Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease

Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM s...

Descripción completa

Detalles Bibliográficos
Autores principales: van den Hoven, Allard T., Mc-Ghie, Jackie S., Chelu, Raluca G., Duijnhouwer, Anthonie L., Baggen, Vivan J. M., Coenen, Adriaan, Vletter, Wim B., Dijkshoorn, Marcel L., van den Bosch, Annemien E., Roos-Hesselink, Jolien W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698365/
https://www.ncbi.nlm.nih.gov/pubmed/28631106
http://dx.doi.org/10.1007/s10554-017-1192-1
_version_ 1783280747073765376
author van den Hoven, Allard T.
Mc-Ghie, Jackie S.
Chelu, Raluca G.
Duijnhouwer, Anthonie L.
Baggen, Vivan J. M.
Coenen, Adriaan
Vletter, Wim B.
Dijkshoorn, Marcel L.
van den Bosch, Annemien E.
Roos-Hesselink, Jolien W.
author_facet van den Hoven, Allard T.
Mc-Ghie, Jackie S.
Chelu, Raluca G.
Duijnhouwer, Anthonie L.
Baggen, Vivan J. M.
Coenen, Adriaan
Vletter, Wim B.
Dijkshoorn, Marcel L.
van den Bosch, Annemien E.
Roos-Hesselink, Jolien W.
author_sort van den Hoven, Allard T.
collection PubMed
description Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson’s r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson’s r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.
format Online
Article
Text
id pubmed-5698365
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-56983652017-12-04 Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease van den Hoven, Allard T. Mc-Ghie, Jackie S. Chelu, Raluca G. Duijnhouwer, Anthonie L. Baggen, Vivan J. M. Coenen, Adriaan Vletter, Wim B. Dijkshoorn, Marcel L. van den Bosch, Annemien E. Roos-Hesselink, Jolien W. Int J Cardiovasc Imaging Original Paper Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson’s r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson’s r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality. Springer Netherlands 2017-06-19 2017 /pmc/articles/PMC5698365/ /pubmed/28631106 http://dx.doi.org/10.1007/s10554-017-1192-1 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Paper
van den Hoven, Allard T.
Mc-Ghie, Jackie S.
Chelu, Raluca G.
Duijnhouwer, Anthonie L.
Baggen, Vivan J. M.
Coenen, Adriaan
Vletter, Wim B.
Dijkshoorn, Marcel L.
van den Bosch, Annemien E.
Roos-Hesselink, Jolien W.
Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title_full Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title_fullStr Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title_full_unstemmed Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title_short Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
title_sort transthoracic 3d echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5698365/
https://www.ncbi.nlm.nih.gov/pubmed/28631106
http://dx.doi.org/10.1007/s10554-017-1192-1
work_keys_str_mv AT vandenhovenallardt transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT mcghiejackies transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT cheluralucag transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT duijnhouweranthoniel transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT baggenvivanjm transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT coenenadriaan transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT vletterwimb transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT dijkshoornmarcell transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT vandenboschannemiene transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease
AT rooshesselinkjolienw transthoracic3dechocardiographicleftheartchamberquantificationinpatientswithbicuspidaorticvalvedisease