Cargando…
Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm
Endoscopic optical coherence tomography (OCT) has emerged as a valuable tool for advancing our understanding of the histomorphology of various internal luminal organs and studying the pathogenesis of relevant diseases. To date, this technology affords limited resolving power for discerning subtle pa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5688175/ https://www.ncbi.nlm.nih.gov/pubmed/29142274 http://dx.doi.org/10.1038/s41467-017-01494-4 |
_version_ | 1783279103057592320 |
---|---|
author | Yuan, Wu Brown, Robert Mitzner, Wayne Yarmus, Lonny Li, Xingde |
author_facet | Yuan, Wu Brown, Robert Mitzner, Wayne Yarmus, Lonny Li, Xingde |
author_sort | Yuan, Wu |
collection | PubMed |
description | Endoscopic optical coherence tomography (OCT) has emerged as a valuable tool for advancing our understanding of the histomorphology of various internal luminal organs and studying the pathogenesis of relevant diseases. To date, this technology affords limited resolving power for discerning subtle pathological changes associated with early diseases. In addition, it remains challenging to access small luminal organs or pass through narrow luminal sections without potentially causing trauma to tissue with a traditional OCT endoscope of a 1-1.5 mm diameter. Here we report an ultracompact (520 µm in outer diameter and 5 mm in rigid length) and super-achromatic microprobe made with a built-in monolithic fiber-optic ball lens, which achieves ultrahigh-resolution (1.7 µm axial resolution in tissue and 6 µm transverse resolution) for endoscopic OCT imaging at 800 nm. Its performance and translational potential are demonstrated by in vivo imaging of a mouse colon, a rat esophagus, and small airways in sheep. |
format | Online Article Text |
id | pubmed-5688175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-56881752017-11-17 Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm Yuan, Wu Brown, Robert Mitzner, Wayne Yarmus, Lonny Li, Xingde Nat Commun Article Endoscopic optical coherence tomography (OCT) has emerged as a valuable tool for advancing our understanding of the histomorphology of various internal luminal organs and studying the pathogenesis of relevant diseases. To date, this technology affords limited resolving power for discerning subtle pathological changes associated with early diseases. In addition, it remains challenging to access small luminal organs or pass through narrow luminal sections without potentially causing trauma to tissue with a traditional OCT endoscope of a 1-1.5 mm diameter. Here we report an ultracompact (520 µm in outer diameter and 5 mm in rigid length) and super-achromatic microprobe made with a built-in monolithic fiber-optic ball lens, which achieves ultrahigh-resolution (1.7 µm axial resolution in tissue and 6 µm transverse resolution) for endoscopic OCT imaging at 800 nm. Its performance and translational potential are demonstrated by in vivo imaging of a mouse colon, a rat esophagus, and small airways in sheep. Nature Publishing Group UK 2017-11-16 /pmc/articles/PMC5688175/ /pubmed/29142274 http://dx.doi.org/10.1038/s41467-017-01494-4 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Yuan, Wu Brown, Robert Mitzner, Wayne Yarmus, Lonny Li, Xingde Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title | Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title_full | Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title_fullStr | Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title_full_unstemmed | Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title_short | Super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
title_sort | super-achromatic monolithic microprobe for ultrahigh-resolution endoscopic optical coherence tomography at 800 nm |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5688175/ https://www.ncbi.nlm.nih.gov/pubmed/29142274 http://dx.doi.org/10.1038/s41467-017-01494-4 |
work_keys_str_mv | AT yuanwu superachromaticmonolithicmicroprobeforultrahighresolutionendoscopicopticalcoherencetomographyat800nm AT brownrobert superachromaticmonolithicmicroprobeforultrahighresolutionendoscopicopticalcoherencetomographyat800nm AT mitznerwayne superachromaticmonolithicmicroprobeforultrahighresolutionendoscopicopticalcoherencetomographyat800nm AT yarmuslonny superachromaticmonolithicmicroprobeforultrahighresolutionendoscopicopticalcoherencetomographyat800nm AT lixingde superachromaticmonolithicmicroprobeforultrahighresolutionendoscopicopticalcoherencetomographyat800nm |