Does gated beam delivery impact delivery accuracy on an Elekta linac?

In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. Delivery accuracy was examined with an emphasis on the impact of using short gating windows (low monitor unit beam‐on segments) or long beam hold times. The performance was assessed using a 20cm by...

Descripción completa

Detalles Bibliográficos
Autores principales: Jermoumi, Mohammed, Xie, Roger, Cao, Daliang, Housley, David J., Shepard, David M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689903/
https://www.ncbi.nlm.nih.gov/pubmed/28291908
http://dx.doi.org/10.1002/acm2.12020
_version_ 1783279482660978688
author Jermoumi, Mohammed
Xie, Roger
Cao, Daliang
Housley, David J.
Shepard, David M.
author_facet Jermoumi, Mohammed
Xie, Roger
Cao, Daliang
Housley, David J.
Shepard, David M.
author_sort Jermoumi, Mohammed
collection PubMed
description In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. Delivery accuracy was examined with an emphasis on the impact of using short gating windows (low monitor unit beam‐on segments) or long beam hold times. The performance was assessed using a 20cm by 20cm open field with the radiation delivered using a range of beam‐on and beam‐off time periods. Gated delivery measurements were also performed for two SBRT plans delivered using volumetric modulated arc therapy (VMAT). Tests included both free‐breathing based gating (covering a variety of gating windows) and simulated breath‐hold based gating. An IBA MatriXX 2D ion chamber array was used for data collection, and the gating accuracy at low MU was evaluated using gamma passing rates. For the 20 cm by 20 cm open field, the measurements generally showed close agreement between the gated and non‐gated beam deliveries. Discrepancies, however, began to appear with a 5‐to‐1 ratio of the beam‐off to beam‐on times. The discrepancies observed for these tight gating windows can be attributed to the small number of monitor units delivered during each beam‐on segment. Dose distribution analysis from the delivery of the two SBRT plans showed gamma passing rates (± 1%, 2%/1 mm) in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma passing rate of free‐breathing gating and breath‐hold gating deliveries were measured in the range of 95.7% to 100%. In conclusion, the results demonstrate that Elekta linacs can accurately deliver respiratory gated treatments for both free‐breathing and breath‐hold patients. Some caution should be exercised with the use of very tight gating windows.
format Online
Article
Text
id pubmed-5689903
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56899032018-04-02 Does gated beam delivery impact delivery accuracy on an Elekta linac? Jermoumi, Mohammed Xie, Roger Cao, Daliang Housley, David J. Shepard, David M. J Appl Clin Med Phys Radiation Oncology Physics In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. Delivery accuracy was examined with an emphasis on the impact of using short gating windows (low monitor unit beam‐on segments) or long beam hold times. The performance was assessed using a 20cm by 20cm open field with the radiation delivered using a range of beam‐on and beam‐off time periods. Gated delivery measurements were also performed for two SBRT plans delivered using volumetric modulated arc therapy (VMAT). Tests included both free‐breathing based gating (covering a variety of gating windows) and simulated breath‐hold based gating. An IBA MatriXX 2D ion chamber array was used for data collection, and the gating accuracy at low MU was evaluated using gamma passing rates. For the 20 cm by 20 cm open field, the measurements generally showed close agreement between the gated and non‐gated beam deliveries. Discrepancies, however, began to appear with a 5‐to‐1 ratio of the beam‐off to beam‐on times. The discrepancies observed for these tight gating windows can be attributed to the small number of monitor units delivered during each beam‐on segment. Dose distribution analysis from the delivery of the two SBRT plans showed gamma passing rates (± 1%, 2%/1 mm) in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma passing rate of free‐breathing gating and breath‐hold gating deliveries were measured in the range of 95.7% to 100%. In conclusion, the results demonstrate that Elekta linacs can accurately deliver respiratory gated treatments for both free‐breathing and breath‐hold patients. Some caution should be exercised with the use of very tight gating windows. John Wiley and Sons Inc. 2017-01-03 /pmc/articles/PMC5689903/ /pubmed/28291908 http://dx.doi.org/10.1002/acm2.12020 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Jermoumi, Mohammed
Xie, Roger
Cao, Daliang
Housley, David J.
Shepard, David M.
Does gated beam delivery impact delivery accuracy on an Elekta linac?
title Does gated beam delivery impact delivery accuracy on an Elekta linac?
title_full Does gated beam delivery impact delivery accuracy on an Elekta linac?
title_fullStr Does gated beam delivery impact delivery accuracy on an Elekta linac?
title_full_unstemmed Does gated beam delivery impact delivery accuracy on an Elekta linac?
title_short Does gated beam delivery impact delivery accuracy on an Elekta linac?
title_sort does gated beam delivery impact delivery accuracy on an elekta linac?
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689903/
https://www.ncbi.nlm.nih.gov/pubmed/28291908
http://dx.doi.org/10.1002/acm2.12020
work_keys_str_mv AT jermoumimohammed doesgatedbeamdeliveryimpactdeliveryaccuracyonanelektalinac
AT xieroger doesgatedbeamdeliveryimpactdeliveryaccuracyonanelektalinac
AT caodaliang doesgatedbeamdeliveryimpactdeliveryaccuracyonanelektalinac
AT housleydavidj doesgatedbeamdeliveryimpactdeliveryaccuracyonanelektalinac
AT sheparddavidm doesgatedbeamdeliveryimpactdeliveryaccuracyonanelektalinac