Cargando…
The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems
PURPOSE: Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant–abutment connection. The purposes of this study were to assess the performance of five brands (Straumann,...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697386/ https://www.ncbi.nlm.nih.gov/pubmed/29238725 http://dx.doi.org/10.1155/2017/8652720 |
_version_ | 1783280610496741376 |
---|---|
author | Erdem, Mehmet Ali Karatasli, Burcin Dinçer Kose, Onur Kose, Taha Emre Çene, Erhan Aydın Aya, Serhan Cankaya, Abdulkadir Burak |
author_facet | Erdem, Mehmet Ali Karatasli, Burcin Dinçer Kose, Onur Kose, Taha Emre Çene, Erhan Aydın Aya, Serhan Cankaya, Abdulkadir Burak |
author_sort | Erdem, Mehmet Ali |
collection | PubMed |
description | PURPOSE: Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant–abutment connection. The purposes of this study were to assess the performance of five brands (Straumann, Zimmer, Implant KA, Bredent, and Biohorizons) of wrench and to evaluate possible changes in applied torque values of aged wrenches. MATERIALS AND METHODS: Five new and aged wrenches that had been used approximately 250 times in a 1-year period were tested. The torque applied by friction- and spring-style wrenches was measured with a specially designed strain gauge indicator. Descriptive statistics, the one-sample t-test, and the independent-samples t-test were used to analyze values obtained from all torque wrenches. RESULTS: The accuracy of new and aged torque devices of all brands except Bredent differed significantly from the target values, but the mean values for aged and new wrenches did not differ significantly from each other (p > 0.05). Values for the spring- and friction-type torque wrenches deviated from the target values by 11.6% and 10.2%, respectively. CONCLUSION: The accuracy of aged torque wrenches is adequate for prosthetic screw tightening, but that of new torque wrenches is unsatisfactory and must be examined carefully before delivery. |
format | Online Article Text |
id | pubmed-5697386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-56973862017-12-13 The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems Erdem, Mehmet Ali Karatasli, Burcin Dinçer Kose, Onur Kose, Taha Emre Çene, Erhan Aydın Aya, Serhan Cankaya, Abdulkadir Burak Biomed Res Int Research Article PURPOSE: Friction-style and spring-style torque wrenches are used to tighten implant abutments and prosthetic screws. The mechanical stability of these torque wrenches is crucial for the implant–abutment connection. The purposes of this study were to assess the performance of five brands (Straumann, Zimmer, Implant KA, Bredent, and Biohorizons) of wrench and to evaluate possible changes in applied torque values of aged wrenches. MATERIALS AND METHODS: Five new and aged wrenches that had been used approximately 250 times in a 1-year period were tested. The torque applied by friction- and spring-style wrenches was measured with a specially designed strain gauge indicator. Descriptive statistics, the one-sample t-test, and the independent-samples t-test were used to analyze values obtained from all torque wrenches. RESULTS: The accuracy of new and aged torque devices of all brands except Bredent differed significantly from the target values, but the mean values for aged and new wrenches did not differ significantly from each other (p > 0.05). Values for the spring- and friction-type torque wrenches deviated from the target values by 11.6% and 10.2%, respectively. CONCLUSION: The accuracy of aged torque wrenches is adequate for prosthetic screw tightening, but that of new torque wrenches is unsatisfactory and must be examined carefully before delivery. Hindawi 2017 2017-11-07 /pmc/articles/PMC5697386/ /pubmed/29238725 http://dx.doi.org/10.1155/2017/8652720 Text en Copyright © 2017 Mehmet Ali Erdem et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Erdem, Mehmet Ali Karatasli, Burcin Dinçer Kose, Onur Kose, Taha Emre Çene, Erhan Aydın Aya, Serhan Cankaya, Abdulkadir Burak The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title | The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title_full | The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title_fullStr | The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title_full_unstemmed | The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title_short | The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems |
title_sort | accuracy of new and aged mechanical torque devices employed in five dental implant systems |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697386/ https://www.ncbi.nlm.nih.gov/pubmed/29238725 http://dx.doi.org/10.1155/2017/8652720 |
work_keys_str_mv | AT erdemmehmetali theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT karatasliburcin theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT dincerkoseonur theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT kosetahaemre theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT ceneerhan theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT aydınayaserhan theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT cankayaabdulkadirburak theaccuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT erdemmehmetali accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT karatasliburcin accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT dincerkoseonur accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT kosetahaemre accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT ceneerhan accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT aydınayaserhan accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems AT cankayaabdulkadirburak accuracyofnewandagedmechanicaltorquedevicesemployedinfivedentalimplantsystems |