Cargando…

Development and performance evaluation of a high‐speed multileaf collimator

Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiang, Ye, Peiqing, Zhang, Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689895/
https://www.ncbi.nlm.nih.gov/pubmed/28291930
http://dx.doi.org/10.1002/acm2.12026
_version_ 1783279480730550272
author Zhang, Xiang
Ye, Peiqing
Zhang, Hui
author_facet Zhang, Xiang
Ye, Peiqing
Zhang, Hui
author_sort Zhang, Xiang
collection PubMed
description Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3–4 cm/s and a maximum leaf acceleration of 50–70 cm/s(2), which are inadequate to track fast target motion. To cope with this problem, we have recently developed a high‐speed multileaf collimator (HS‐MLC) prototype, which employs linear motors instead of rotary motors to drive leaves. Consequently, it inherits various benefits of linear motors, including direct drive and high dynamics. The primary aim of this paper was to introduce the development and performance evaluation of the HS‐MLC. The evaluation includes Monte Carlo simulations of the basic dosimetric properties, camera‐based measurements of the mechanical properties and tracking experiments for 25 sets of patient‐measured motion data. The Monte Carlo simulation results show that the maximum leakage at 6MV is 1.29% and the average is 0.61%. The end‐to‐end leakage is 3.96% for 5 cm offset and is 1.75% for 10 cm offset. The penumbra for a standard 10 × 10 cm(2) field ranges from 4.8 mm to 5.4 mm across the full range of leaf motion. The mechanical property measurements demonstrate that the maximum leaf speed is 40 cm/s, the maximum leaf acceleration is 1000 cm/s(2), and the geometric accuracy can be kept within 0.5 mm. Regarding the tracking experiments for a wide range of motion patterns (fast breathing, irregular breathing, etc.), a root‐mean‐square error (RMSE) of less than 0.19 mm was achieved. In conclusion, the HS‐MLC is able to well track fast target motion that is beyond the capability of conventional MLCs due to its superior mechanical properties. The new MLC design provides a feasible solution to make high‐accuracy and high‐efficiency motion management possible.
format Online
Article
Text
id pubmed-5689895
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56898952018-04-02 Development and performance evaluation of a high‐speed multileaf collimator Zhang, Xiang Ye, Peiqing Zhang, Hui J Appl Clin Med Phys Radiation Oncology Physics Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3–4 cm/s and a maximum leaf acceleration of 50–70 cm/s(2), which are inadequate to track fast target motion. To cope with this problem, we have recently developed a high‐speed multileaf collimator (HS‐MLC) prototype, which employs linear motors instead of rotary motors to drive leaves. Consequently, it inherits various benefits of linear motors, including direct drive and high dynamics. The primary aim of this paper was to introduce the development and performance evaluation of the HS‐MLC. The evaluation includes Monte Carlo simulations of the basic dosimetric properties, camera‐based measurements of the mechanical properties and tracking experiments for 25 sets of patient‐measured motion data. The Monte Carlo simulation results show that the maximum leakage at 6MV is 1.29% and the average is 0.61%. The end‐to‐end leakage is 3.96% for 5 cm offset and is 1.75% for 10 cm offset. The penumbra for a standard 10 × 10 cm(2) field ranges from 4.8 mm to 5.4 mm across the full range of leaf motion. The mechanical property measurements demonstrate that the maximum leaf speed is 40 cm/s, the maximum leaf acceleration is 1000 cm/s(2), and the geometric accuracy can be kept within 0.5 mm. Regarding the tracking experiments for a wide range of motion patterns (fast breathing, irregular breathing, etc.), a root‐mean‐square error (RMSE) of less than 0.19 mm was achieved. In conclusion, the HS‐MLC is able to well track fast target motion that is beyond the capability of conventional MLCs due to its superior mechanical properties. The new MLC design provides a feasible solution to make high‐accuracy and high‐efficiency motion management possible. John Wiley and Sons Inc. 2016-12-29 /pmc/articles/PMC5689895/ /pubmed/28291930 http://dx.doi.org/10.1002/acm2.12026 Text en © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Zhang, Xiang
Ye, Peiqing
Zhang, Hui
Development and performance evaluation of a high‐speed multileaf collimator
title Development and performance evaluation of a high‐speed multileaf collimator
title_full Development and performance evaluation of a high‐speed multileaf collimator
title_fullStr Development and performance evaluation of a high‐speed multileaf collimator
title_full_unstemmed Development and performance evaluation of a high‐speed multileaf collimator
title_short Development and performance evaluation of a high‐speed multileaf collimator
title_sort development and performance evaluation of a high‐speed multileaf collimator
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689895/
https://www.ncbi.nlm.nih.gov/pubmed/28291930
http://dx.doi.org/10.1002/acm2.12026
work_keys_str_mv AT zhangxiang developmentandperformanceevaluationofahighspeedmultileafcollimator
AT yepeiqing developmentandperformanceevaluationofahighspeedmultileafcollimator
AT zhanghui developmentandperformanceevaluationofahighspeedmultileafcollimator