Cargando…

Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation

Accurate prostate delineation is essential to ensure proper target coverage and normal‐tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS‐based prostate contour into HDR treatment planning through TRUS‐CT deform...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Xiaofeng, Rossi, Peter J., Jani, Ashesh B., Mao, Hui, Zhou, Zhengyang, Curran, Walter J., Liu, Tian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689894/
https://www.ncbi.nlm.nih.gov/pubmed/28291925
http://dx.doi.org/10.1002/acm2.12040
_version_ 1783279480493572096
author Yang, Xiaofeng
Rossi, Peter J.
Jani, Ashesh B.
Mao, Hui
Zhou, Zhengyang
Curran, Walter J.
Liu, Tian
author_facet Yang, Xiaofeng
Rossi, Peter J.
Jani, Ashesh B.
Mao, Hui
Zhou, Zhengyang
Curran, Walter J.
Liu, Tian
author_sort Yang, Xiaofeng
collection PubMed
description Accurate prostate delineation is essential to ensure proper target coverage and normal‐tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS‐based prostate contour into HDR treatment planning through TRUS‐CT deformable registration (TCDR) to improve prostate contour accuracy. In a perspective study of 16 patients, we investigated the clinical feasibility as well as the performance of this TCDR‐based HDR approach. We compared the performance of the TCDR‐based approach with the conventional CT‐based HDR in terms of prostate contour accuracy using MRI as the gold standard. For all patients, the average Dice prostate volume overlap was 91.1 ± 2.3% between the TCDR‐based and the MRI‐defined prostate volumes. In a subset of eight patients, inter and intro‐observer reliability study was conducted among three experienced physicians (two radiation oncologists and one radiologist) for the TCDR‐based HDR approach. Overall, a 10 to 40% improvement in prostate volume accuracy can be achieved with the TCDR‐based approach as compared with the conventional CT‐based prostate volumes. The TCDR‐based prostate volumes match closely to the MRI‐defined prostate volumes for all 3 observers (mean volume difference: 0.5 ± 7.2%, 1.8 ± 7.2%, and 3.5 ± 5.1%); while CT‐based contours overestimated prostate volumes by 10.9 ± 28.7%, 13.7 ± 20.1%, and 44.7 ± 32.1%. This study has shown that the TCDR‐based HDR brachytherapy is clinically feasible and can significantly improve prostate contour accuracy over the conventional CT‐based prostate contour. We also demonstrated the reliability of the TCDR‐based prostate delineation. This TCDR‐based HDR approach has the potential to enable accurate dose planning and delivery, and potentially enhance prostate HDR treatment outcome.
format Online
Article
Text
id pubmed-5689894
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56898942018-04-02 Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation Yang, Xiaofeng Rossi, Peter J. Jani, Ashesh B. Mao, Hui Zhou, Zhengyang Curran, Walter J. Liu, Tian J Appl Clin Med Phys Radiation Oncology Physics Accurate prostate delineation is essential to ensure proper target coverage and normal‐tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS‐based prostate contour into HDR treatment planning through TRUS‐CT deformable registration (TCDR) to improve prostate contour accuracy. In a perspective study of 16 patients, we investigated the clinical feasibility as well as the performance of this TCDR‐based HDR approach. We compared the performance of the TCDR‐based approach with the conventional CT‐based HDR in terms of prostate contour accuracy using MRI as the gold standard. For all patients, the average Dice prostate volume overlap was 91.1 ± 2.3% between the TCDR‐based and the MRI‐defined prostate volumes. In a subset of eight patients, inter and intro‐observer reliability study was conducted among three experienced physicians (two radiation oncologists and one radiologist) for the TCDR‐based HDR approach. Overall, a 10 to 40% improvement in prostate volume accuracy can be achieved with the TCDR‐based approach as compared with the conventional CT‐based prostate volumes. The TCDR‐based prostate volumes match closely to the MRI‐defined prostate volumes for all 3 observers (mean volume difference: 0.5 ± 7.2%, 1.8 ± 7.2%, and 3.5 ± 5.1%); while CT‐based contours overestimated prostate volumes by 10.9 ± 28.7%, 13.7 ± 20.1%, and 44.7 ± 32.1%. This study has shown that the TCDR‐based HDR brachytherapy is clinically feasible and can significantly improve prostate contour accuracy over the conventional CT‐based prostate contour. We also demonstrated the reliability of the TCDR‐based prostate delineation. This TCDR‐based HDR approach has the potential to enable accurate dose planning and delivery, and potentially enhance prostate HDR treatment outcome. John Wiley and Sons Inc. 2017-01-19 /pmc/articles/PMC5689894/ /pubmed/28291925 http://dx.doi.org/10.1002/acm2.12040 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Yang, Xiaofeng
Rossi, Peter J.
Jani, Ashesh B.
Mao, Hui
Zhou, Zhengyang
Curran, Walter J.
Liu, Tian
Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title_full Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title_fullStr Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title_full_unstemmed Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title_short Improved prostate delineation in prostate HDR brachytherapy with TRUS‐CT deformable registration technology: A pilot study with MRI validation
title_sort improved prostate delineation in prostate hdr brachytherapy with trus‐ct deformable registration technology: a pilot study with mri validation
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689894/
https://www.ncbi.nlm.nih.gov/pubmed/28291925
http://dx.doi.org/10.1002/acm2.12040
work_keys_str_mv AT yangxiaofeng improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT rossipeterj improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT janiasheshb improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT maohui improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT zhouzhengyang improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT curranwalterj improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation
AT liutian improvedprostatedelineationinprostatehdrbrachytherapywithtrusctdeformableregistrationtechnologyapilotstudywithmrivalidation