Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing

Respiratory monitoring systems are required to supply CT scanners with information on the patient's breathing during the acquisition of a respiration‐correlated computer tomography (RCCT), also referred to as 4D CT. The information a respiratory monitoring system has to provide to the CT scanne...

Descripción completa

Detalles Bibliográficos
Autores principales: Heinz, Christian, Reiner, Michael, Belka, Claus, Walter, Franziska, Söhn, Matthias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690076/
https://www.ncbi.nlm.nih.gov/pubmed/26103168
http://dx.doi.org/10.1120/jacmp.v16i2.4917
_version_ 1783279524114333696
author Heinz, Christian
Reiner, Michael
Belka, Claus
Walter, Franziska
Söhn, Matthias
author_facet Heinz, Christian
Reiner, Michael
Belka, Claus
Walter, Franziska
Söhn, Matthias
author_sort Heinz, Christian
collection PubMed
description Respiratory monitoring systems are required to supply CT scanners with information on the patient's breathing during the acquisition of a respiration‐correlated computer tomography (RCCT), also referred to as 4D CT. The information a respiratory monitoring system has to provide to the CT scanner depends on the specific scanner. The purpose of this study is to compare two different respiratory monitoring systems (Anzai Respiratory Gating System; C‐RAD Sentinel) with respect to their applicability in combination with an Aquilion Large Bore CT scanner from Toshiba. The scanner used in our clinic does not make use of the full time dependent breathing signal, but only single trigger pulses indicating the beginning of a new breathing cycle. Hence the attached respiratory monitoring system is expected to deliver accurate online trigger pulse for each breathing cycle. The accuracy of the trigger pulses sent to the CT scanner has to be ensured by the selected respiratory monitoring system. Since a trigger pulse (output signal) of a respiratory monitoring system is a function of the measured breathing signal (input signal), the typical clinical range of the input signal is estimated for both examined respiratory monitoring systems. Both systems are analyzed based on the following parameters: time resolution, signal amplitude, noise, signal‐to‐noise ratio (SNR), signal linearity, trigger compatibility, and clinical examples. The Anzai system shows a better SNR ([Formula: see text]) than the Sentinel system ([Formula: see text]). In terms of compatibility with the cycle‐based image sorting algorithm of the Toshiba CT scanner, the Anzai system benefits from the possibility to generate cycle‐based triggers, whereas the Sentinel system is only able to generate amplitude‐based triggers. In clinical practice, the combination of a Toshiba CT scanner and the Anzai system will provide better results due to the compatibility of the image sorting and trigger release methods. PACS numbers: 87.57.Q‐, 07.07.Df
format Online
Article
Text
id pubmed-5690076
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56900762018-04-02 Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing Heinz, Christian Reiner, Michael Belka, Claus Walter, Franziska Söhn, Matthias J Appl Clin Med Phys Medical Imaging Respiratory monitoring systems are required to supply CT scanners with information on the patient's breathing during the acquisition of a respiration‐correlated computer tomography (RCCT), also referred to as 4D CT. The information a respiratory monitoring system has to provide to the CT scanner depends on the specific scanner. The purpose of this study is to compare two different respiratory monitoring systems (Anzai Respiratory Gating System; C‐RAD Sentinel) with respect to their applicability in combination with an Aquilion Large Bore CT scanner from Toshiba. The scanner used in our clinic does not make use of the full time dependent breathing signal, but only single trigger pulses indicating the beginning of a new breathing cycle. Hence the attached respiratory monitoring system is expected to deliver accurate online trigger pulse for each breathing cycle. The accuracy of the trigger pulses sent to the CT scanner has to be ensured by the selected respiratory monitoring system. Since a trigger pulse (output signal) of a respiratory monitoring system is a function of the measured breathing signal (input signal), the typical clinical range of the input signal is estimated for both examined respiratory monitoring systems. Both systems are analyzed based on the following parameters: time resolution, signal amplitude, noise, signal‐to‐noise ratio (SNR), signal linearity, trigger compatibility, and clinical examples. The Anzai system shows a better SNR ([Formula: see text]) than the Sentinel system ([Formula: see text]). In terms of compatibility with the cycle‐based image sorting algorithm of the Toshiba CT scanner, the Anzai system benefits from the possibility to generate cycle‐based triggers, whereas the Sentinel system is only able to generate amplitude‐based triggers. In clinical practice, the combination of a Toshiba CT scanner and the Anzai system will provide better results due to the compatibility of the image sorting and trigger release methods. PACS numbers: 87.57.Q‐, 07.07.Df John Wiley and Sons Inc. 2015-03-08 /pmc/articles/PMC5690076/ /pubmed/26103168 http://dx.doi.org/10.1120/jacmp.v16i2.4917 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Heinz, Christian
Reiner, Michael
Belka, Claus
Walter, Franziska
Söhn, Matthias
Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title_full Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title_fullStr Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title_full_unstemmed Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title_short Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing
title_sort technical evaluation of different respiratory monitoring systems used for 4d ct acquisition under free breathing
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690076/
https://www.ncbi.nlm.nih.gov/pubmed/26103168
http://dx.doi.org/10.1120/jacmp.v16i2.4917
work_keys_str_mv AT heinzchristian technicalevaluationofdifferentrespiratorymonitoringsystemsusedfor4dctacquisitionunderfreebreathing
AT reinermichael technicalevaluationofdifferentrespiratorymonitoringsystemsusedfor4dctacquisitionunderfreebreathing
AT belkaclaus technicalevaluationofdifferentrespiratorymonitoringsystemsusedfor4dctacquisitionunderfreebreathing
AT walterfranziska technicalevaluationofdifferentrespiratorymonitoringsystemsusedfor4dctacquisitionunderfreebreathing
AT sohnmatthias technicalevaluationofdifferentrespiratorymonitoringsystemsusedfor4dctacquisitionunderfreebreathing