Evaluation of kidney motion and target localization in abdominal SBRT patients

The purpose of this study was to evaluate bilateral kidney and target translational/rotational intrafraction motion during stereotactic body radiation therapy treatment delivery of primary renal cell carcinoma and oligometastatic adrenal lesions for patients immobilized in the Elekta BodyFIX system....

Descripción completa

Detalles Bibliográficos
Autores principales: Sonier, Marcus, Chu, William, Lalani, Nafisha, Erler, Darby, Cheung, Patrick, Korol, Renee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690515/
https://www.ncbi.nlm.nih.gov/pubmed/27929514
http://dx.doi.org/10.1120/jacmp.v17i6.6406
Descripción
Sumario:The purpose of this study was to evaluate bilateral kidney and target translational/rotational intrafraction motion during stereotactic body radiation therapy treatment delivery of primary renal cell carcinoma and oligometastatic adrenal lesions for patients immobilized in the Elekta BodyFIX system. Bilateral kidney motion was assessed at midplane for 30 patients immobilized in a full‐body dual‐vacuum‐cushion system with two patients immobilized via abdominal compression. Intrafraction motion was assessed for 15 patients using kilovoltage cone‐beam computed tomography (kV‐CBCT) datasets ([Formula: see text]) correlated to the planning CT. Patient positioning was corrected for translational and rotational misalignments using a robotic couch in six degrees of freedom if setup errors exceeded 1 mm and 1°. Absolute bilateral kidney motion between inhale and exhale 4D CT imaging phases for left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions was [Formula: see text] , and [Formula: see text] , respectively. Residual setup error determined across CBCT type (pretreatment, intrafraction, and post‐treatment) for x (LR), y (SI), and z (AP) translations was [Formula: see text] , and [Formula: see text]; while for x (pitch), y (roll), and z (yaw) rotations was [Formula: see text] , and [Formula: see text] , respectively. Targets were localized to within 2.1 mm and 0.8° 95% of the time. The frequency of misalignments in the y direction was significant ([Formula: see text]) when compared to the x and z directions with no significant difference in translations between IMRT and VMAT. This technique is robust using BodyFIX for patient immobilization and reproducible localization of kidney and adrenal targets and daily CBCT image guidance for correction of positional errors to maintain treatment accuracy. PACS number(s): 87.55.‐x, 87.56.‐v, 87.56.Da