Cargando…

High-intensity focused ultrasound ablation around the tubing

High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, l...

Descripción completa

Detalles Bibliográficos
Autores principales: Siu, Jun Yang, Liu, Chenhui, Zhou, Yufeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697872/
https://www.ncbi.nlm.nih.gov/pubmed/29161293
http://dx.doi.org/10.1371/journal.pone.0188206
_version_ 1783280688796008448
author Siu, Jun Yang
Liu, Chenhui
Zhou, Yufeng
author_facet Siu, Jun Yang
Liu, Chenhui
Zhou, Yufeng
author_sort Siu, Jun Yang
collection PubMed
description High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17–339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10–30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography.
format Online
Article
Text
id pubmed-5697872
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-56978722017-11-30 High-intensity focused ultrasound ablation around the tubing Siu, Jun Yang Liu, Chenhui Zhou, Yufeng PLoS One Research Article High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17–339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10–30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography. Public Library of Science 2017-11-21 /pmc/articles/PMC5697872/ /pubmed/29161293 http://dx.doi.org/10.1371/journal.pone.0188206 Text en © 2017 Siu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Siu, Jun Yang
Liu, Chenhui
Zhou, Yufeng
High-intensity focused ultrasound ablation around the tubing
title High-intensity focused ultrasound ablation around the tubing
title_full High-intensity focused ultrasound ablation around the tubing
title_fullStr High-intensity focused ultrasound ablation around the tubing
title_full_unstemmed High-intensity focused ultrasound ablation around the tubing
title_short High-intensity focused ultrasound ablation around the tubing
title_sort high-intensity focused ultrasound ablation around the tubing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5697872/
https://www.ncbi.nlm.nih.gov/pubmed/29161293
http://dx.doi.org/10.1371/journal.pone.0188206
work_keys_str_mv AT siujunyang highintensityfocusedultrasoundablationaroundthetubing
AT liuchenhui highintensityfocusedultrasoundablationaroundthetubing
AT zhouyufeng highintensityfocusedultrasoundablationaroundthetubing