Cargando…
Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples
BACKGROUND: Dirofilaria immitis is a worldwide parasite that is endemic in many parts of the United States. There are many commercial assays available for the detection of D. immitis antigen, one of which was modified and has reentered the market. Our objective was to compare the recently reintroduc...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5688447/ https://www.ncbi.nlm.nih.gov/pubmed/29143666 http://dx.doi.org/10.1186/s13071-017-2447-3 |
_version_ | 1783279166866587648 |
---|---|
author | Starkey, Lindsay A. Bowles, Joy V. Payton, Mark E. Blagburn, Byron L. |
author_facet | Starkey, Lindsay A. Bowles, Joy V. Payton, Mark E. Blagburn, Byron L. |
author_sort | Starkey, Lindsay A. |
collection | PubMed |
description | BACKGROUND: Dirofilaria immitis is a worldwide parasite that is endemic in many parts of the United States. There are many commercial assays available for the detection of D. immitis antigen, one of which was modified and has reentered the market. Our objective was to compare the recently reintroduced Witness® Heartworm (HW) Antigen test Kit (Zoetis, Florham Park, NJ) and the SNAP® Heartworm RT (IDEXX Laboratories, Inc., Westbrook, ME) to the well-based ELISA DiroChek® Heartworm Antigen Test Kit (Zoetis, Florham Park, NJ). METHODS: Canine plasma samples were either received at the Auburn Diagnostic Parasitology Laboratory from veterinarians submitting samples for additional heartworm testing (n = 100) from 2008 to 2016 or purchased from purpose-bred beagles (n = 50, presumed negative) in 2016. Samples were categorized as “positive,” “borderline” or “negative” using our established spectrophotometric cutoff value with the DiroChek® assay when a sample was initially received and processed. Three commercially available heartworm antigen tests (DiroChek®, Witness® HW, and SNAP® RT) were utilized for simultaneous testing of the 150 samples in random order as per their package insert with the addition of spectrophotometric optical density (OD) readings of the DiroChek® assay. Any samples yielding discordant test results between assays were further evaluated by heat treatment of plasma and retesting. Chi-square tests for the equality of proportions were utilized for statistical analyses. RESULTS: Concordant results occurred in 140/150 (93.3%) samples. Discrepant results occurred in 10/150 samples tested (6.6%): 9/10 occurring in the borderline heartworm (HW) category and 1/10 occurring in the negative HW category. The sensitivity and specificity of each test compared to the DiroChek® read by spectrophotometer was similar to what has been reported previously (Witness®: sensitivity 97.0% [94.1–99.4%], specificity 96.4% [95.5–100.0%]; SNAP® RT: sensitivity 90.9% [78.0–100.0%], specificity 98.8% [96.0–100.0%]). There were significant differences detected when comparing the sensitivities of the SNAP® RT and the Witness® HW to the DiroChek® among the 150 total samples (p = 0.003) and the 50 “borderline” samples (p = 0.001). CONCLUSIONS: In this study, the sensitivity of the Witness® HW was higher than the sensitivity of the SNAP® RT when compared with the DiroChek® test results prior to heat treatment of samples. |
format | Online Article Text |
id | pubmed-5688447 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-56884472017-11-22 Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples Starkey, Lindsay A. Bowles, Joy V. Payton, Mark E. Blagburn, Byron L. Parasit Vectors Research BACKGROUND: Dirofilaria immitis is a worldwide parasite that is endemic in many parts of the United States. There are many commercial assays available for the detection of D. immitis antigen, one of which was modified and has reentered the market. Our objective was to compare the recently reintroduced Witness® Heartworm (HW) Antigen test Kit (Zoetis, Florham Park, NJ) and the SNAP® Heartworm RT (IDEXX Laboratories, Inc., Westbrook, ME) to the well-based ELISA DiroChek® Heartworm Antigen Test Kit (Zoetis, Florham Park, NJ). METHODS: Canine plasma samples were either received at the Auburn Diagnostic Parasitology Laboratory from veterinarians submitting samples for additional heartworm testing (n = 100) from 2008 to 2016 or purchased from purpose-bred beagles (n = 50, presumed negative) in 2016. Samples were categorized as “positive,” “borderline” or “negative” using our established spectrophotometric cutoff value with the DiroChek® assay when a sample was initially received and processed. Three commercially available heartworm antigen tests (DiroChek®, Witness® HW, and SNAP® RT) were utilized for simultaneous testing of the 150 samples in random order as per their package insert with the addition of spectrophotometric optical density (OD) readings of the DiroChek® assay. Any samples yielding discordant test results between assays were further evaluated by heat treatment of plasma and retesting. Chi-square tests for the equality of proportions were utilized for statistical analyses. RESULTS: Concordant results occurred in 140/150 (93.3%) samples. Discrepant results occurred in 10/150 samples tested (6.6%): 9/10 occurring in the borderline heartworm (HW) category and 1/10 occurring in the negative HW category. The sensitivity and specificity of each test compared to the DiroChek® read by spectrophotometer was similar to what has been reported previously (Witness®: sensitivity 97.0% [94.1–99.4%], specificity 96.4% [95.5–100.0%]; SNAP® RT: sensitivity 90.9% [78.0–100.0%], specificity 98.8% [96.0–100.0%]). There were significant differences detected when comparing the sensitivities of the SNAP® RT and the Witness® HW to the DiroChek® among the 150 total samples (p = 0.003) and the 50 “borderline” samples (p = 0.001). CONCLUSIONS: In this study, the sensitivity of the Witness® HW was higher than the sensitivity of the SNAP® RT when compared with the DiroChek® test results prior to heat treatment of samples. BioMed Central 2017-11-09 /pmc/articles/PMC5688447/ /pubmed/29143666 http://dx.doi.org/10.1186/s13071-017-2447-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Starkey, Lindsay A. Bowles, Joy V. Payton, Mark E. Blagburn, Byron L. Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title | Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title_full | Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title_fullStr | Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title_full_unstemmed | Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title_short | Comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
title_sort | comparative evaluation of commercially available point-of-care heartworm antigen tests using well-characterized canine plasma samples |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5688447/ https://www.ncbi.nlm.nih.gov/pubmed/29143666 http://dx.doi.org/10.1186/s13071-017-2447-3 |
work_keys_str_mv | AT starkeylindsaya comparativeevaluationofcommerciallyavailablepointofcareheartwormantigentestsusingwellcharacterizedcanineplasmasamples AT bowlesjoyv comparativeevaluationofcommerciallyavailablepointofcareheartwormantigentestsusingwellcharacterizedcanineplasmasamples AT paytonmarke comparativeevaluationofcommerciallyavailablepointofcareheartwormantigentestsusingwellcharacterizedcanineplasmasamples AT blagburnbyronl comparativeevaluationofcommerciallyavailablepointofcareheartwormantigentestsusingwellcharacterizedcanineplasmasamples |