. We performed 2 transapical ViV procedures for failing mitral bioprosthetic valves, 1 transfemoral procedure for failing pulmonary valve and 2 transfemoral ViV implantation for failing tricuspid bioprosthetic valves. Results: The procedures were successfully completed in all 5 cases with initial excellent fluoroscopic and echocardiographic verification. There was no valve embolization or paravalvular leakage in any of the cases. Transcatheter valve function was appropriate with echocardiography. Post procedural clinical adverse events like pleural effusion and transient ischemic attack were managed successfully. In midterm follow up all cases remained in appropriate functional class except from the transcatheter pulmonary valve which became moderately stenotic and regurgitant. Conclusion: As the first Iranian all-comers case series with midterm follow up for ViV implantation, we had no mortality. Interestingly none of our patients had neurologic sequelae after the procedure. Midterm follow up for our patients was acceptable with good functional class and appropriate echocardiographic findings. Due to high surgical risk of the redo procedure after failing of a bioprosthetic valve especially in elderly patients with comorbidities, ViV implantation would be a good alternative to surgery for this high risk group. Tabriz University of Medical Sciences 2017 2017-09-30 /pmc/articles/PMC5670337/ /pubmed/29118948 http://dx.doi.org/10.15171/jcvtr.2017.26 Text en © 2017 The Author(s) This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Haji Zeinali, Ali Mohammad
Abbasi, Kyomars
Saheb Jam, Mohammad
Yazdani, Shahrooz
Mortazavi, Seyedeh Hamideh
Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title_full Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title_fullStr Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title_full_unstemmed Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title_short Transcatheter heart valve in valve implantation with Edwards SAPIEN bioprosthetic valve for different degenerated bioprosthetic valve positions (First Iranian ViV report with mid-term follow up)
title_sort transcatheter heart valve in valve implantation with edwards sapien bioprosthetic valve for different degenerated bioprosthetic valve positions (first iranian viv report with mid-term follow up)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5670337/
https://www.ncbi.nlm.nih.gov/pubmed/29118948
http://dx.doi.org/10.15171/jcvtr.2017.26
work_keys_str_mv AT hajizeinalialimohammad transcatheterheartvalveinvalveimplantationwithedwardssapienbioprostheticvalvefordifferentdegeneratedbioprostheticvalvepositionsfirstiranianvivreportwithmidtermfollowup
AT abbasikyomars transcatheterheartvalveinvalveimplantationwithedwardssapienbioprostheticvalvefordifferentdegeneratedbioprostheticvalvepositionsfirstiranianvivreportwithmidtermfollowup
AT sahebjammohammad transcatheterheartvalveinvalveimplantationwithedwardssapienbioprostheticvalvefordifferentdegeneratedbioprostheticvalvepositionsfirstiranianvivreportwithmidtermfollowup
AT yazdanishahrooz transcatheterheartvalveinvalveimplantationwithedwardssapienbioprostheticvalvefordifferentdegeneratedbioprostheticvalvepositionsfirstiranianvivreportwithmidtermfollowup
AT mortazaviseyedehhamideh transcatheterheartvalveinvalveimplantationwithedwardssapienbioprostheticvalvefordifferentdegeneratedbioprostheticvalvepositionsfirstiranianvivreportwithmidtermfollowup