Cargando…

Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy

We present a quantitative methodology to measure head interfraction movements within intracranial masks of commercial immobilization devices used for proton radiotherapy. A three‐points tracking (3PtTrack) method was developed to measure the mask location for each treatment field over an average of...

Descripción completa

Detalles Bibliográficos
Autores principales: His, Wen C., Schreuder, Andries N., Zeidan, Omar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690173/
https://www.ncbi.nlm.nih.gov/pubmed/26699301
http://dx.doi.org/10.1120/jacmp.v16i5.5405
_version_ 1783279547651719168
author His, Wen C.
Schreuder, Andries N.
Zeidan, Omar
author_facet His, Wen C.
Schreuder, Andries N.
Zeidan, Omar
author_sort His, Wen C.
collection PubMed
description We present a quantitative methodology to measure head interfraction movements within intracranial masks of commercial immobilization devices used for proton radiotherapy. A three‐points tracking (3PtTrack) method was developed to measure the mask location for each treatment field over an average of 10 fractions for seven patients. Five patients were treated in supine with the Qfix Base‐of‐Skull (BoS) headframe, and two patients were treated in prone with the CIVCO Uni‐frame baseplate. Patients were first localized by an in‐room, image‐guidance (IG) system, and then the mask location was measured using the 3PtTrack method. Measured mask displacements from initial location at the first fraction are considered equivalent to the head interfraction movement within the mask. The trends of head movements and couch displacements and rotation were analyzed in three major directions. The accuracy of 3PtTrack method was shown to be within 1.0 mm based on daily measurements of a QA device after localization by the IG system for a period of three months. For seven patients, mean values of standard deviation (SD) in anterior–posterior, lateral, and superior–inferior directions were 1.1 mm, 1.4 mm, and 1.6 mm for head movements, and were 1.4 mm, 1.8 mm, and 3.4 mm for couch displacements. The mean SD values of couch rotations were 1.1°, 0.9°, and 1.1° for yaw, pitch, and roll, respectively. The overall patterns of head movements and couch displacements were similar for patients treated in either supine or prone, with larger deviations in the superior–inferior (SI) direction. A suboptimal mask fixation to the frame of the mask to the H&N frame is likely the cause for the observed larger head movements and couch displacements in the SI direction compared to other directions. The optical‐tracking methodology provided a quantitative assessment of the magnitude of head motion. PACS number: 87.55.km
format Online
Article
Text
id pubmed-5690173
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56901732018-04-02 Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy His, Wen C. Schreuder, Andries N. Zeidan, Omar J Appl Clin Med Phys Radiation Oncology Physics We present a quantitative methodology to measure head interfraction movements within intracranial masks of commercial immobilization devices used for proton radiotherapy. A three‐points tracking (3PtTrack) method was developed to measure the mask location for each treatment field over an average of 10 fractions for seven patients. Five patients were treated in supine with the Qfix Base‐of‐Skull (BoS) headframe, and two patients were treated in prone with the CIVCO Uni‐frame baseplate. Patients were first localized by an in‐room, image‐guidance (IG) system, and then the mask location was measured using the 3PtTrack method. Measured mask displacements from initial location at the first fraction are considered equivalent to the head interfraction movement within the mask. The trends of head movements and couch displacements and rotation were analyzed in three major directions. The accuracy of 3PtTrack method was shown to be within 1.0 mm based on daily measurements of a QA device after localization by the IG system for a period of three months. For seven patients, mean values of standard deviation (SD) in anterior–posterior, lateral, and superior–inferior directions were 1.1 mm, 1.4 mm, and 1.6 mm for head movements, and were 1.4 mm, 1.8 mm, and 3.4 mm for couch displacements. The mean SD values of couch rotations were 1.1°, 0.9°, and 1.1° for yaw, pitch, and roll, respectively. The overall patterns of head movements and couch displacements were similar for patients treated in either supine or prone, with larger deviations in the superior–inferior (SI) direction. A suboptimal mask fixation to the frame of the mask to the H&N frame is likely the cause for the observed larger head movements and couch displacements in the SI direction compared to other directions. The optical‐tracking methodology provided a quantitative assessment of the magnitude of head motion. PACS number: 87.55.km John Wiley and Sons Inc. 2015-09-08 /pmc/articles/PMC5690173/ /pubmed/26699301 http://dx.doi.org/10.1120/jacmp.v16i5.5405 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
His, Wen C.
Schreuder, Andries N.
Zeidan, Omar
Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title_full Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title_fullStr Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title_full_unstemmed Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title_short Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
title_sort utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690173/
https://www.ncbi.nlm.nih.gov/pubmed/26699301
http://dx.doi.org/10.1120/jacmp.v16i5.5405
work_keys_str_mv AT hiswenc utilizationofopticaltrackingtoassessefficacyofintracranialimmobilizationtechniquesinprotontherapy
AT schreuderandriesn utilizationofopticaltrackingtoassessefficacyofintracranialimmobilizationtechniquesinprotontherapy
AT zeidanomar utilizationofopticaltrackingtoassessefficacyofintracranialimmobilizationtechniquesinprotontherapy