In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals
OBJECTIVES: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. MATERIALS AND METHODS: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide pa...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Conservative Dentistry
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5682144/ https://www.ncbi.nlm.nih.gov/pubmed/29142876 http://dx.doi.org/10.5395/rde.2017.42.4.282 |
_version_ | 1783278047180357632 |
---|---|
author | Yılmaz, Koray Uslu, Gülşah Özyürek, Taha |
author_facet | Yılmaz, Koray Uslu, Gülşah Özyürek, Taha |
author_sort | Yılmaz, Koray |
collection | PubMed |
description | OBJECTIVES: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. MATERIALS AND METHODS: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). RESULTS: In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). CONCLUSIONS: Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals. |
format | Online Article Text |
id | pubmed-5682144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Academy of Conservative Dentistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-56821442017-11-15 In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals Yılmaz, Koray Uslu, Gülşah Özyürek, Taha Restor Dent Endod Research Article OBJECTIVES: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. MATERIALS AND METHODS: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). RESULTS: In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). CONCLUSIONS: Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals. The Korean Academy of Conservative Dentistry 2017-11 2017-10-30 /pmc/articles/PMC5682144/ /pubmed/29142876 http://dx.doi.org/10.5395/rde.2017.42.4.282 Text en Copyright © 2017. The Korean Academy of Conservative Dentistry https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Yılmaz, Koray Uslu, Gülşah Özyürek, Taha In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title | In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title_full | In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title_fullStr | In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title_full_unstemmed | In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title_short | In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals |
title_sort | in vitro comparison of the cyclic fatigue resistance of hyflex edm, one g, and proglider nickel titanium glide path instruments in single and double curvature canals |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5682144/ https://www.ncbi.nlm.nih.gov/pubmed/29142876 http://dx.doi.org/10.5395/rde.2017.42.4.282 |
work_keys_str_mv | AT yılmazkoray invitrocomparisonofthecyclicfatigueresistanceofhyflexedmonegandproglidernickeltitaniumglidepathinstrumentsinsingleanddoublecurvaturecanals AT uslugulsah invitrocomparisonofthecyclicfatigueresistanceofhyflexedmonegandproglidernickeltitaniumglidepathinstrumentsinsingleanddoublecurvaturecanals AT ozyurektaha invitrocomparisonofthecyclicfatigueresistanceofhyflexedmonegandproglidernickeltitaniumglidepathinstrumentsinsingleanddoublecurvaturecanals |