Cargando…

Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population

OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND M...

Descripción completa

Detalles Bibliográficos
Autores principales: Grover-Páez, Fernando, Cardona-Muñoz, Ernesto G., Cardona-Müller, David, Guzmán-Saldívar, Víctor H., Rodríguez-De la Cerda, Mariana, Jiménez-Cázarez, Mayra B., Totsuka-Sutto, Sylvia E., Alanis-Sánchez, Guillermo A., Ramos-Becerra, Carlos G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680989/
https://www.ncbi.nlm.nih.gov/pubmed/28945665
http://dx.doi.org/10.1097/MBP.0000000000000290
_version_ 1783277871074115584
author Grover-Páez, Fernando
Cardona-Muñoz, Ernesto G.
Cardona-Müller, David
Guzmán-Saldívar, Víctor H.
Rodríguez-De la Cerda, Mariana
Jiménez-Cázarez, Mayra B.
Totsuka-Sutto, Sylvia E.
Alanis-Sánchez, Guillermo A.
Ramos-Becerra, Carlos G.
author_facet Grover-Páez, Fernando
Cardona-Muñoz, Ernesto G.
Cardona-Müller, David
Guzmán-Saldívar, Víctor H.
Rodríguez-De la Cerda, Mariana
Jiménez-Cázarez, Mayra B.
Totsuka-Sutto, Sylvia E.
Alanis-Sánchez, Guillermo A.
Ramos-Becerra, Carlos G.
author_sort Grover-Páez, Fernando
collection PubMed
description OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97–190), diastolic BP was 90.9±12.9 mmHg (range: 68–120), and arm circumference was 30.8±4 cm (range: 25–38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol.
format Online
Article
Text
id pubmed-5680989
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-56809892017-11-22 Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population Grover-Páez, Fernando Cardona-Muñoz, Ernesto G. Cardona-Müller, David Guzmán-Saldívar, Víctor H. Rodríguez-De la Cerda, Mariana Jiménez-Cázarez, Mayra B. Totsuka-Sutto, Sylvia E. Alanis-Sánchez, Guillermo A. Ramos-Becerra, Carlos G. Blood Press Monit Devices and Technology OBJECTIVE: The aim of this study was to determine the accuracy of the Omron HEM-7320-LA with Intelli Wrap technology cuff HEM-FL1 for self-measurement and clinic blood pressure (BP) measurement according to the European Society of Hypertension International Protocol revision 2010. PARTICIPANTS AND METHODS: The evaluation was performed in 39 individuals. The mean age of the participants was 47.9±14 years; systolic BP was 145.2±24.3 mmHg (range: 97–190), diastolic BP was 90.9±12.9 mmHg (range: 68–120), and arm circumference was 30.8±4 cm (range: 25–38.5). RESULTS: The device successfully fulfilled the established criteria of the validation protocol. The device overestimated systolic BP by 0.6±5.7 mmHg and diastolic BP by 2.2±5.1 mmHg. The specially designed cuff HEM-FL1 to cover a broad range of arm circumferences and self-placement fulfilled the requirements of the International Protocol. Lippincott Williams & Wilkins 2017-12 2017-09-22 /pmc/articles/PMC5680989/ /pubmed/28945665 http://dx.doi.org/10.1097/MBP.0000000000000290 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Devices and Technology
Grover-Páez, Fernando
Cardona-Muñoz, Ernesto G.
Cardona-Müller, David
Guzmán-Saldívar, Víctor H.
Rodríguez-De la Cerda, Mariana
Jiménez-Cázarez, Mayra B.
Totsuka-Sutto, Sylvia E.
Alanis-Sánchez, Guillermo A.
Ramos-Becerra, Carlos G.
Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title_full Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title_fullStr Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title_full_unstemmed Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title_short Validation of the Omron HEM-7320-LA, upper arm blood pressure monitor with Intelli Wrap Technology Cuff HEM-FL1 for self-measurement and clinic use according to the European Society of Hypertension International Protocol revision 2010 in the Mexican population
title_sort validation of the omron hem-7320-la, upper arm blood pressure monitor with intelli wrap technology cuff hem-fl1 for self-measurement and clinic use according to the european society of hypertension international protocol revision 2010 in the mexican population
topic Devices and Technology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5680989/
https://www.ncbi.nlm.nih.gov/pubmed/28945665
http://dx.doi.org/10.1097/MBP.0000000000000290
work_keys_str_mv AT groverpaezfernando validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT cardonamunozernestog validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT cardonamullerdavid validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT guzmansaldivarvictorh validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT rodriguezdelacerdamariana validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT jimenezcazarezmayrab validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT totsukasuttosylviae validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT alanissanchezguillermoa validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation
AT ramosbecerracarlosg validationoftheomronhem7320laupperarmbloodpressuremonitorwithintelliwraptechnologycuffhemfl1forselfmeasurementandclinicuseaccordingtotheeuropeansocietyofhypertensioninternationalprotocolrevision2010inthemexicanpopulation