Cargando…
Gadobutrol versus gadofosveset-trisodium in MR venography of the lower extremities
OBJECTIVES: MR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protoco...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5674132/ https://www.ncbi.nlm.nih.gov/pubmed/28674964 http://dx.doi.org/10.1007/s00330-017-4902-0 |
Sumario: | OBJECTIVES: MR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protocols hamper everyday practice. MATERIALS: 20 patients (11 men; mean age 54 ± 11.8 years; body mass index 23.6 ± 2.5) were enrolled in this prospective study. An intra-individual comparison of image quality, interpretation and findings for two different contrast agents (regular gadolinium contrast agent gadobutrol vs. bloodpool contrast agent gadofosveset-trisodium) and two different scan protocols (long acquisition time protocol using a high-resolution fast field echo (FFE) sequence vs. short acquisition time protocol using an ultra-fast gradient echo (GE) sequence) were performed. RESULTS: Image quality (average of 4.94 vs. 4.92 on a five-point scale), interpretation and contrast-to-noise ratio (44 vs. 45) were equal for both contrast agents. Image findings showed no statistical significant differences between the MR protocols or contrast agents (overall p = 0.328). CONCLUSIONS: For high-resolution MRV, it is possible to replace gadofosveset-trisodium with gadobutrol. Furthermore, an ultra-fast GE sequence for MRV might considerably shorten acquisition time, without loss of image quality or diagnostic yield. KEY POINTS: • High-quality MRV can be performed with a regular gadolinium-based contrast agent. • Ultra-fast GRE vs. HR-FFE MRV: equally suitable for evaluation of venous obstruction. • Regular gadolinium-based contrast agent can supersede a bloodpool contrast agent for MRV. • Equal confidence for gadobutrol vs gadofosveset-trisodium in MRV. • MRV accessible for routine daily practice. |
---|