Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback
We assessed interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography at end‐exhalation (EE) with visual feedback (BH‐CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity‐modulated radiation therapy with visual feedb...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690071/ https://www.ncbi.nlm.nih.gov/pubmed/26103180 http://dx.doi.org/10.1120/jacmp.v16i2.5123 |
_version_ | 1783279522960900096 |
---|---|
author | Nakamura, Mitsuhiro Akimoto, Mami Ono, Tomohiro Nakamura, Akira Kishi, Takahiro Yano, Shinsuke Nakata, Manabu Itasaka, Satoshi Mizowaki, Takashi Shibuya, Keiko Hiraoka, Masahiro |
author_facet | Nakamura, Mitsuhiro Akimoto, Mami Ono, Tomohiro Nakamura, Akira Kishi, Takahiro Yano, Shinsuke Nakata, Manabu Itasaka, Satoshi Mizowaki, Takashi Shibuya, Keiko Hiraoka, Masahiro |
author_sort | Nakamura, Mitsuhiro |
collection | PubMed |
description | We assessed interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography at end‐exhalation (EE) with visual feedback (BH‐CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity‐modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for [Formula: see text] before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH‐CBCT scans were performed before beam delivery in every fraction. BH‐CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interruptions variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions, respectively. Absolute interfraction variations of [Formula: see text] were observed in 18 fractions (11.0%) from seven patients because of EE‐BH failure. In conclusion, target matching is required to correct interfraction variation even with visual feedback, especially to ensure safe delivery of escalated doses to patients with pancreatic cancer. PACS number: 87.57.Q‐, 87.57.‐s, 87.55.Qr |
format | Online Article Text |
id | pubmed-5690071 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56900712018-04-02 Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback Nakamura, Mitsuhiro Akimoto, Mami Ono, Tomohiro Nakamura, Akira Kishi, Takahiro Yano, Shinsuke Nakata, Manabu Itasaka, Satoshi Mizowaki, Takashi Shibuya, Keiko Hiraoka, Masahiro J Appl Clin Med Phys Radiation Oncology Physics We assessed interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography at end‐exhalation (EE) with visual feedback (BH‐CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity‐modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for [Formula: see text] before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH‐CBCT scans were performed before beam delivery in every fraction. BH‐CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interruptions variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left–right (LR), anterior–posterior (AP), and superior–inferior (SI) directions, respectively. Absolute interfraction variations of [Formula: see text] were observed in 18 fractions (11.0%) from seven patients because of EE‐BH failure. In conclusion, target matching is required to correct interfraction variation even with visual feedback, especially to ensure safe delivery of escalated doses to patients with pancreatic cancer. PACS number: 87.57.Q‐, 87.57.‐s, 87.55.Qr John Wiley and Sons Inc. 2015-03-08 /pmc/articles/PMC5690071/ /pubmed/26103180 http://dx.doi.org/10.1120/jacmp.v16i2.5123 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Nakamura, Mitsuhiro Akimoto, Mami Ono, Tomohiro Nakamura, Akira Kishi, Takahiro Yano, Shinsuke Nakata, Manabu Itasaka, Satoshi Mizowaki, Takashi Shibuya, Keiko Hiraoka, Masahiro Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title | Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title_full | Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title_fullStr | Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title_full_unstemmed | Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title_short | Interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
title_sort | interfraction positional variation in pancreatic tumors using daily breath‐hold cone‐beam computed tomography with visual feedback |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690071/ https://www.ncbi.nlm.nih.gov/pubmed/26103180 http://dx.doi.org/10.1120/jacmp.v16i2.5123 |
work_keys_str_mv | AT nakamuramitsuhiro interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT akimotomami interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT onotomohiro interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT nakamuraakira interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT kishitakahiro interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT yanoshinsuke interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT nakatamanabu interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT itasakasatoshi interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT mizowakitakashi interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT shibuyakeiko interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback AT hiraokamasahiro interfractionpositionalvariationinpancreatictumorsusingdailybreathholdconebeamcomputedtomographywithvisualfeedback |