Cargando…

Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis

Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsuang, Fon-Yih, Hsieh, Yueh-Ying, Kuo, Yi-Jie, Chen, Chia-Hsien, Lin, Feng-Huei, Chen, Chen-Sheng, Chiang, Chang-Jung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690668/
https://www.ncbi.nlm.nih.gov/pubmed/29145437
http://dx.doi.org/10.1371/journal.pone.0188034
_version_ 1783279652226203648
author Tsuang, Fon-Yih
Hsieh, Yueh-Ying
Kuo, Yi-Jie
Chen, Chia-Hsien
Lin, Feng-Huei
Chen, Chen-Sheng
Chiang, Chang-Jung
author_facet Tsuang, Fon-Yih
Hsieh, Yueh-Ying
Kuo, Yi-Jie
Chen, Chia-Hsien
Lin, Feng-Huei
Chen, Chen-Sheng
Chiang, Chang-Jung
author_sort Tsuang, Fon-Yih
collection PubMed
description Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stability for fusion but at a reduced stiffness. Tailored to degrade over a specific timeframe, biodegradable implants could potentially mitigate the drawbacks of conventional stiff constructs and reduce the loading on adjacent segments. Six finite element models were developed in this study to simulate a spine with and without fixators. The spinal fixators used both titanium rods and biodegradable rods. The models were subjected to axial loading and pure moments. The range of motion (ROM), disc stresses, and contact forces of facet joints at adjacent segments were recorded. A 3-point bending test was performed on the biodegradable rods and a dynamic bending test was performed on the spinal fixators according to ASTM F1717-11a. The finite element simulation showed that lumbar spinal fusion using biodegradable implants had a similar ROM at the fusion level as at adjacent levels. As the rods degraded over time, this produced a decrease in the contact force at adjacent facet joints, less stress in the adjacent disc and greater loading on the anterior bone graft region. The mechanical tests showed the initial average fatigue strength of the biodegradable rods was 145 N, but this decreased to 115N and 55N after 6 months and 12 months of soaking in solution. Also, both the spinal fixator with biodegradable rods and with titanium rods was strong enough to withstand 5,000,000 dynamic compression cycles under a 145 N axial load. The results of this study demonstrated that biodegradable rods may present more favourable clinical outcomes for lumbar fusion. These polymer rods could not only provide sufficient initial stability, but the loss in rigidity of the fixation construct over time gradually transfers loading to adjacent segments.
format Online
Article
Text
id pubmed-5690668
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56906682017-11-30 Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis Tsuang, Fon-Yih Hsieh, Yueh-Ying Kuo, Yi-Jie Chen, Chia-Hsien Lin, Feng-Huei Chen, Chen-Sheng Chiang, Chang-Jung PLoS One Research Article Interbody fusion with posterior instrumentation is a common method for treating lumbar degenerative disc diseases. However, the high rigidity of the fusion construct may produce abnormal stresses at the adjacent segment and lead to adjacent segment degeneration (ASD). As such, biodegradable implants are becoming more popular for use in orthopaedic surgery. These implants offer sufficient stability for fusion but at a reduced stiffness. Tailored to degrade over a specific timeframe, biodegradable implants could potentially mitigate the drawbacks of conventional stiff constructs and reduce the loading on adjacent segments. Six finite element models were developed in this study to simulate a spine with and without fixators. The spinal fixators used both titanium rods and biodegradable rods. The models were subjected to axial loading and pure moments. The range of motion (ROM), disc stresses, and contact forces of facet joints at adjacent segments were recorded. A 3-point bending test was performed on the biodegradable rods and a dynamic bending test was performed on the spinal fixators according to ASTM F1717-11a. The finite element simulation showed that lumbar spinal fusion using biodegradable implants had a similar ROM at the fusion level as at adjacent levels. As the rods degraded over time, this produced a decrease in the contact force at adjacent facet joints, less stress in the adjacent disc and greater loading on the anterior bone graft region. The mechanical tests showed the initial average fatigue strength of the biodegradable rods was 145 N, but this decreased to 115N and 55N after 6 months and 12 months of soaking in solution. Also, both the spinal fixator with biodegradable rods and with titanium rods was strong enough to withstand 5,000,000 dynamic compression cycles under a 145 N axial load. The results of this study demonstrated that biodegradable rods may present more favourable clinical outcomes for lumbar fusion. These polymer rods could not only provide sufficient initial stability, but the loss in rigidity of the fixation construct over time gradually transfers loading to adjacent segments. Public Library of Science 2017-11-16 /pmc/articles/PMC5690668/ /pubmed/29145437 http://dx.doi.org/10.1371/journal.pone.0188034 Text en © 2017 Tsuang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Tsuang, Fon-Yih
Hsieh, Yueh-Ying
Kuo, Yi-Jie
Chen, Chia-Hsien
Lin, Feng-Huei
Chen, Chen-Sheng
Chiang, Chang-Jung
Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title_full Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title_fullStr Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title_full_unstemmed Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title_short Assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: An in-vitro biomechanical evaluation and finite element analysis
title_sort assessment of the suitability of biodegradable rods for use in posterior lumbar fusion: an in-vitro biomechanical evaluation and finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690668/
https://www.ncbi.nlm.nih.gov/pubmed/29145437
http://dx.doi.org/10.1371/journal.pone.0188034
work_keys_str_mv AT tsuangfonyih assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT hsiehyuehying assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT kuoyijie assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT chenchiahsien assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT linfenghuei assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT chenchensheng assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis
AT chiangchangjung assessmentofthesuitabilityofbiodegradablerodsforuseinposteriorlumbarfusionaninvitrobiomechanicalevaluationandfiniteelementanalysis