Cargando…
Calibration coefficients of dosimeters used in mammography for various target/filter combinations
A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X‐ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691010/ https://www.ncbi.nlm.nih.gov/pubmed/26699570 http://dx.doi.org/10.1120/jacmp.v16i6.5604 |
_version_ | 1783279706135592960 |
---|---|
author | Sekimoto, Michiharu Katoh, Yoh Katoh, Tsuguhisa |
author_facet | Sekimoto, Michiharu Katoh, Yoh Katoh, Tsuguhisa |
author_sort | Sekimoto, Michiharu |
collection | PubMed |
description | A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X‐ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X‐ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X‐ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber‐type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required. PACS number: 87.59.E‐ |
format | Online Article Text |
id | pubmed-5691010 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-56910102018-04-02 Calibration coefficients of dosimeters used in mammography for various target/filter combinations Sekimoto, Michiharu Katoh, Yoh Katoh, Tsuguhisa J Appl Clin Med Phys Medical Imaging A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X‐ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in mammography are generally calibrated with reference to the X‐ray quality of Mo/Mo or W/Al combinations, and it is unclear whether or not the X‐ray quality that is derived from other target/filter combinations will affect the calibration coefficients. In this paper, the calibration coefficients of different dosimeters were evaluated for target/filter combinations. For an ionization chamber‐type dosimeter, good energy dependence was found and the effect of the target/filter combination was small. However, for a semiconductor dosimeter, a large energy dependence was found, and different calibration coefficients that depended on the target/filter combination used were required. PACS number: 87.59.E‐ John Wiley and Sons Inc. 2015-11-08 /pmc/articles/PMC5691010/ /pubmed/26699570 http://dx.doi.org/10.1120/jacmp.v16i6.5604 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Sekimoto, Michiharu Katoh, Yoh Katoh, Tsuguhisa Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title | Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title_full | Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title_fullStr | Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title_full_unstemmed | Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title_short | Calibration coefficients of dosimeters used in mammography for various target/filter combinations |
title_sort | calibration coefficients of dosimeters used in mammography for various target/filter combinations |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691010/ https://www.ncbi.nlm.nih.gov/pubmed/26699570 http://dx.doi.org/10.1120/jacmp.v16i6.5604 |
work_keys_str_mv | AT sekimotomichiharu calibrationcoefficientsofdosimetersusedinmammographyforvarioustargetfiltercombinations AT katohyoh calibrationcoefficientsofdosimetersusedinmammographyforvarioustargetfiltercombinations AT katohtsuguhisa calibrationcoefficientsofdosimetersusedinmammographyforvarioustargetfiltercombinations |