Cargando…

A Pilot Study of Nebulized Heparin for Prevention of Ventilator Induced Lung Injury: Comparative Effects with an Inhaled Corticosteroid

BACKGROUND: Ventilator-induced lung injury (VILI) is a side effect of mechanical ventilation. Lung inflammation and pulmonary activation of coagulation are induced by mechanical stress. Clinical and preclinical studies show that heparin possesses anti-inflammatory properties. Therefore, we assessed...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghiasi, Farzin, Sadeghian, Mohsen, Emami, Mohammad, Kiaie, Babak Ali, Mousavi, Sarah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5672667/
https://www.ncbi.nlm.nih.gov/pubmed/29142373
http://dx.doi.org/10.4103/ijccm.IJCCM_183_17
Descripción
Sumario:BACKGROUND: Ventilator-induced lung injury (VILI) is a side effect of mechanical ventilation. Lung inflammation and pulmonary activation of coagulation are induced by mechanical stress. Clinical and preclinical studies show that heparin possesses anti-inflammatory properties. Therefore, we assessed the effects of nebulized heparin in VILI. METHODS: Sixty critically ill adult patients who require mechanical ventilation for more than 48 h were included in this prospective, nonrandomized controlled study. Patients received nebulized heparin (10,000 U every 6 h) for 5 days. The matched control group received nebulized budesonide as routine practice in our center. This study assessed changes in partial pressure of oxygen to inspired fraction of oxygen ratio (PaO(2)/FiO(2)) and rapid shallow breathing index (RSBI) during the study as primary endpoints. RESULTS: The average daily PaO(2)/FiO(2) ratio was not statistically significant between both groups (187 ± 11.6 vs. 171 ± 11.6, P = 0.35). The RSBI also did not differ between groups (P = 0.58). Heparin administration was associated with a higher number of ventilator-free days among survivors but not significantly (7.7 ± 10.6 vs. 5.1 ± 8, 95% confidence interval − 2.2–7.5, P = 0.28). Successful weaning from mechanical ventilation was higher in the heparin group (P = 0.42). We did not observe any serious or increased adverse effects from nebulized heparin. CONCLUSION: The results of this study show that the overall effectiveness of nebulized heparin is at least as comparable with a potent corticosteroid (budesonide). Heparin could be a safe and effective modality for patients who at risk of VILI.