Cargando…

Camera Calibration Robust to Defocus Using Phase-Shifting Patterns

Camera parameters can’t be estimated accurately using traditional calibration methods if the camera is substantially defocused. To tackle this problem, an improved approach based on three phase-shifting circular grating (PCG) arrays is proposed in this paper. Rather than encoding the feature points...

Descripción completa

Detalles Bibliográficos
Autores principales: Cai, Bolin, Wang, Yuwei, Wang, Keyi, Ma, Mengchao, Chen, Xiangcheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5676954/
https://www.ncbi.nlm.nih.gov/pubmed/29035329
http://dx.doi.org/10.3390/s17102361
_version_ 1783277151646121984
author Cai, Bolin
Wang, Yuwei
Wang, Keyi
Ma, Mengchao
Chen, Xiangcheng
author_facet Cai, Bolin
Wang, Yuwei
Wang, Keyi
Ma, Mengchao
Chen, Xiangcheng
author_sort Cai, Bolin
collection PubMed
description Camera parameters can’t be estimated accurately using traditional calibration methods if the camera is substantially defocused. To tackle this problem, an improved approach based on three phase-shifting circular grating (PCG) arrays is proposed in this paper. Rather than encoding the feature points into the intensity, the proposed method encodes the feature points into the phase distribution, which can be recovered precisely using phase-shifting methods. The PCG centers are extracted as feature points, which can be located accurately even if the images are severely blurred. Unlike the previous method which just uses a single circle, the proposed method uses a concentric circle to estimate the PCG center, such that the center can be located precisely. This paper also presents a sorting algorithm for the detected feature points automatically. Experiments with both synthetic and real images were carried out to validate the performance of the method. And the results show that the superiority of PCG arrays compared with the concentric circle array even under severe defocus.
format Online
Article
Text
id pubmed-5676954
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-56769542017-11-17 Camera Calibration Robust to Defocus Using Phase-Shifting Patterns Cai, Bolin Wang, Yuwei Wang, Keyi Ma, Mengchao Chen, Xiangcheng Sensors (Basel) Article Camera parameters can’t be estimated accurately using traditional calibration methods if the camera is substantially defocused. To tackle this problem, an improved approach based on three phase-shifting circular grating (PCG) arrays is proposed in this paper. Rather than encoding the feature points into the intensity, the proposed method encodes the feature points into the phase distribution, which can be recovered precisely using phase-shifting methods. The PCG centers are extracted as feature points, which can be located accurately even if the images are severely blurred. Unlike the previous method which just uses a single circle, the proposed method uses a concentric circle to estimate the PCG center, such that the center can be located precisely. This paper also presents a sorting algorithm for the detected feature points automatically. Experiments with both synthetic and real images were carried out to validate the performance of the method. And the results show that the superiority of PCG arrays compared with the concentric circle array even under severe defocus. MDPI 2017-10-16 /pmc/articles/PMC5676954/ /pubmed/29035329 http://dx.doi.org/10.3390/s17102361 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cai, Bolin
Wang, Yuwei
Wang, Keyi
Ma, Mengchao
Chen, Xiangcheng
Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title_full Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title_fullStr Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title_full_unstemmed Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title_short Camera Calibration Robust to Defocus Using Phase-Shifting Patterns
title_sort camera calibration robust to defocus using phase-shifting patterns
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5676954/
https://www.ncbi.nlm.nih.gov/pubmed/29035329
http://dx.doi.org/10.3390/s17102361
work_keys_str_mv AT caibolin cameracalibrationrobusttodefocususingphaseshiftingpatterns
AT wangyuwei cameracalibrationrobusttodefocususingphaseshiftingpatterns
AT wangkeyi cameracalibrationrobusttodefocususingphaseshiftingpatterns
AT mamengchao cameracalibrationrobusttodefocususingphaseshiftingpatterns
AT chenxiangcheng cameracalibrationrobusttodefocususingphaseshiftingpatterns