Cargando…

Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET

BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However...

Descripción completa

Detalles Bibliográficos
Autores principales: Nordström, Jonny, Kero, Tanja, Harms, Hendrik Johannes, Widström, Charles, Flachskampf, Frank A., Sörensen, Jens, Lubberink, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5686036/
https://www.ncbi.nlm.nih.gov/pubmed/29138942
http://dx.doi.org/10.1186/s40658-017-0195-2
_version_ 1783278701464518656
author Nordström, Jonny
Kero, Tanja
Harms, Hendrik Johannes
Widström, Charles
Flachskampf, Frank A.
Sörensen, Jens
Lubberink, Mark
author_facet Nordström, Jonny
Kero, Tanja
Harms, Hendrik Johannes
Widström, Charles
Flachskampf, Frank A.
Sörensen, Jens
Lubberink, Mark
author_sort Nordström, Jonny
collection PubMed
description BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V (B)) (15)O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated (15)O-water PET/CT scan and cardiac MRI. V (B) and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V (B) and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. RESULTS: Using V (B) images, high correlations between PET and MRI ESV (r = 0.89, p < 0.001), EDV (r = 0.85, p < 0.001), SV (r = 0.74, p = 0.006) and LVEF (r = 0.72, p = 0.008) were found for the volume-based method. Correlations for FP images were slightly, but not significantly, lower than those for V (B) images when compared to MRI. Surface- and count-based methods showed no significant difference compared with the volume-based correlations with MRI. The volume-based method showed the best agreement with MRI with no significant difference on average for EDV and LVEF but with an overestimation of values for ESV (14%, p = 0.005) and SV (18%, p = 0.004) when using V (B) images. Using FP images, none of the parameters showed a significant difference from MRI. Inter-operator repeatability was excellent for all parameters (ICC > 0.86, p < 0.001). CONCLUSION: Calculation of LV volumes and LVEF from dynamic (15)O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.
format Online
Article
Text
id pubmed-5686036
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-56860362017-12-01 Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET Nordström, Jonny Kero, Tanja Harms, Hendrik Johannes Widström, Charles Flachskampf, Frank A. Sörensen, Jens Lubberink, Mark EJNMMI Phys Original Research BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). (15)O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard (15)O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V (B)) (15)O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated (15)O-water PET/CT scan and cardiac MRI. V (B) and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V (B) and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. RESULTS: Using V (B) images, high correlations between PET and MRI ESV (r = 0.89, p < 0.001), EDV (r = 0.85, p < 0.001), SV (r = 0.74, p = 0.006) and LVEF (r = 0.72, p = 0.008) were found for the volume-based method. Correlations for FP images were slightly, but not significantly, lower than those for V (B) images when compared to MRI. Surface- and count-based methods showed no significant difference compared with the volume-based correlations with MRI. The volume-based method showed the best agreement with MRI with no significant difference on average for EDV and LVEF but with an overestimation of values for ESV (14%, p = 0.005) and SV (18%, p = 0.004) when using V (B) images. Using FP images, none of the parameters showed a significant difference from MRI. Inter-operator repeatability was excellent for all parameters (ICC > 0.86, p < 0.001). CONCLUSION: Calculation of LV volumes and LVEF from dynamic (15)O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting. Springer International Publishing 2017-11-14 /pmc/articles/PMC5686036/ /pubmed/29138942 http://dx.doi.org/10.1186/s40658-017-0195-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Nordström, Jonny
Kero, Tanja
Harms, Hendrik Johannes
Widström, Charles
Flachskampf, Frank A.
Sörensen, Jens
Lubberink, Mark
Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title_full Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title_fullStr Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title_full_unstemmed Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title_short Calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)O-water PET/CT: 5D-PET
title_sort calculation of left ventricular volumes and ejection fraction from dynamic cardiac-gated (15)o-water pet/ct: 5d-pet
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5686036/
https://www.ncbi.nlm.nih.gov/pubmed/29138942
http://dx.doi.org/10.1186/s40658-017-0195-2
work_keys_str_mv AT nordstromjonny calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT kerotanja calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT harmshendrikjohannes calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT widstromcharles calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT flachskampffranka calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT sorensenjens calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet
AT lubberinkmark calculationofleftventricularvolumesandejectionfractionfromdynamiccardiacgated15owaterpetct5dpet