Cargando…

“Low platelet usage” haematology laboratories: To store or not to store?

In the UK, hospitals with annual platelet use of less than 500 pools, like our institution, usually do not store platelets on-site and these are only ordered from the national blood service (NBS) when a transfusion is required. In 2016, we piloted routine on-site storage of one pool of A RhD negativ...

Descripción completa

Detalles Bibliográficos
Autores principales: Elmi, M., Sirigireddy, B., Abukar, J., Tchipeva, D., Chauhan, N., Tsitsikas, D. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5683636/
https://www.ncbi.nlm.nih.gov/pubmed/29131870
http://dx.doi.org/10.1371/journal.pone.0187340
Descripción
Sumario:In the UK, hospitals with annual platelet use of less than 500 pools, like our institution, usually do not store platelets on-site and these are only ordered from the national blood service (NBS) when a transfusion is required. In 2016, we piloted routine on-site storage of one pool of A RhD negative PLT. Data were collected retrospectively on units of PLTs ordered from NBS, units transfused to patients, wastage, requirements for emergency deliveries from NBS and overall cost. These were compared to corresponding data from the four preceding years (2012–2015). There was a 39% reduction in the PLT ordered from NBS in 2016 compared to previous years and a 50% reduction in transfused PLT. Annual wastage for 2016 increased by 23% even though the absolute number of wasted PLT did not alter significantly. Annual cost reduced by 36% in 2016 resulting from reduction in the total amount of PLTs ordered as well as reduction in emergency deliveries.