Evaluation of GMI and PMI diffeomorphic‐based demons algorithms for aligning PET and CT Images
Fusion of anatomic information in computed tomography (CT) and functional information in [Formula: see text] positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and C...
Autores principales: | Yang, Juan, Wang, Hongjun, Zhang, You, Yin, Yong |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690013/ https://www.ncbi.nlm.nih.gov/pubmed/26218993 http://dx.doi.org/10.1120/jacmp.v16i4.5148 |