Cargando…

drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis

Multiplex bead-based immunoassays are used to measure concentrations of several analytes simultaneously. These assays include control standard curves (SC) to reduce between-plate variability and normalize quantitation of analytes of biological samples. Suboptimal calibration might result in large ra...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanz, Hector, Aponte, John J., Harezlak, Jaroslaw, Dong, Yan, Ayestaran, Aintzane, Nhabomba, Augusto, Mpina, Maxmillian, Maurin, Obiang Régis, Díez-Padrisa, Núria, Aguilar, Ruth, Moncunill, Gemma, Selidji Todagbe, Agnandij, Daubenberger, Claudia, Dobaño, Carlota, Valim, Clarissa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5685631/
https://www.ncbi.nlm.nih.gov/pubmed/29136653
http://dx.doi.org/10.1371/journal.pone.0187901
_version_ 1783278658220195840
author Sanz, Hector
Aponte, John J.
Harezlak, Jaroslaw
Dong, Yan
Ayestaran, Aintzane
Nhabomba, Augusto
Mpina, Maxmillian
Maurin, Obiang Régis
Díez-Padrisa, Núria
Aguilar, Ruth
Moncunill, Gemma
Selidji Todagbe, Agnandij
Daubenberger, Claudia
Dobaño, Carlota
Valim, Clarissa
author_facet Sanz, Hector
Aponte, John J.
Harezlak, Jaroslaw
Dong, Yan
Ayestaran, Aintzane
Nhabomba, Augusto
Mpina, Maxmillian
Maurin, Obiang Régis
Díez-Padrisa, Núria
Aguilar, Ruth
Moncunill, Gemma
Selidji Todagbe, Agnandij
Daubenberger, Claudia
Dobaño, Carlota
Valim, Clarissa
author_sort Sanz, Hector
collection PubMed
description Multiplex bead-based immunoassays are used to measure concentrations of several analytes simultaneously. These assays include control standard curves (SC) to reduce between-plate variability and normalize quantitation of analytes of biological samples. Suboptimal calibration might result in large random error and decreased number of samples with analyte concentrations within the limits of quantification. Suboptimal calibration may be a consequence of poor fitness of the functions used for the SC, the treatment of the background noise and the method used to estimate the limits of quantification. Currently assessment of fitness of curves is largely dependent on operator and that may add additional error. Moreover, there is no software to automate data managing and quality control. In this article we present a R package, drLumi, with functions for managing data, calibrating assays and performing quality control. To optimize the assay the package implements: i) three dose-response functions, ii) four approaches for treating background noise and iii) three methods for estimating limits of quantifications. Other implemented functions are focused on the quality control of the fitted standard curve: detection of outliers, estimation of the confidence or prediction interval, and estimation of summary statistics. With demonstration purpose, we apply the software to 30 cytokines, chemokines and growth factors measured in a multiplex bead-based immunoassay in a study aiming to measure correlates of risk or protection from malaria of the RTS,S malaria vaccine nested in the Phase 3 randomized controlled trial of this vaccine.
format Online
Article
Text
id pubmed-5685631
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56856312017-11-30 drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis Sanz, Hector Aponte, John J. Harezlak, Jaroslaw Dong, Yan Ayestaran, Aintzane Nhabomba, Augusto Mpina, Maxmillian Maurin, Obiang Régis Díez-Padrisa, Núria Aguilar, Ruth Moncunill, Gemma Selidji Todagbe, Agnandij Daubenberger, Claudia Dobaño, Carlota Valim, Clarissa PLoS One Research Article Multiplex bead-based immunoassays are used to measure concentrations of several analytes simultaneously. These assays include control standard curves (SC) to reduce between-plate variability and normalize quantitation of analytes of biological samples. Suboptimal calibration might result in large random error and decreased number of samples with analyte concentrations within the limits of quantification. Suboptimal calibration may be a consequence of poor fitness of the functions used for the SC, the treatment of the background noise and the method used to estimate the limits of quantification. Currently assessment of fitness of curves is largely dependent on operator and that may add additional error. Moreover, there is no software to automate data managing and quality control. In this article we present a R package, drLumi, with functions for managing data, calibrating assays and performing quality control. To optimize the assay the package implements: i) three dose-response functions, ii) four approaches for treating background noise and iii) three methods for estimating limits of quantifications. Other implemented functions are focused on the quality control of the fitted standard curve: detection of outliers, estimation of the confidence or prediction interval, and estimation of summary statistics. With demonstration purpose, we apply the software to 30 cytokines, chemokines and growth factors measured in a multiplex bead-based immunoassay in a study aiming to measure correlates of risk or protection from malaria of the RTS,S malaria vaccine nested in the Phase 3 randomized controlled trial of this vaccine. Public Library of Science 2017-11-14 /pmc/articles/PMC5685631/ /pubmed/29136653 http://dx.doi.org/10.1371/journal.pone.0187901 Text en © 2017 Sanz et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Sanz, Hector
Aponte, John J.
Harezlak, Jaroslaw
Dong, Yan
Ayestaran, Aintzane
Nhabomba, Augusto
Mpina, Maxmillian
Maurin, Obiang Régis
Díez-Padrisa, Núria
Aguilar, Ruth
Moncunill, Gemma
Selidji Todagbe, Agnandij
Daubenberger, Claudia
Dobaño, Carlota
Valim, Clarissa
drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title_full drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title_fullStr drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title_full_unstemmed drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title_short drLumi: An open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
title_sort drlumi: an open-source package to manage data, calibrate, and conduct quality control of multiplex bead-based immunoassays data analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5685631/
https://www.ncbi.nlm.nih.gov/pubmed/29136653
http://dx.doi.org/10.1371/journal.pone.0187901
work_keys_str_mv AT sanzhector drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT apontejohnj drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT harezlakjaroslaw drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT dongyan drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT ayestaranaintzane drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT nhabombaaugusto drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT mpinamaxmillian drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT maurinobiangregis drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT diezpadrisanuria drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT aguilarruth drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT moncunillgemma drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT selidjitodagbeagnandij drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT daubenbergerclaudia drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT dobanocarlota drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis
AT valimclarissa drlumianopensourcepackagetomanagedatacalibrateandconductqualitycontrolofmultiplexbeadbasedimmunoassaysdataanalysis