Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy
In lung stereotactic body radiotherapy (SBRT) cases, the pencil beam (PB) dose calculation algorithm is known to overestimate target dose as compared to the more accurate Monte Carlo (MC) algorithm. We investigated whether changing the normalized prescription isodose line affected the magnitude of M...
Autores principales: | Zheng, Dandan, Zhang, Qinghui, Liang, Xiaoying, Zhu, Xiaofeng, Verma, Vivek, Wang, Shuo, Zhou, Sumin |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690053/ https://www.ncbi.nlm.nih.gov/pubmed/27455476 http://dx.doi.org/10.1120/jacmp.v17i4.5965 |
Ejemplares similares
-
Target dose conversion modeling from pencil beam (PB) to Monte Carlo (MC) for lung SBRT
por: Zheng, Dandan, et al.
Publicado: (2016) -
Monte Carlo vs. Pencil Beam based optimization of stereotactic lung IMRT
por: Sikora, Marcin, et al.
Publicado: (2009) -
A comprehensive dosimetric study of Monte Carlo and pencil‐beam algorithms on intensity‐modulated proton therapy for breast cancer
por: Liang, Xiaoying, et al.
Publicado: (2018) -
Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy
por: Zhuang, Tingliang, et al.
Publicado: (2013) -
Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy
por: Elcim, Yelda, et al.
Publicado: (2018)