Cargando…
A survey on table tolerances and couch overrides in radiotherapy
The purpose of this study was to survey current departmental policies on treatment couch overrides and the values of table tolerances used clinically. A 25‐question electronic survey on couch overrides and tolerances was sent to full members of the American Association of Physicists in Medicine (AAP...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690513/ https://www.ncbi.nlm.nih.gov/pubmed/27929512 http://dx.doi.org/10.1120/jacmp.v17i6.6261 |
_version_ | 1783279623979663360 |
---|---|
author | Chinsky, Bonnie Patel, Rakesh Panfil, Joshua Surucu, Murat Roeske, John C. |
author_facet | Chinsky, Bonnie Patel, Rakesh Panfil, Joshua Surucu, Murat Roeske, John C. |
author_sort | Chinsky, Bonnie |
collection | PubMed |
description | The purpose of this study was to survey current departmental policies on treatment couch overrides and the values of table tolerances used clinically. A 25‐question electronic survey on couch overrides and tolerances was sent to full members of the American Association of Physicists in Medicine (AAPM). The first part of the survey asked participants if table overrides were allowed at their institution, who was allowed to perform these overrides, and if imaging was required with overrides. The second part of the survey asked individuals to provide table tolerance data for the following treatment sites: brain/head and neck (H&N), lung, breast, abdomen/pelvis and prostate. Each site was further divided into IMRT/VMAT and 3D conformal techniques. Spaces for free‐text were provided, allowing respondents to enter any table tolerance data they were unable to specify under the treatment sites listed. A total of 361 individuals responded, of which approximately half participated in the couch tolerances portion of the survey. Overall, 86% of respondents’ institutions allow couch tolerance overrides at treatment. Therapists were the most common staff members permitted to perform overrides, followed by physicists, dosimetrists, and physicians, respectively. Of the institutions allowing overrides, 34% reported overriding daily. More than half of the centers document the override and/or require a setup image to radiographically verify the treatment site. With respect to table tolerances, SRS/SBRT table tolerances were the tightest, while clinical setup table tolerances were the largest. There were minimal statistically significant differences between IMRT/VMAT and 3D conformal table tolerances. Our results demonstrated that table overrides are relatively common in radiotherapy despite being a potential safety concern. Institutions should review their override policy and table tolerance values in light of the practices of other institutions. Careful attention to these matters is crucial in ensuring the safe and accurate delivery of radiotherapy. PACS number(s): 87.55.N‐, 87.55.Qr, 87.55.T‐ |
format | Online Article Text |
id | pubmed-5690513 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56905132018-04-02 A survey on table tolerances and couch overrides in radiotherapy Chinsky, Bonnie Patel, Rakesh Panfil, Joshua Surucu, Murat Roeske, John C. J Appl Clin Med Phys Management and Profession The purpose of this study was to survey current departmental policies on treatment couch overrides and the values of table tolerances used clinically. A 25‐question electronic survey on couch overrides and tolerances was sent to full members of the American Association of Physicists in Medicine (AAPM). The first part of the survey asked participants if table overrides were allowed at their institution, who was allowed to perform these overrides, and if imaging was required with overrides. The second part of the survey asked individuals to provide table tolerance data for the following treatment sites: brain/head and neck (H&N), lung, breast, abdomen/pelvis and prostate. Each site was further divided into IMRT/VMAT and 3D conformal techniques. Spaces for free‐text were provided, allowing respondents to enter any table tolerance data they were unable to specify under the treatment sites listed. A total of 361 individuals responded, of which approximately half participated in the couch tolerances portion of the survey. Overall, 86% of respondents’ institutions allow couch tolerance overrides at treatment. Therapists were the most common staff members permitted to perform overrides, followed by physicists, dosimetrists, and physicians, respectively. Of the institutions allowing overrides, 34% reported overriding daily. More than half of the centers document the override and/or require a setup image to radiographically verify the treatment site. With respect to table tolerances, SRS/SBRT table tolerances were the tightest, while clinical setup table tolerances were the largest. There were minimal statistically significant differences between IMRT/VMAT and 3D conformal table tolerances. Our results demonstrated that table overrides are relatively common in radiotherapy despite being a potential safety concern. Institutions should review their override policy and table tolerance values in light of the practices of other institutions. Careful attention to these matters is crucial in ensuring the safe and accurate delivery of radiotherapy. PACS number(s): 87.55.N‐, 87.55.Qr, 87.55.T‐ John Wiley and Sons Inc. 2016-11-08 /pmc/articles/PMC5690513/ /pubmed/27929512 http://dx.doi.org/10.1120/jacmp.v17i6.6261 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Management and Profession Chinsky, Bonnie Patel, Rakesh Panfil, Joshua Surucu, Murat Roeske, John C. A survey on table tolerances and couch overrides in radiotherapy |
title | A survey on table tolerances and couch overrides in radiotherapy |
title_full | A survey on table tolerances and couch overrides in radiotherapy |
title_fullStr | A survey on table tolerances and couch overrides in radiotherapy |
title_full_unstemmed | A survey on table tolerances and couch overrides in radiotherapy |
title_short | A survey on table tolerances and couch overrides in radiotherapy |
title_sort | survey on table tolerances and couch overrides in radiotherapy |
topic | Management and Profession |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690513/ https://www.ncbi.nlm.nih.gov/pubmed/27929512 http://dx.doi.org/10.1120/jacmp.v17i6.6261 |
work_keys_str_mv | AT chinskybonnie asurveyontabletolerancesandcouchoverridesinradiotherapy AT patelrakesh asurveyontabletolerancesandcouchoverridesinradiotherapy AT panfiljoshua asurveyontabletolerancesandcouchoverridesinradiotherapy AT surucumurat asurveyontabletolerancesandcouchoverridesinradiotherapy AT roeskejohnc asurveyontabletolerancesandcouchoverridesinradiotherapy AT chinskybonnie surveyontabletolerancesandcouchoverridesinradiotherapy AT patelrakesh surveyontabletolerancesandcouchoverridesinradiotherapy AT panfiljoshua surveyontabletolerancesandcouchoverridesinradiotherapy AT surucumurat surveyontabletolerancesandcouchoverridesinradiotherapy AT roeskejohnc surveyontabletolerancesandcouchoverridesinradiotherapy |