Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations

The assessment of intracranial aneurysms is increasingly performed using three‐dimensional cone‐beam rotational angiography (3D CBRA). To reduce the dose to the patient during 3D CBRA procedures, filtered region‐of‐interest imaging (FROI) is presented in literature to be an effective technique as th...

Descripción completa

Detalles Bibliográficos
Autores principales: Göpfert, Fabian, Schmidt, Ralph, Wulff, Jörg, Zink, Klemens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690097/
https://www.ncbi.nlm.nih.gov/pubmed/26103200
http://dx.doi.org/10.1120/jacmp.v16i2.5306
_version_ 1783279528890597376
author Göpfert, Fabian
Schmidt, Ralph
Wulff, Jörg
Zink, Klemens
author_facet Göpfert, Fabian
Schmidt, Ralph
Wulff, Jörg
Zink, Klemens
author_sort Göpfert, Fabian
collection PubMed
description The assessment of intracranial aneurysms is increasingly performed using three‐dimensional cone‐beam rotational angiography (3D CBRA). To reduce the dose to the patient during 3D CBRA procedures, filtered region‐of‐interest imaging (FROI) is presented in literature to be an effective technique as the dose in regions of low interest is reduced, while high image quality is preserved in the ROI. The purpose of this study was to quantify the benefit of FROI imaging during a typical 3D CBRA procedure in a patient's head region. A cone‐beam rotational angiography unit (Infinix) was modeled in GMctdospp, an EGSnrc‐based Monte Carlo software, which calculates patient dose distributions in rotational computed tomography. Kodak Lanex, a gadolinium compound, was chosen to be the ROI filter material. The adult female ICRP reference phantom was integrated in GMctdospp to calculate organ and effective doses in simulations of FROI‐CBRA examinations. During the Monte Carlo simulations, different parameters as the ROI filter thickness, the ROI opening size, the tube voltage, and the isocenter position were varied. The results showed that the reduction in dose clearly depends on these parameters. Comparing the reduction in organ dose in standard 3D CBRA and FROI‐CBRA, a maximum reduction of about 60%–80% could be achieved with a small sized ROI filter and about 40%–70% of the dose could be saved using a ROI filter with a large opening. Further we could show that dose reduction strongly depends on filter thickness, the location of the organ in the radiated area, and the position of the isocenter. As a consequence, dose reduction partially differs from theoretically calculated values by a factor up to 1.6. The effective dose could be reduced to a minimum of about 40%. Due to the fact that standard 3D CBRA is only used for the assessment of aneurysms at present and, thus, most of the patient dose originates from the aneurysm treatment (with 2D techniques) itself, the dose reduction effect of ROI filtering in 3D CBRA tends to be much smaller, if the patient dose of a whole aneurysm treatment procedure is considered. PACS numbers: 87.59.DJ, 87.55.kh
format Online
Article
Text
id pubmed-5690097
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56900972018-04-02 Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations Göpfert, Fabian Schmidt, Ralph Wulff, Jörg Zink, Klemens J Appl Clin Med Phys Medical Imaging The assessment of intracranial aneurysms is increasingly performed using three‐dimensional cone‐beam rotational angiography (3D CBRA). To reduce the dose to the patient during 3D CBRA procedures, filtered region‐of‐interest imaging (FROI) is presented in literature to be an effective technique as the dose in regions of low interest is reduced, while high image quality is preserved in the ROI. The purpose of this study was to quantify the benefit of FROI imaging during a typical 3D CBRA procedure in a patient's head region. A cone‐beam rotational angiography unit (Infinix) was modeled in GMctdospp, an EGSnrc‐based Monte Carlo software, which calculates patient dose distributions in rotational computed tomography. Kodak Lanex, a gadolinium compound, was chosen to be the ROI filter material. The adult female ICRP reference phantom was integrated in GMctdospp to calculate organ and effective doses in simulations of FROI‐CBRA examinations. During the Monte Carlo simulations, different parameters as the ROI filter thickness, the ROI opening size, the tube voltage, and the isocenter position were varied. The results showed that the reduction in dose clearly depends on these parameters. Comparing the reduction in organ dose in standard 3D CBRA and FROI‐CBRA, a maximum reduction of about 60%–80% could be achieved with a small sized ROI filter and about 40%–70% of the dose could be saved using a ROI filter with a large opening. Further we could show that dose reduction strongly depends on filter thickness, the location of the organ in the radiated area, and the position of the isocenter. As a consequence, dose reduction partially differs from theoretically calculated values by a factor up to 1.6. The effective dose could be reduced to a minimum of about 40%. Due to the fact that standard 3D CBRA is only used for the assessment of aneurysms at present and, thus, most of the patient dose originates from the aneurysm treatment (with 2D techniques) itself, the dose reduction effect of ROI filtering in 3D CBRA tends to be much smaller, if the patient dose of a whole aneurysm treatment procedure is considered. PACS numbers: 87.59.DJ, 87.55.kh John Wiley and Sons Inc. 2015-03-08 /pmc/articles/PMC5690097/ /pubmed/26103200 http://dx.doi.org/10.1120/jacmp.v16i2.5306 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Göpfert, Fabian
Schmidt, Ralph
Wulff, Jörg
Zink, Klemens
Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title_full Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title_fullStr Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title_full_unstemmed Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title_short Effect of ROI filtering in 3D cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
title_sort effect of roi filtering in 3d cone‐beam rotational angiography on organ dose and effective dose in cerebral investigations
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690097/
https://www.ncbi.nlm.nih.gov/pubmed/26103200
http://dx.doi.org/10.1120/jacmp.v16i2.5306
work_keys_str_mv AT gopfertfabian effectofroifilteringin3dconebeamrotationalangiographyonorgandoseandeffectivedoseincerebralinvestigations
AT schmidtralph effectofroifilteringin3dconebeamrotationalangiographyonorgandoseandeffectivedoseincerebralinvestigations
AT wulffjorg effectofroifilteringin3dconebeamrotationalangiographyonorgandoseandeffectivedoseincerebralinvestigations
AT zinkklemens effectofroifilteringin3dconebeamrotationalangiographyonorgandoseandeffectivedoseincerebralinvestigations