Cargando…
Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures
Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the support...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5679570/ https://www.ncbi.nlm.nih.gov/pubmed/29138601 http://dx.doi.org/10.2147/CCIDE.S146544 |
_version_ | 1783277601723252736 |
---|---|
author | Flanagan, Dennis |
author_facet | Flanagan, Dennis |
author_sort | Flanagan, Dennis |
collection | PubMed |
description | Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the supporting implants or friction upon seating of the prosthesis. This gap is filled with cement for retention of the prosthesis. Any lateral pressure may cause marginal bone loss or periimplantitis. Also, there is usually a microscopic gap at the margin of a crown retainer that exposes the cement to oral fluids. The solubility of zinc phosphate (ZOP) cement is a definite liability due to the risk for cement dissolution. In fixed prostheses, the dissolution of the cement of one or more retainers would cause a transfer of the occlusal load to the retained unit(s). The resulting rotation and lifting of the cement-retained implants from occlusal and parafunctional loads could cause loss of osseointegration of the abutment-retained implant(s). ZOP cement may not be indicated for implant-supported fixed partial dentures or splints. Cement dissolution in single unit probably only involves re-cementation, if the patient does not swallow or aspirate the crown. |
format | Online Article Text |
id | pubmed-5679570 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-56795702017-11-14 Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures Flanagan, Dennis Clin Cosmet Investig Dent Case Series Implant-supported dental prostheses can be retained by a screw or cement. Implant-supported fixed partial dentures have a passive fit. A passive fit means there is an internal gap between the abutment surface and the intaglio of the retainer to insure that there is no lateral pressure on the supporting implants or friction upon seating of the prosthesis. This gap is filled with cement for retention of the prosthesis. Any lateral pressure may cause marginal bone loss or periimplantitis. Also, there is usually a microscopic gap at the margin of a crown retainer that exposes the cement to oral fluids. The solubility of zinc phosphate (ZOP) cement is a definite liability due to the risk for cement dissolution. In fixed prostheses, the dissolution of the cement of one or more retainers would cause a transfer of the occlusal load to the retained unit(s). The resulting rotation and lifting of the cement-retained implants from occlusal and parafunctional loads could cause loss of osseointegration of the abutment-retained implant(s). ZOP cement may not be indicated for implant-supported fixed partial dentures or splints. Cement dissolution in single unit probably only involves re-cementation, if the patient does not swallow or aspirate the crown. Dove Medical Press 2017-11-03 /pmc/articles/PMC5679570/ /pubmed/29138601 http://dx.doi.org/10.2147/CCIDE.S146544 Text en © 2017 Flanagan. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Case Series Flanagan, Dennis Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title | Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title_full | Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title_fullStr | Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title_full_unstemmed | Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title_short | Zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
title_sort | zinc phosphate as a definitive cement for implant-supported crowns and fixed dentures |
topic | Case Series |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5679570/ https://www.ncbi.nlm.nih.gov/pubmed/29138601 http://dx.doi.org/10.2147/CCIDE.S146544 |
work_keys_str_mv | AT flanagandennis zincphosphateasadefinitivecementforimplantsupportedcrownsandfixeddentures |