Cargando…

Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer

BACKGROUND: Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for panc...

Descripción completa

Detalles Bibliográficos
Autores principales: Karava, Konstantina, Ehrbar, Stefanie, Riesterer, Oliver, Roesch, Johannes, Glatz, Stefan, Klöck, Stephan, Guckenberger, Matthias, Tanadini-Lang, Stephanie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680781/
https://www.ncbi.nlm.nih.gov/pubmed/29121945
http://dx.doi.org/10.1186/s13014-017-0906-9
_version_ 1783277826428895232
author Karava, Konstantina
Ehrbar, Stefanie
Riesterer, Oliver
Roesch, Johannes
Glatz, Stefan
Klöck, Stephan
Guckenberger, Matthias
Tanadini-Lang, Stephanie
author_facet Karava, Konstantina
Ehrbar, Stefanie
Riesterer, Oliver
Roesch, Johannes
Glatz, Stefan
Klöck, Stephan
Guckenberger, Matthias
Tanadini-Lang, Stephanie
author_sort Karava, Konstantina
collection PubMed
description BACKGROUND: Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. METHODS AND MATERIALS: Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. RESULTS: Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. CONCLUSIONS: By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.
format Online
Article
Text
id pubmed-5680781
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56807812017-11-17 Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer Karava, Konstantina Ehrbar, Stefanie Riesterer, Oliver Roesch, Johannes Glatz, Stefan Klöck, Stephan Guckenberger, Matthias Tanadini-Lang, Stephanie Radiat Oncol Research BACKGROUND: Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. METHODS AND MATERIALS: Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. RESULTS: Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. CONCLUSIONS: By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific. BioMed Central 2017-11-09 /pmc/articles/PMC5680781/ /pubmed/29121945 http://dx.doi.org/10.1186/s13014-017-0906-9 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License(http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Karava, Konstantina
Ehrbar, Stefanie
Riesterer, Oliver
Roesch, Johannes
Glatz, Stefan
Klöck, Stephan
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title_full Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title_fullStr Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title_full_unstemmed Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title_short Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
title_sort potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680781/
https://www.ncbi.nlm.nih.gov/pubmed/29121945
http://dx.doi.org/10.1186/s13014-017-0906-9
work_keys_str_mv AT karavakonstantina potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT ehrbarstefanie potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT riestereroliver potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT roeschjohannes potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT glatzstefan potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT klockstephan potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT guckenbergermatthias potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer
AT tanadinilangstephanie potentialdosimetricbenefitsofadaptivetumortrackingovertheinternaltargetvolumeconceptforstereotacticbodyradiationtherapyofpancreaticcancer