Cargando…

Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom

The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see tex...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Zhiyue J., Seo, Youngseob, Babcock, Evelyn, Huang, Hao, Bluml, Stefan, Wisnowski, Jessica, Holshouser, Barbara, Panigrahy, Ashok, Shaw, Dennis W.W., Altman, Nolan, McColl, Roderick W., Rollins, Nancy K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690920/
https://www.ncbi.nlm.nih.gov/pubmed/27167268
http://dx.doi.org/10.1120/jacmp.v17i3.5972
_version_ 1783279693724647424
author Wang, Zhiyue J.
Seo, Youngseob
Babcock, Evelyn
Huang, Hao
Bluml, Stefan
Wisnowski, Jessica
Holshouser, Barbara
Panigrahy, Ashok
Shaw, Dennis W.W.
Altman, Nolan
McColl, Roderick W.
Rollins, Nancy K.
author_facet Wang, Zhiyue J.
Seo, Youngseob
Babcock, Evelyn
Huang, Hao
Bluml, Stefan
Wisnowski, Jessica
Holshouser, Barbara
Panigrahy, Ashok
Shaw, Dennis W.W.
Altman, Nolan
McColl, Roderick W.
Rollins, Nancy K.
author_sort Wang, Zhiyue J.
collection PubMed
description The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see text]) reached consensus on parameters for DTI and used the widely available ACR phantom. Tensor data were processed at one site. [Formula: see text] and eddy current distortions were assessed using grid line displacement on phantom Slice 5; signal‐to‐noise ratio (SNR) was measured at the center and periphery of the [Formula: see text] image; fractional anisotropy (FA) and mean diffusivity (MD) were assessed using phantom Slice 7. Variations of acquisition parameters and deviations from specified sequence parameters were recorded. Nonlinear grid line distortion was higher with linear shimming and could be corrected using the 2nd order shimming. Following image registration, eddy current distortion was consistently smaller than acquisition voxel size. SNR was consistently higher in the image periphery than center by a factor of 1.3–2.0. ROI‐based FA ranged from 0.007 to 0.024. ROI‐based MD ranged from [Formula: see text] to [Formula: see text]. Two sites had image void artifacts. The ACR phantom can be used to compare key quality measures of diffusion images acquired from multiple vendors at multiple sites. PACS number(s): 87.57.‐s, 87.19.lf
format Online
Article
Text
id pubmed-5690920
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56909202018-04-02 Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom Wang, Zhiyue J. Seo, Youngseob Babcock, Evelyn Huang, Hao Bluml, Stefan Wisnowski, Jessica Holshouser, Barbara Panigrahy, Ashok Shaw, Dennis W.W. Altman, Nolan McColl, Roderick W. Rollins, Nancy K. J Appl Clin Med Phys Medical Imaging The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see text]) reached consensus on parameters for DTI and used the widely available ACR phantom. Tensor data were processed at one site. [Formula: see text] and eddy current distortions were assessed using grid line displacement on phantom Slice 5; signal‐to‐noise ratio (SNR) was measured at the center and periphery of the [Formula: see text] image; fractional anisotropy (FA) and mean diffusivity (MD) were assessed using phantom Slice 7. Variations of acquisition parameters and deviations from specified sequence parameters were recorded. Nonlinear grid line distortion was higher with linear shimming and could be corrected using the 2nd order shimming. Following image registration, eddy current distortion was consistently smaller than acquisition voxel size. SNR was consistently higher in the image periphery than center by a factor of 1.3–2.0. ROI‐based FA ranged from 0.007 to 0.024. ROI‐based MD ranged from [Formula: see text] to [Formula: see text]. Two sites had image void artifacts. The ACR phantom can be used to compare key quality measures of diffusion images acquired from multiple vendors at multiple sites. PACS number(s): 87.57.‐s, 87.19.lf John Wiley and Sons Inc. 2016-05-08 /pmc/articles/PMC5690920/ /pubmed/27167268 http://dx.doi.org/10.1120/jacmp.v17i3.5972 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Wang, Zhiyue J.
Seo, Youngseob
Babcock, Evelyn
Huang, Hao
Bluml, Stefan
Wisnowski, Jessica
Holshouser, Barbara
Panigrahy, Ashok
Shaw, Dennis W.W.
Altman, Nolan
McColl, Roderick W.
Rollins, Nancy K.
Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title_full Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title_fullStr Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title_full_unstemmed Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title_short Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
title_sort assessment of diffusion tensor image quality across sites and vendors using the american college of radiology head phantom
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690920/
https://www.ncbi.nlm.nih.gov/pubmed/27167268
http://dx.doi.org/10.1120/jacmp.v17i3.5972
work_keys_str_mv AT wangzhiyuej assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT seoyoungseob assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT babcockevelyn assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT huanghao assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT blumlstefan assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT wisnowskijessica assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT holshouserbarbara assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT panigrahyashok assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT shawdennisww assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT altmannolan assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT mccollroderickw assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom
AT rollinsnancyk assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom