Cargando…
Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging
Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5695942/ https://www.ncbi.nlm.nih.gov/pubmed/29188092 http://dx.doi.org/10.1364/BOE.8.004933 |
_version_ | 1783280381155344384 |
---|---|
author | Qi, Ji He, Chao Elson, Daniel S. |
author_facet | Qi, Ji He, Chao Elson, Daniel S. |
author_sort | Qi, Ji |
collection | PubMed |
description | Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled. |
format | Online Article Text |
id | pubmed-5695942 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-56959422017-11-29 Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging Qi, Ji He, Chao Elson, Daniel S. Biomed Opt Express Article Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled. Optical Society of America 2017-10-10 /pmc/articles/PMC5695942/ /pubmed/29188092 http://dx.doi.org/10.1364/BOE.8.004933 Text en Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License (http://creativecommons.org/licenses/by/4.0/) . Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI. |
spellingShingle | Article Qi, Ji He, Chao Elson, Daniel S. Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title_full | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title_fullStr | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title_full_unstemmed | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title_short | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
title_sort | real time complete stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5695942/ https://www.ncbi.nlm.nih.gov/pubmed/29188092 http://dx.doi.org/10.1364/BOE.8.004933 |
work_keys_str_mv | AT qiji realtimecompletestokespolarimetricimagerbasedonalinearpolarizerarraycamerafortissuepolarimetricimaging AT hechao realtimecompletestokespolarimetricimagerbasedonalinearpolarizerarraycamerafortissuepolarimetricimaging AT elsondaniels realtimecompletestokespolarimetricimagerbasedonalinearpolarizerarraycamerafortissuepolarimetricimaging |