Cargando…
Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom
The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see tex...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690920/ https://www.ncbi.nlm.nih.gov/pubmed/27167268 http://dx.doi.org/10.1120/jacmp.v17i3.5972 |
_version_ | 1783279693724647424 |
---|---|
author | Wang, Zhiyue J. Seo, Youngseob Babcock, Evelyn Huang, Hao Bluml, Stefan Wisnowski, Jessica Holshouser, Barbara Panigrahy, Ashok Shaw, Dennis W.W. Altman, Nolan McColl, Roderick W. Rollins, Nancy K. |
author_facet | Wang, Zhiyue J. Seo, Youngseob Babcock, Evelyn Huang, Hao Bluml, Stefan Wisnowski, Jessica Holshouser, Barbara Panigrahy, Ashok Shaw, Dennis W.W. Altman, Nolan McColl, Roderick W. Rollins, Nancy K. |
author_sort | Wang, Zhiyue J. |
collection | PubMed |
description | The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see text]) reached consensus on parameters for DTI and used the widely available ACR phantom. Tensor data were processed at one site. [Formula: see text] and eddy current distortions were assessed using grid line displacement on phantom Slice 5; signal‐to‐noise ratio (SNR) was measured at the center and periphery of the [Formula: see text] image; fractional anisotropy (FA) and mean diffusivity (MD) were assessed using phantom Slice 7. Variations of acquisition parameters and deviations from specified sequence parameters were recorded. Nonlinear grid line distortion was higher with linear shimming and could be corrected using the 2nd order shimming. Following image registration, eddy current distortion was consistently smaller than acquisition voxel size. SNR was consistently higher in the image periphery than center by a factor of 1.3–2.0. ROI‐based FA ranged from 0.007 to 0.024. ROI‐based MD ranged from [Formula: see text] to [Formula: see text]. Two sites had image void artifacts. The ACR phantom can be used to compare key quality measures of diffusion images acquired from multiple vendors at multiple sites. PACS number(s): 87.57.‐s, 87.19.lf |
format | Online Article Text |
id | pubmed-5690920 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56909202018-04-02 Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom Wang, Zhiyue J. Seo, Youngseob Babcock, Evelyn Huang, Hao Bluml, Stefan Wisnowski, Jessica Holshouser, Barbara Panigrahy, Ashok Shaw, Dennis W.W. Altman, Nolan McColl, Roderick W. Rollins, Nancy K. J Appl Clin Med Phys Medical Imaging The purpose of this study was to explore the feasibility of assessing quality of diffusion tensor imaging (DTI) from multiple sites and vendors using American College of Radiology (ACR) phantom. Participating sites (Siemens [Formula: see text] , GE [Formula: see text] , and Philips [Formula: see text]) reached consensus on parameters for DTI and used the widely available ACR phantom. Tensor data were processed at one site. [Formula: see text] and eddy current distortions were assessed using grid line displacement on phantom Slice 5; signal‐to‐noise ratio (SNR) was measured at the center and periphery of the [Formula: see text] image; fractional anisotropy (FA) and mean diffusivity (MD) were assessed using phantom Slice 7. Variations of acquisition parameters and deviations from specified sequence parameters were recorded. Nonlinear grid line distortion was higher with linear shimming and could be corrected using the 2nd order shimming. Following image registration, eddy current distortion was consistently smaller than acquisition voxel size. SNR was consistently higher in the image periphery than center by a factor of 1.3–2.0. ROI‐based FA ranged from 0.007 to 0.024. ROI‐based MD ranged from [Formula: see text] to [Formula: see text]. Two sites had image void artifacts. The ACR phantom can be used to compare key quality measures of diffusion images acquired from multiple vendors at multiple sites. PACS number(s): 87.57.‐s, 87.19.lf John Wiley and Sons Inc. 2016-05-08 /pmc/articles/PMC5690920/ /pubmed/27167268 http://dx.doi.org/10.1120/jacmp.v17i3.5972 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Wang, Zhiyue J. Seo, Youngseob Babcock, Evelyn Huang, Hao Bluml, Stefan Wisnowski, Jessica Holshouser, Barbara Panigrahy, Ashok Shaw, Dennis W.W. Altman, Nolan McColl, Roderick W. Rollins, Nancy K. Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title | Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title_full | Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title_fullStr | Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title_full_unstemmed | Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title_short | Assessment of diffusion tensor image quality across sites and vendors using the American College of Radiology head phantom |
title_sort | assessment of diffusion tensor image quality across sites and vendors using the american college of radiology head phantom |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5690920/ https://www.ncbi.nlm.nih.gov/pubmed/27167268 http://dx.doi.org/10.1120/jacmp.v17i3.5972 |
work_keys_str_mv | AT wangzhiyuej assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT seoyoungseob assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT babcockevelyn assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT huanghao assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT blumlstefan assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT wisnowskijessica assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT holshouserbarbara assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT panigrahyashok assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT shawdennisww assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT altmannolan assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT mccollroderickw assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom AT rollinsnancyk assessmentofdiffusiontensorimagequalityacrosssitesandvendorsusingtheamericancollegeofradiologyheadphantom |