Cargando…

Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product

The purpose of this study is to evaluate the accuracy of automatic matching in cone‐beam computed tomography (CBCT) images relative to the reduction of total tube current–exposure time product (mAs) for the X‐ray imaging (XI) system. The CBCT images were acquired with the Catphan 504 phantom various...

Descripción completa

Detalles Bibliográficos
Autores principales: Won, Hui‐Su, Chung, Jin‐Beom, Choi, Byung‐Don, Park, Jin‐Hong, Hwang, Do‐Guwn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690535/
https://www.ncbi.nlm.nih.gov/pubmed/27929513
http://dx.doi.org/10.1120/jacmp.v17i6.6402
_version_ 1783279628980322304
author Won, Hui‐Su
Chung, Jin‐Beom
Choi, Byung‐Don
Park, Jin‐Hong
Hwang, Do‐Guwn
author_facet Won, Hui‐Su
Chung, Jin‐Beom
Choi, Byung‐Don
Park, Jin‐Hong
Hwang, Do‐Guwn
author_sort Won, Hui‐Su
collection PubMed
description The purpose of this study is to evaluate the accuracy of automatic matching in cone‐beam computed tomography (CBCT) images relative to the reduction of total tube current–exposure time product (mAs) for the X‐ray imaging (XI) system. The CBCT images were acquired with the Catphan 504 phantom various total mAs ratios such as 1.00, 0.83, 0.67, 0.57, and 0.50. For studying the automatic matching accuracy, the phantom images were acquired with a six‐dimensional shifting table. The image quality and correction of automatic matching were compared. With a decreasing total mAs ratio, the noise of the images increased and the low‐contrast resolution decreased, while the accuracy of the automatic matching did not change. Therefore, this study shows that a change of the total mAs while acquiring CBCT images has no effect on the automatic matching of Catphan 504 phantom in XI system. PACS number(s): 87.57.C‐, 87.57.Q‐
format Online
Article
Text
id pubmed-5690535
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56905352018-04-02 Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product Won, Hui‐Su Chung, Jin‐Beom Choi, Byung‐Don Park, Jin‐Hong Hwang, Do‐Guwn J Appl Clin Med Phys Technical Notes The purpose of this study is to evaluate the accuracy of automatic matching in cone‐beam computed tomography (CBCT) images relative to the reduction of total tube current–exposure time product (mAs) for the X‐ray imaging (XI) system. The CBCT images were acquired with the Catphan 504 phantom various total mAs ratios such as 1.00, 0.83, 0.67, 0.57, and 0.50. For studying the automatic matching accuracy, the phantom images were acquired with a six‐dimensional shifting table. The image quality and correction of automatic matching were compared. With a decreasing total mAs ratio, the noise of the images increased and the low‐contrast resolution decreased, while the accuracy of the automatic matching did not change. Therefore, this study shows that a change of the total mAs while acquiring CBCT images has no effect on the automatic matching of Catphan 504 phantom in XI system. PACS number(s): 87.57.C‐, 87.57.Q‐ John Wiley and Sons Inc. 2016-11-08 /pmc/articles/PMC5690535/ /pubmed/27929513 http://dx.doi.org/10.1120/jacmp.v17i6.6402 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Won, Hui‐Su
Chung, Jin‐Beom
Choi, Byung‐Don
Park, Jin‐Hong
Hwang, Do‐Guwn
Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title_full Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title_fullStr Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title_full_unstemmed Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title_short Accuracy of automatic matching of Catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
title_sort accuracy of automatic matching of catphan 504 phantom in cone‐beam computed tomography for tube current–exposure time product
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690535/
https://www.ncbi.nlm.nih.gov/pubmed/27929513
http://dx.doi.org/10.1120/jacmp.v17i6.6402
work_keys_str_mv AT wonhuisu accuracyofautomaticmatchingofcatphan504phantominconebeamcomputedtomographyfortubecurrentexposuretimeproduct
AT chungjinbeom accuracyofautomaticmatchingofcatphan504phantominconebeamcomputedtomographyfortubecurrentexposuretimeproduct
AT choibyungdon accuracyofautomaticmatchingofcatphan504phantominconebeamcomputedtomographyfortubecurrentexposuretimeproduct
AT parkjinhong accuracyofautomaticmatchingofcatphan504phantominconebeamcomputedtomographyfortubecurrentexposuretimeproduct
AT hwangdoguwn accuracyofautomaticmatchingofcatphan504phantominconebeamcomputedtomographyfortubecurrentexposuretimeproduct