Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy

The purpose of this study was to determine if heat exposure alters the measures of total body water (TBW), extracellular water (ECW), and intracellular water (ICW) in both single-frequency bioelectrical impedance analysis (BIA) and bioimpedance spectroscopy (BIS). Additionally, we sought to determin...

Descripción completa

Detalles Bibliográficos
Autores principales: NICKERSON, BRETT S., ESCO, MICHAEL R., BISHOP, PHILLIP A., KLISZCZEWICZ, BRIAN M., WILLIFORD, HENRY N., PARK, KYUNG-SHIN, WELBORN, BAILEY A., SNARR, RONALD L., TOLUSSO, DANILO V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Berkeley Electronic Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5685079/
https://www.ncbi.nlm.nih.gov/pubmed/29170709
_version_ 1783278585870548992
author NICKERSON, BRETT S.
ESCO, MICHAEL R.
BISHOP, PHILLIP A.
KLISZCZEWICZ, BRIAN M.
WILLIFORD, HENRY N.
PARK, KYUNG-SHIN
WELBORN, BAILEY A.
SNARR, RONALD L.
TOLUSSO, DANILO V.
author_facet NICKERSON, BRETT S.
ESCO, MICHAEL R.
BISHOP, PHILLIP A.
KLISZCZEWICZ, BRIAN M.
WILLIFORD, HENRY N.
PARK, KYUNG-SHIN
WELBORN, BAILEY A.
SNARR, RONALD L.
TOLUSSO, DANILO V.
author_sort NICKERSON, BRETT S.
collection PubMed
description The purpose of this study was to determine if heat exposure alters the measures of total body water (TBW), extracellular water (ECW), and intracellular water (ICW) in both single-frequency bioelectrical impedance analysis (BIA) and bioimpedance spectroscopy (BIS). Additionally, we sought to determine if any differences exist between the BIA and BIS techniques before and after brief exposure to heat. Body water was evaluated for twenty men (age=24±4 years) in a thermoneutral environment (22°C) before (PRE) and immediately after (POST) 15 min of passive heating (35°C) in an environmental chamber. The mean difference and 95% limits of agreement at PRE demonstrated that BIS yielded significantly higher body water values than BIA (all p<0.05; TBW=1.8kg; ECW=0.6±1.3kg; ICW=1.2±3.7kg). However, the effect size (ES) of the mean differences at PRE were small and the r-values were high (r≥0.97). TBW and ICW remained significantly higher at POST for BIS (both p<0.05; 1.4±3.2kg and 1.1±3.7kg, respectively) whereas ECW was not different (p>0.05; 0.2±1.5kg). Additionally, the ES of the mean differences at POST were trivial to small and the r-values were high (r≥0.96). When analyzing the changes in body water before and after heat exposure, POST values for BIS were significantly higher than PRE (all p<0.001; TBW=0.6±0.8kg; ECW=0.4±0.3kg; ICW=0.3±0.6kg). Similarly, POST values for BIA were significantly higher than PRE (all p<0.001; TBW=1.0±0.6kg; ECW=0.7±0.4kg; ICW=0.4±0.4kg). BIA and BIS provide similar body water estimates. However, the increase in POST body water values indicate more research is needed before either method can be used for estimating body water after heat exposure.
format Online
Article
Text
id pubmed-5685079
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Berkeley Electronic Press
record_format MEDLINE/PubMed
spelling pubmed-56850792017-11-21 Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy NICKERSON, BRETT S. ESCO, MICHAEL R. BISHOP, PHILLIP A. KLISZCZEWICZ, BRIAN M. WILLIFORD, HENRY N. PARK, KYUNG-SHIN WELBORN, BAILEY A. SNARR, RONALD L. TOLUSSO, DANILO V. Int J Exerc Sci Original Research The purpose of this study was to determine if heat exposure alters the measures of total body water (TBW), extracellular water (ECW), and intracellular water (ICW) in both single-frequency bioelectrical impedance analysis (BIA) and bioimpedance spectroscopy (BIS). Additionally, we sought to determine if any differences exist between the BIA and BIS techniques before and after brief exposure to heat. Body water was evaluated for twenty men (age=24±4 years) in a thermoneutral environment (22°C) before (PRE) and immediately after (POST) 15 min of passive heating (35°C) in an environmental chamber. The mean difference and 95% limits of agreement at PRE demonstrated that BIS yielded significantly higher body water values than BIA (all p<0.05; TBW=1.8kg; ECW=0.6±1.3kg; ICW=1.2±3.7kg). However, the effect size (ES) of the mean differences at PRE were small and the r-values were high (r≥0.97). TBW and ICW remained significantly higher at POST for BIS (both p<0.05; 1.4±3.2kg and 1.1±3.7kg, respectively) whereas ECW was not different (p>0.05; 0.2±1.5kg). Additionally, the ES of the mean differences at POST were trivial to small and the r-values were high (r≥0.96). When analyzing the changes in body water before and after heat exposure, POST values for BIS were significantly higher than PRE (all p<0.001; TBW=0.6±0.8kg; ECW=0.4±0.3kg; ICW=0.3±0.6kg). Similarly, POST values for BIA were significantly higher than PRE (all p<0.001; TBW=1.0±0.6kg; ECW=0.7±0.4kg; ICW=0.4±0.4kg). BIA and BIS provide similar body water estimates. However, the increase in POST body water values indicate more research is needed before either method can be used for estimating body water after heat exposure. Berkeley Electronic Press 2017-11-01 /pmc/articles/PMC5685079/ /pubmed/29170709 Text en
spellingShingle Original Research
NICKERSON, BRETT S.
ESCO, MICHAEL R.
BISHOP, PHILLIP A.
KLISZCZEWICZ, BRIAN M.
WILLIFORD, HENRY N.
PARK, KYUNG-SHIN
WELBORN, BAILEY A.
SNARR, RONALD L.
TOLUSSO, DANILO V.
Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title_full Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title_fullStr Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title_full_unstemmed Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title_short Effects of Heat Exposure on Body Water Assessed using Single-Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy
title_sort effects of heat exposure on body water assessed using single-frequency bioelectrical impedance analysis and bioimpedance spectroscopy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5685079/
https://www.ncbi.nlm.nih.gov/pubmed/29170709
work_keys_str_mv AT nickersonbretts effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT escomichaelr effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT bishopphillipa effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT kliszczewiczbrianm effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT willifordhenryn effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT parkkyungshin effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT welbornbaileya effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT snarrronaldl effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy
AT tolussodanilov effectsofheatexposureonbodywaterassessedusingsinglefrequencybioelectricalimpedanceanalysisandbioimpedancespectroscopy