Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation

This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calc...

Descripción completa

Detalles Bibliográficos
Autores principales: Zimmermann, Leonard W., Amoush, Ahmad, Wilkinson, Douglas A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691011/
https://www.ncbi.nlm.nih.gov/pubmed/26699577
http://dx.doi.org/10.1120/jacmp.v16i6.5659
_version_ 1783279706367328256
author Zimmermann, Leonard W.
Amoush, Ahmad
Wilkinson, Douglas A.
author_facet Zimmermann, Leonard W.
Amoush, Ahmad
Wilkinson, Douglas A.
author_sort Zimmermann, Leonard W.
collection PubMed
description This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantage [Formula: see text] seeds. In addition, the dosimetry parameters [Formula: see text] , and [Formula: see text] were calculated for the IsoAid Advantage model IAI‐125 [Formula: see text] seed and benchmarked against published data. Bebig Plaque Simulator (PS) v5.74 was used to calculate the central axis dose based on the AAPM Updated Task Group 43 (TG‐43U1) dose formalism. The calculated central axis dose from MC and PS was then compared. When the MC dosimetry parameters for the IsoAid Advantage [Formula: see text] seed were compared with the consensus values, Λ agreed with the consensus value to within 2.3%. However, much larger differences were found between MC calculated gL(r) and [Formula: see text] and the consensus values. The differences between MC‐calculated dosimetry parameters are much smaller when compared with recently published data. The differences between the calculated central axis absolute dose from MC and PS ranged from 5% to 10% for distances between 1 and 12 mm from the outer scleral surface. When the dosimetry parameters for the [Formula: see text] seed from this study were used in PS, the calculated absolute central axis dose differences were reduced by 2.3% from depths of 4 to 12 mm from the outer scleral surface. We conclude that PS adequately models the central dose profile of this plaque using its defaults for the IsoAid model IAI‐125 at distances of 1 to 7 mm from the outer scleral surface. However, improved dose accuracy can be obtained by using updated dosimetry parameters for the IsoAid model IAI‐125 [Formula: see text] seed. PACS number: 87.55.K‐
format Online
Article
Text
id pubmed-5691011
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-56910112018-04-02 Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation Zimmermann, Leonard W. Amoush, Ahmad Wilkinson, Douglas A. J Appl Clin Med Phys Radiation Oncology Physics This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantage [Formula: see text] seeds. In addition, the dosimetry parameters [Formula: see text] , and [Formula: see text] were calculated for the IsoAid Advantage model IAI‐125 [Formula: see text] seed and benchmarked against published data. Bebig Plaque Simulator (PS) v5.74 was used to calculate the central axis dose based on the AAPM Updated Task Group 43 (TG‐43U1) dose formalism. The calculated central axis dose from MC and PS was then compared. When the MC dosimetry parameters for the IsoAid Advantage [Formula: see text] seed were compared with the consensus values, Λ agreed with the consensus value to within 2.3%. However, much larger differences were found between MC calculated gL(r) and [Formula: see text] and the consensus values. The differences between MC‐calculated dosimetry parameters are much smaller when compared with recently published data. The differences between the calculated central axis absolute dose from MC and PS ranged from 5% to 10% for distances between 1 and 12 mm from the outer scleral surface. When the dosimetry parameters for the [Formula: see text] seed from this study were used in PS, the calculated absolute central axis dose differences were reduced by 2.3% from depths of 4 to 12 mm from the outer scleral surface. We conclude that PS adequately models the central dose profile of this plaque using its defaults for the IsoAid model IAI‐125 at distances of 1 to 7 mm from the outer scleral surface. However, improved dose accuracy can be obtained by using updated dosimetry parameters for the IsoAid model IAI‐125 [Formula: see text] seed. PACS number: 87.55.K‐ John Wiley and Sons Inc. 2015-11-08 /pmc/articles/PMC5691011/ /pubmed/26699577 http://dx.doi.org/10.1120/jacmp.v16i6.5659 Text en © 2015 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Zimmermann, Leonard W.
Amoush, Ahmad
Wilkinson, Douglas A.
Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title_full Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title_fullStr Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title_full_unstemmed Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title_short Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation
title_sort episcleral eye plaque dosimetry comparison for the eye physics ep917 using plaque simulator and monte carlo simulation
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5691011/
https://www.ncbi.nlm.nih.gov/pubmed/26699577
http://dx.doi.org/10.1120/jacmp.v16i6.5659
work_keys_str_mv AT zimmermannleonardw episcleraleyeplaquedosimetrycomparisonfortheeyephysicsep917usingplaquesimulatorandmontecarlosimulation
AT amoushahmad episcleraleyeplaquedosimetrycomparisonfortheeyephysicsep917usingplaquesimulatorandmontecarlosimulation
AT wilkinsondouglasa episcleraleyeplaquedosimetrycomparisonfortheeyephysicsep917usingplaquesimulatorandmontecarlosimulation