Cargando…

Effect of beam profile measurement on arc therapy plan quality assurance: a case study

We present an example when profile measurement and modeling of an Elekta Agility multileaf collimator (MLC) had a large effect specifically on arc therapy plan quality assurance (QA) results using ArcCheck. ArcCheck absolute dose measurements of these plans were systematically lower than planned by...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Leonard H., Malajovich, Irina, Reyhan, Meral L., Xue, Jinyu, Park, Joo Han
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689840/
https://www.ncbi.nlm.nih.gov/pubmed/28370918
http://dx.doi.org/10.1002/acm2.12071
_version_ 1783279468747423744
author Kim, Leonard H.
Malajovich, Irina
Reyhan, Meral L.
Xue, Jinyu
Park, Joo Han
author_facet Kim, Leonard H.
Malajovich, Irina
Reyhan, Meral L.
Xue, Jinyu
Park, Joo Han
author_sort Kim, Leonard H.
collection PubMed
description We present an example when profile measurement and modeling of an Elekta Agility multileaf collimator (MLC) had a large effect specifically on arc therapy plan quality assurance (QA) results using ArcCheck. ArcCheck absolute dose measurements of these plans were systematically lower than planned by 3–10%. Failing QA results were seen even with unmodulated static and conformal arcs. Furthermore, the effect was found to be dependent on collimator angle, with worse results associated with near‐zero collimator angles. In contrast, step‐and‐shoot QA results were not affected. Changing the beam model to match steeper profile measurements obtained using a different measurement device resolved the problem. This case study demonstrates that conventional gamma index analysis can be sensitive to small profile modeling changes.
format Online
Article
Text
id pubmed-5689840
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56898402018-04-02 Effect of beam profile measurement on arc therapy plan quality assurance: a case study Kim, Leonard H. Malajovich, Irina Reyhan, Meral L. Xue, Jinyu Park, Joo Han J Appl Clin Med Phys Radiation Oncology Physics We present an example when profile measurement and modeling of an Elekta Agility multileaf collimator (MLC) had a large effect specifically on arc therapy plan quality assurance (QA) results using ArcCheck. ArcCheck absolute dose measurements of these plans were systematically lower than planned by 3–10%. Failing QA results were seen even with unmodulated static and conformal arcs. Furthermore, the effect was found to be dependent on collimator angle, with worse results associated with near‐zero collimator angles. In contrast, step‐and‐shoot QA results were not affected. Changing the beam model to match steeper profile measurements obtained using a different measurement device resolved the problem. This case study demonstrates that conventional gamma index analysis can be sensitive to small profile modeling changes. John Wiley and Sons Inc. 2017-03-29 /pmc/articles/PMC5689840/ /pubmed/28370918 http://dx.doi.org/10.1002/acm2.12071 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Kim, Leonard H.
Malajovich, Irina
Reyhan, Meral L.
Xue, Jinyu
Park, Joo Han
Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title_full Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title_fullStr Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title_full_unstemmed Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title_short Effect of beam profile measurement on arc therapy plan quality assurance: a case study
title_sort effect of beam profile measurement on arc therapy plan quality assurance: a case study
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689840/
https://www.ncbi.nlm.nih.gov/pubmed/28370918
http://dx.doi.org/10.1002/acm2.12071
work_keys_str_mv AT kimleonardh effectofbeamprofilemeasurementonarctherapyplanqualityassuranceacasestudy
AT malajovichirina effectofbeamprofilemeasurementonarctherapyplanqualityassuranceacasestudy
AT reyhanmerall effectofbeamprofilemeasurementonarctherapyplanqualityassuranceacasestudy
AT xuejinyu effectofbeamprofilemeasurementonarctherapyplanqualityassuranceacasestudy
AT parkjoohan effectofbeamprofilemeasurementonarctherapyplanqualityassuranceacasestudy