Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms

Site‐specific investigations of the role of radiomics in cancer diagnosis and therapy are emerging. We evaluated the reproducibility of radiomic features extracted from (18)Flourine–fluorodeoxyglucose ((18)F‐FDG) PET images for three parameters: manual versus computer‐aided segmentation methods, gra...

Descripción completa

Detalles Bibliográficos
Autores principales: Altazi, Baderaldeen A., Zhang, Geoffrey G., Fernandez, Daniel C., Montejo, Michael E., Hunt, Dylan, Werner, Joan, Biagioli, Matthew C., Moros, Eduardo G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689938/
https://www.ncbi.nlm.nih.gov/pubmed/28891217
http://dx.doi.org/10.1002/acm2.12170
_version_ 1783279491276079104
author Altazi, Baderaldeen A.
Zhang, Geoffrey G.
Fernandez, Daniel C.
Montejo, Michael E.
Hunt, Dylan
Werner, Joan
Biagioli, Matthew C.
Moros, Eduardo G.
author_facet Altazi, Baderaldeen A.
Zhang, Geoffrey G.
Fernandez, Daniel C.
Montejo, Michael E.
Hunt, Dylan
Werner, Joan
Biagioli, Matthew C.
Moros, Eduardo G.
author_sort Altazi, Baderaldeen A.
collection PubMed
description Site‐specific investigations of the role of radiomics in cancer diagnosis and therapy are emerging. We evaluated the reproducibility of radiomic features extracted from (18)Flourine–fluorodeoxyglucose ((18)F‐FDG) PET images for three parameters: manual versus computer‐aided segmentation methods, gray‐level discretization, and PET image reconstruction algorithms. Our cohort consisted of pretreatment PET/CT scans from 88 cervical cancer patients. Two board‐certified radiation oncologists manually segmented the metabolic tumor volume (MTV(1) and MTV(2)) for each patient. For comparison, we used a graphical‐based method to generate semiautomated segmented volumes (GBSV). To address any perturbations in radiomic feature values, we down‐sampled the tumor volumes into three gray‐levels: 32, 64, and 128 from the original gray‐level of 256. Finally, we analyzed the effect on radiomic features on PET images of eight patients due to four PET 3D‐reconstruction algorithms: maximum likelihood‐ordered subset expectation maximization (OSEM) iterative reconstruction (IR) method, fourier rebinning‐ML‐OSEM (FOREIR), FORE‐filtered back projection (FOREFBP), and 3D‐Reprojection (3DRP) analytical method. We extracted 79 features from all segmentation method, gray‐levels of down‐sampled volumes, and PET reconstruction algorithms. The features were extracted using gray‐level co‐occurrence matrices (GLCM), gray‐level size zone matrices (GLSZM), gray‐level run‐length matrices (GLRLM), neighborhood gray‐tone difference matrices (NGTDM), shape‐based features (SF), and intensity histogram features (IHF). We computed the Dice coefficient between each MTV and GBSV to measure segmentation accuracy. Coefficient values close to one indicate high agreement, and values close to zero indicate low agreement. We evaluated the effect on radiomic features by calculating the mean percentage differences ([Formula: see text]) between feature values measured from each pair of parameter elements (i.e. segmentation methods: MTV(1)‐MTV(2), MTV(1)‐GBSV, MTV(2)‐GBSV; gray‐levels: 64‐32, 64‐128, and 64‐256; reconstruction algorithms: OSEM‐FORE‐OSEM, OSEM‐FOREFBP, and OSEM‐3DRP). We used [Formula: see text] as a measure of radiomic feature reproducibility level, where any feature scored [Formula: see text] ±SD ≤ |25|% ± 35% was considered reproducible. We used Bland–Altman analysis to evaluate the mean, standard deviation (SD), and upper/lower reproducibility limits (U/LRL) for radiomic features in response to variation in each testing parameter. Furthermore, we proposed U/LRL as a method to classify the level of reproducibility: High— ±1% ≤ U/LRL ≤ ±30%; Intermediate— ±30% < U/LRL ≤ ±45%; Low— ±45 < U/LRL ≤ ±50%. We considered any feature below the low level as nonreproducible (NR). Finally, we calculated the interclass correlation coefficient (ICC) to evaluate the reliability of radiomic feature measurements for each parameter. The segmented volumes of 65 patients (81.3%) scored Dice coefficient >0.75 for all three volumes. The result outcomes revealed a tendency of higher radiomic feature reproducibility among segmentation pair MTV(1)‐GBSV than MTV(2)‐GBSV, gray‐level pairs of 64‐32 and 64‐128 than 64‐256, and reconstruction algorithm pairs of OSEM‐FOREIR and OSEM‐FOREFBP than OSEM‐3DRP. Although the choice of cervical tumor segmentation method, gray‐level value, and reconstruction algorithm may affect radiomic features, some features were characterized by high reproducibility through all testing parameters. The number of radiomic features that showed insensitivity to variations in segmentation methods, gray‐level discretization, and reconstruction algorithms was 10 (13%), 4 (5%), and 1 (1%), respectively. These results suggest that a careful analysis of the effects of these parameters is essential prior to any radiomics clinical application.
format Online
Article
Text
id pubmed-5689938
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56899382018-04-02 Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms Altazi, Baderaldeen A. Zhang, Geoffrey G. Fernandez, Daniel C. Montejo, Michael E. Hunt, Dylan Werner, Joan Biagioli, Matthew C. Moros, Eduardo G. J Appl Clin Med Phys Radiation Oncology Physics Site‐specific investigations of the role of radiomics in cancer diagnosis and therapy are emerging. We evaluated the reproducibility of radiomic features extracted from (18)Flourine–fluorodeoxyglucose ((18)F‐FDG) PET images for three parameters: manual versus computer‐aided segmentation methods, gray‐level discretization, and PET image reconstruction algorithms. Our cohort consisted of pretreatment PET/CT scans from 88 cervical cancer patients. Two board‐certified radiation oncologists manually segmented the metabolic tumor volume (MTV(1) and MTV(2)) for each patient. For comparison, we used a graphical‐based method to generate semiautomated segmented volumes (GBSV). To address any perturbations in radiomic feature values, we down‐sampled the tumor volumes into three gray‐levels: 32, 64, and 128 from the original gray‐level of 256. Finally, we analyzed the effect on radiomic features on PET images of eight patients due to four PET 3D‐reconstruction algorithms: maximum likelihood‐ordered subset expectation maximization (OSEM) iterative reconstruction (IR) method, fourier rebinning‐ML‐OSEM (FOREIR), FORE‐filtered back projection (FOREFBP), and 3D‐Reprojection (3DRP) analytical method. We extracted 79 features from all segmentation method, gray‐levels of down‐sampled volumes, and PET reconstruction algorithms. The features were extracted using gray‐level co‐occurrence matrices (GLCM), gray‐level size zone matrices (GLSZM), gray‐level run‐length matrices (GLRLM), neighborhood gray‐tone difference matrices (NGTDM), shape‐based features (SF), and intensity histogram features (IHF). We computed the Dice coefficient between each MTV and GBSV to measure segmentation accuracy. Coefficient values close to one indicate high agreement, and values close to zero indicate low agreement. We evaluated the effect on radiomic features by calculating the mean percentage differences ([Formula: see text]) between feature values measured from each pair of parameter elements (i.e. segmentation methods: MTV(1)‐MTV(2), MTV(1)‐GBSV, MTV(2)‐GBSV; gray‐levels: 64‐32, 64‐128, and 64‐256; reconstruction algorithms: OSEM‐FORE‐OSEM, OSEM‐FOREFBP, and OSEM‐3DRP). We used [Formula: see text] as a measure of radiomic feature reproducibility level, where any feature scored [Formula: see text] ±SD ≤ |25|% ± 35% was considered reproducible. We used Bland–Altman analysis to evaluate the mean, standard deviation (SD), and upper/lower reproducibility limits (U/LRL) for radiomic features in response to variation in each testing parameter. Furthermore, we proposed U/LRL as a method to classify the level of reproducibility: High— ±1% ≤ U/LRL ≤ ±30%; Intermediate— ±30% < U/LRL ≤ ±45%; Low— ±45 < U/LRL ≤ ±50%. We considered any feature below the low level as nonreproducible (NR). Finally, we calculated the interclass correlation coefficient (ICC) to evaluate the reliability of radiomic feature measurements for each parameter. The segmented volumes of 65 patients (81.3%) scored Dice coefficient >0.75 for all three volumes. The result outcomes revealed a tendency of higher radiomic feature reproducibility among segmentation pair MTV(1)‐GBSV than MTV(2)‐GBSV, gray‐level pairs of 64‐32 and 64‐128 than 64‐256, and reconstruction algorithm pairs of OSEM‐FOREIR and OSEM‐FOREFBP than OSEM‐3DRP. Although the choice of cervical tumor segmentation method, gray‐level value, and reconstruction algorithm may affect radiomic features, some features were characterized by high reproducibility through all testing parameters. The number of radiomic features that showed insensitivity to variations in segmentation methods, gray‐level discretization, and reconstruction algorithms was 10 (13%), 4 (5%), and 1 (1%), respectively. These results suggest that a careful analysis of the effects of these parameters is essential prior to any radiomics clinical application. John Wiley and Sons Inc. 2017-09-11 /pmc/articles/PMC5689938/ /pubmed/28891217 http://dx.doi.org/10.1002/acm2.12170 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Altazi, Baderaldeen A.
Zhang, Geoffrey G.
Fernandez, Daniel C.
Montejo, Michael E.
Hunt, Dylan
Werner, Joan
Biagioli, Matthew C.
Moros, Eduardo G.
Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title_full Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title_fullStr Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title_full_unstemmed Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title_short Reproducibility of F18‐FDG PET radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
title_sort reproducibility of f18‐fdg pet radiomic features for different cervical tumor segmentation methods, gray‐level discretization, and reconstruction algorithms
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5689938/
https://www.ncbi.nlm.nih.gov/pubmed/28891217
http://dx.doi.org/10.1002/acm2.12170
work_keys_str_mv AT altazibaderaldeena reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT zhanggeoffreyg reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT fernandezdanielc reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT montejomichaele reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT huntdylan reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT wernerjoan reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT biagiolimatthewc reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms
AT moroseduardog reproducibilityoff18fdgpetradiomicfeaturesfordifferentcervicaltumorsegmentationmethodsgrayleveldiscretizationandreconstructionalgorithms