Cargando…

Comparison of Different Invasive Hemodynamic Measurements as a Prediction Tool for Mortality after Transcatheter Aortic Valve Replacement in Men: A Retrospective Observational Study

INTRODUCTION: Hemodynamic measurements can assess for paravalvular aortic regurgitation after transcatheter aortic valve replacement (TAVR). This study compared the utility of different invasive hemodynamic measures in providing prognostic information. METHODS: This retrospective observational study...

Descripción completa

Detalles Bibliográficos
Autores principales: Bavry, Anthony A., Aalaei-Andabili, Seyed H., Karimi, Ashkan, Park, Ki, Choi, Calvin Y., Manning, Eddie W., Beaver, Thomas M., Stinson, Wade W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5688972/
https://www.ncbi.nlm.nih.gov/pubmed/28667514
http://dx.doi.org/10.1007/s40119-017-0095-5
Descripción
Sumario:INTRODUCTION: Hemodynamic measurements can assess for paravalvular aortic regurgitation after transcatheter aortic valve replacement (TAVR). This study compared the utility of different invasive hemodynamic measures in providing prognostic information. METHODS: This retrospective observational study of TAVR patients at a Veterans Hospital assessed aortic regurgitation index, diastolic delta, pulse pressure, and heart rate adjusted diastolic delta obtained at valve implantation. The primary outcome was total mortality. RESULTS: Overall, 151 patients underwent TAVR. Immediately after implantation, mean aortic regurgitation index was 31 ± 8.6, mean diastolic delta was 38 ± 9.8 mmHg, mean pulse pressure was 67 ± 18 mmHg, and mean heart rate adjusted diastolic delta was 47 ± 14.3 mmHg/beats per minute. Two percent of patients had ≥ moderate paravalvular aortic regurgitation by postoperative transthoracic echocardiography. Total mortality was 15.2% at a mean follow-up of 12.7 ± 9.2 months. Aortic regurgitation index <25 vs. ≥25, diastolic delta <19 vs. ≥19 mmHg, and pulse pressure >60 vs. ≤60 mmHg were not associated with total mortality. However, total mortality was 50% for heart rate adjusted diastolic delta <25 mmHg/beats per minute vs. 12.6% for heart rate adjusted diastolic delta ≥25 mmHg/beats per minute (p = 0.017). In a multivariate Cox regression analysis, heart rate adjusted diastolic delta <25 mmHg/beats per minute vs. heart rate adjusted diastolic delta ≥25 mmHg/beats per minute was associated with total mortality (hazard ratio 9.4, 95% confidence interval 2.0–44, p = 0.004). CONCLUSIONS: Among a cohort of TAVR patients, the only invasive hemodynamic test independently associated with total mortality was heart rate adjusted diastolic delta.