Cargando…
Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients
As the advantage of using complex volumetric‐modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689869/ https://www.ncbi.nlm.nih.gov/pubmed/28291936 http://dx.doi.org/10.1002/acm2.12003 |
_version_ | 1783279474957090816 |
---|---|
author | Deng, Xia Han, Ce Chen, Shan Xie, Congying Yi, Jinling Zhou, Yongqiang Zheng, Xiaomin Deng, Zhenxiang Jin, Xiance |
author_facet | Deng, Xia Han, Ce Chen, Shan Xie, Congying Yi, Jinling Zhou, Yongqiang Zheng, Xiaomin Deng, Zhenxiang Jin, Xiance |
author_sort | Deng, Xia |
collection | PubMed |
description | As the advantage of using complex volumetric‐modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and intensity‐modulated radiotherapy (IMRT) in the treatment of 15 postoperative cervical cancer patients. Four‐field CRT, seven‐field IMRT, and two‐arc VMAT plans were generated for each patient with identical objective functions to achieve clinically acceptable dose distribution. Target coverage and OAR sparing differences were investigated through dose‐volume histogram (DVH) analysis. Nondosimtric differences between IMRT and VMAT were also compared. Target coverage presented by V95% were 88.9% ± 3.8%, 99.9% ± 0.07%, and 99.9% ± 0.1% for CRT, IMRT, and VMAT, respectively. Significant differences on conformal index (CI) and conformal number (CN) were observed with CIs of 0.37 ± 0.07, 0.55 ± 0.04, 0.61 ± 0.04, and CNs of 0.33 ± 0.06, 0.55 ± 0.04, 0.60 ± 0.04 for CRT, IMRT, and VMAT, respectively. IMRT and VMAT decreased the dose to bladder and rectum significantly compared with CRT. No significant differences on the Dmean, V45, and V30 of small bowel were observed among CRT, IMRT, and VMAT. However, VMAT (10.4 ± 4.8 vs. 19.8 ± 11.0, P = 0.004) and IMRT (12.3 ± 5.0 vs. 19.8 ± 11.0, P = 0.02) decreased V40, increased the Dmax of small bowel and the irradiation dose to femoral heads compared with CRT. VMAT irradiated less dose to bladder, rectum, small bowel and larger volume of health tissue with a lower dose (V5 and V10) compared with IMRT, although the differences were not statistical significant. In conclusion, VMAT and IMRT showed significant dosimetric advantages both on target coverage and OAR sparing compared with CRT in the treatment of postoperative cervical cancer. However, no significant difference between IMRT and VMAT was observed except for slightly better dose conformity, slightly less MU, and significant shorter delivery time achieved for VMAT. |
format | Online Article Text |
id | pubmed-5689869 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56898692018-04-02 Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients Deng, Xia Han, Ce Chen, Shan Xie, Congying Yi, Jinling Zhou, Yongqiang Zheng, Xiaomin Deng, Zhenxiang Jin, Xiance J Appl Clin Med Phys Radiation Oncology Physics As the advantage of using complex volumetric‐modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and intensity‐modulated radiotherapy (IMRT) in the treatment of 15 postoperative cervical cancer patients. Four‐field CRT, seven‐field IMRT, and two‐arc VMAT plans were generated for each patient with identical objective functions to achieve clinically acceptable dose distribution. Target coverage and OAR sparing differences were investigated through dose‐volume histogram (DVH) analysis. Nondosimtric differences between IMRT and VMAT were also compared. Target coverage presented by V95% were 88.9% ± 3.8%, 99.9% ± 0.07%, and 99.9% ± 0.1% for CRT, IMRT, and VMAT, respectively. Significant differences on conformal index (CI) and conformal number (CN) were observed with CIs of 0.37 ± 0.07, 0.55 ± 0.04, 0.61 ± 0.04, and CNs of 0.33 ± 0.06, 0.55 ± 0.04, 0.60 ± 0.04 for CRT, IMRT, and VMAT, respectively. IMRT and VMAT decreased the dose to bladder and rectum significantly compared with CRT. No significant differences on the Dmean, V45, and V30 of small bowel were observed among CRT, IMRT, and VMAT. However, VMAT (10.4 ± 4.8 vs. 19.8 ± 11.0, P = 0.004) and IMRT (12.3 ± 5.0 vs. 19.8 ± 11.0, P = 0.02) decreased V40, increased the Dmax of small bowel and the irradiation dose to femoral heads compared with CRT. VMAT irradiated less dose to bladder, rectum, small bowel and larger volume of health tissue with a lower dose (V5 and V10) compared with IMRT, although the differences were not statistical significant. In conclusion, VMAT and IMRT showed significant dosimetric advantages both on target coverage and OAR sparing compared with CRT in the treatment of postoperative cervical cancer. However, no significant difference between IMRT and VMAT was observed except for slightly better dose conformity, slightly less MU, and significant shorter delivery time achieved for VMAT. John Wiley and Sons Inc. 2016-11-21 /pmc/articles/PMC5689869/ /pubmed/28291936 http://dx.doi.org/10.1002/acm2.12003 Text en © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Deng, Xia Han, Ce Chen, Shan Xie, Congying Yi, Jinling Zhou, Yongqiang Zheng, Xiaomin Deng, Zhenxiang Jin, Xiance Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title | Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title_full | Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title_fullStr | Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title_full_unstemmed | Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title_short | Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
title_sort | dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689869/ https://www.ncbi.nlm.nih.gov/pubmed/28291936 http://dx.doi.org/10.1002/acm2.12003 |
work_keys_str_mv | AT dengxia dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT hance dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT chenshan dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT xiecongying dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT yijinling dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT zhouyongqiang dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT zhengxiaomin dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT dengzhenxiang dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients AT jinxiance dosimetricbenefitsofintensitymodulatedradiotherapyandvolumetricmodulatedarctherapyinthetreatmentofpostoperativecervicalcancerpatients |