Cargando…

Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis

BACKGROUND: The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Co...

Descripción completa

Detalles Bibliográficos
Autores principales: Spranz, David M., Bruttel, Hendrik, Wolf, Sebastian I., Zeifang, Felix, Maier, Michael W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697353/
https://www.ncbi.nlm.nih.gov/pubmed/29162072
http://dx.doi.org/10.1186/s12891-017-1835-3
_version_ 1783280601474793472
author Spranz, David M.
Bruttel, Hendrik
Wolf, Sebastian I.
Zeifang, Felix
Maier, Michael W.
author_facet Spranz, David M.
Bruttel, Hendrik
Wolf, Sebastian I.
Zeifang, Felix
Maier, Michael W.
author_sort Spranz, David M.
collection PubMed
description BACKGROUND: The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS). METHODS: Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 shoulder joints. Stemless TSA was performed in 12 shoulder joints (group STEMLESS), third-generation stemmed TSA in 13 shoulder joints (group STEMMED). Functional results were documented using the CS. 3D-motion-analysis using the Heidelberg upper extremity model (HUX) was conducted to measure active maximum (ROM). RESULTS: The group STEMLESS achieved a CS of 67.9 (SD 12.0) points and the group STEMMED of 70.2 (SD 5.8 points) without significant difference between the groups (p = 0.925). The maximum ROM of the group STEMLESS, ascertained by 3-D-motion-analysis, was in forward flexion 125.5° (SD 17.2°), in extension 49.4° (SD 13.8°), in abduction 126.2° (SD 28.5°) and in external rotation 40.3° (SD 13.9°). The maximum ROM of the group STEMMED, also ascertained by 3-D-motion analysis, was in forward flexion 135.0° (SD 16.8°), in extension 47.2° (SD 11.5°), in abduction 136.3° (SD 24.2°) and in external rotation 40.1° (SD 12.2°). The maximum ROM of the STEMLESS group was lower in forward flexion and abduction, higher in extension and almost identical in external rotation. But there was no significant difference (forward flexion p = 0.174, extension p = 0.470, abduction p = 0.345, external rotation p = 0.978). CONCLUSION: Both types of shoulder prostheses achieve a similar and good active ROM and similar results in CS. TRIAL REGISTRATION: DRKS00013166, retrospectively registered, 11.10.2017
format Online
Article
Text
id pubmed-5697353
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-56973532017-12-01 Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis Spranz, David M. Bruttel, Hendrik Wolf, Sebastian I. Zeifang, Felix Maier, Michael W. BMC Musculoskelet Disord Research Article BACKGROUND: The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS). METHODS: Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 shoulder joints. Stemless TSA was performed in 12 shoulder joints (group STEMLESS), third-generation stemmed TSA in 13 shoulder joints (group STEMMED). Functional results were documented using the CS. 3D-motion-analysis using the Heidelberg upper extremity model (HUX) was conducted to measure active maximum (ROM). RESULTS: The group STEMLESS achieved a CS of 67.9 (SD 12.0) points and the group STEMMED of 70.2 (SD 5.8 points) without significant difference between the groups (p = 0.925). The maximum ROM of the group STEMLESS, ascertained by 3-D-motion-analysis, was in forward flexion 125.5° (SD 17.2°), in extension 49.4° (SD 13.8°), in abduction 126.2° (SD 28.5°) and in external rotation 40.3° (SD 13.9°). The maximum ROM of the group STEMMED, also ascertained by 3-D-motion analysis, was in forward flexion 135.0° (SD 16.8°), in extension 47.2° (SD 11.5°), in abduction 136.3° (SD 24.2°) and in external rotation 40.1° (SD 12.2°). The maximum ROM of the STEMLESS group was lower in forward flexion and abduction, higher in extension and almost identical in external rotation. But there was no significant difference (forward flexion p = 0.174, extension p = 0.470, abduction p = 0.345, external rotation p = 0.978). CONCLUSION: Both types of shoulder prostheses achieve a similar and good active ROM and similar results in CS. TRIAL REGISTRATION: DRKS00013166, retrospectively registered, 11.10.2017 BioMed Central 2017-11-21 /pmc/articles/PMC5697353/ /pubmed/29162072 http://dx.doi.org/10.1186/s12891-017-1835-3 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Spranz, David M.
Bruttel, Hendrik
Wolf, Sebastian I.
Zeifang, Felix
Maier, Michael W.
Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title_full Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title_fullStr Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title_full_unstemmed Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title_short Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
title_sort functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3d-motion-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697353/
https://www.ncbi.nlm.nih.gov/pubmed/29162072
http://dx.doi.org/10.1186/s12891-017-1835-3
work_keys_str_mv AT spranzdavidm functionalmidtermfollowupcomparisonofstemlesstotalshoulderprosthesesversusconventionalstemmedanatomicshoulderprosthesesusinga3dmotionanalysis
AT bruttelhendrik functionalmidtermfollowupcomparisonofstemlesstotalshoulderprosthesesversusconventionalstemmedanatomicshoulderprosthesesusinga3dmotionanalysis
AT wolfsebastiani functionalmidtermfollowupcomparisonofstemlesstotalshoulderprosthesesversusconventionalstemmedanatomicshoulderprosthesesusinga3dmotionanalysis
AT zeifangfelix functionalmidtermfollowupcomparisonofstemlesstotalshoulderprosthesesversusconventionalstemmedanatomicshoulderprosthesesusinga3dmotionanalysis
AT maiermichaelw functionalmidtermfollowupcomparisonofstemlesstotalshoulderprosthesesversusconventionalstemmedanatomicshoulderprosthesesusinga3dmotionanalysis