Cargando…
An energy minimization method for the correction of cupping artifacts in cone‐beam CT
The purpose of this study was to reduce cupping artifacts and improve quantitative accuracy of the images in cone‐beam CT (CBCT). An energy minimization method (EMM) is proposed to reduce cupping artifacts in reconstructed image of the CBCT. The cupping artifacts are iteratively optimized by using e...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690028/ https://www.ncbi.nlm.nih.gov/pubmed/27455478 http://dx.doi.org/10.1120/jacmp.v17i4.6023 |
_version_ | 1783279513062342656 |
---|---|
author | Xie, Shipeng Zhuang, Wenqin Li, Haibo |
author_facet | Xie, Shipeng Zhuang, Wenqin Li, Haibo |
author_sort | Xie, Shipeng |
collection | PubMed |
description | The purpose of this study was to reduce cupping artifacts and improve quantitative accuracy of the images in cone‐beam CT (CBCT). An energy minimization method (EMM) is proposed to reduce cupping artifacts in reconstructed image of the CBCT. The cupping artifacts are iteratively optimized by using efficient matrix computations, which are verified to be numerically stable by matrix analysis. Moreover, the energy in our formulation is convex in each of its variables, which brings the robustness of the proposed energy minimization algorithm. The cupping artifacts are estimated as a result of minimizing this energy. The results indicate that proposed algorithm is effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. The proposed method focuses on the reconstructed image without requiring any additional physical equipment; it is easily implemented and provides cupping correction using a single scan acquisition. The experimental results demonstrate that this method can successfully reduce the magnitude of cupping artifacts. The correction algorithm reported here may improve the uniformity of the reconstructed images, thus assisting the development of perfect volume visualization and threshold‐based visualization techniques for reconstructed images. PACS number(s): 87.57.cp |
format | Online Article Text |
id | pubmed-5690028 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56900282018-04-02 An energy minimization method for the correction of cupping artifacts in cone‐beam CT Xie, Shipeng Zhuang, Wenqin Li, Haibo J Appl Clin Med Phys Medical Imaging The purpose of this study was to reduce cupping artifacts and improve quantitative accuracy of the images in cone‐beam CT (CBCT). An energy minimization method (EMM) is proposed to reduce cupping artifacts in reconstructed image of the CBCT. The cupping artifacts are iteratively optimized by using efficient matrix computations, which are verified to be numerically stable by matrix analysis. Moreover, the energy in our formulation is convex in each of its variables, which brings the robustness of the proposed energy minimization algorithm. The cupping artifacts are estimated as a result of minimizing this energy. The results indicate that proposed algorithm is effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. The proposed method focuses on the reconstructed image without requiring any additional physical equipment; it is easily implemented and provides cupping correction using a single scan acquisition. The experimental results demonstrate that this method can successfully reduce the magnitude of cupping artifacts. The correction algorithm reported here may improve the uniformity of the reconstructed images, thus assisting the development of perfect volume visualization and threshold‐based visualization techniques for reconstructed images. PACS number(s): 87.57.cp John Wiley and Sons Inc. 2016-07-08 /pmc/articles/PMC5690028/ /pubmed/27455478 http://dx.doi.org/10.1120/jacmp.v17i4.6023 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Xie, Shipeng Zhuang, Wenqin Li, Haibo An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title | An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title_full | An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title_fullStr | An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title_full_unstemmed | An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title_short | An energy minimization method for the correction of cupping artifacts in cone‐beam CT |
title_sort | energy minimization method for the correction of cupping artifacts in cone‐beam ct |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690028/ https://www.ncbi.nlm.nih.gov/pubmed/27455478 http://dx.doi.org/10.1120/jacmp.v17i4.6023 |
work_keys_str_mv | AT xieshipeng anenergyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct AT zhuangwenqin anenergyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct AT lihaibo anenergyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct AT xieshipeng energyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct AT zhuangwenqin energyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct AT lihaibo energyminimizationmethodforthecorrectionofcuppingartifactsinconebeamct |